Tools for Monitoring and Control of Bath Components

  • T. Ritzdorf
Chapter

Abstract

Maintaining constant chemical constituent concentrations in electrolytes is critical to ensure consistent process results in most deposition processes. In order to maintain consistent bath concentrations, it is important to be able to monitor the concentration of each constituent and to react to incorrect concentrations. The most efficient way to eliminate variation due to human factors and ensure consistent control is to automate the chemical management process [1].

Keywords

Electrochemical Activity Rotate Disk Electrode Cyclic Voltammetric Constituent Concentration Replenishment Rate 
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.

References

  1. 1.
    Ritzdorf, T. and Fulton, D.: Electrochemical deposition equipment, In: Datta, M.; Osaka, T.; and Schultze J. W., Eds. New Trends in Electrochemical Technology, Microelectronic Packaging, Francis and Taylor (CRC) 3, 471 (2005)Google Scholar
  2. 2.
    Taylor, T.; Ritzdorf, T.; Lindberg, F.; Carpenter, B.; and LeFebvre, M.: Electrolyte Composition Monitoring for Copper Interconnect Applications. Electrochemical Processing in ULSI Fabrication I and Interconnect and Contact Metallization: Materials, Processes, and Reliability, ECS, Pennington, NJ, 33 (1998)Google Scholar
  3. 3.
    Graham, L.; Ritzdorf, T.; and Lindberg, F.: Steady-State Chemical Analysis of Organic Suppressor Additives Used in Copper Plating Baths. Interconnect and Contact Metallization for ULSI, ECS, Pennington, NJ, PV 99(31), 143 (2000)Google Scholar
  4. 4.
    Robertson, P.; Tolmachev, Y. V.; and Fulton, D.: Galvanostatic Method for Quantification of Organic Suppressor and Accelerator Additives in Acid Copper Plating Baths. Morphological Evolution in Electrodeposition and Electrochemical Processing in ULSI Fabrication IV, ECS, Pennington, NJ, PV2001(8), 309 (2004)Google Scholar
  5. 5.
    Graham, L. W.; Taylor, T. C.; Ritzdorf, T. L.; Lindberg, F. A.; and Carpenter, B. C.: US Patent # 6,365,033, Methods for Controlling and/or Measuring Additive Concentration in an Electroplating Bath (2002)Google Scholar
  6. 6.
    Haak, R.; Ogden, C.; and Tench, D.: Cyclic Voltammetric Stripping Analysis of Acid Copper Sulfate Baths, Part 1: Polyether-Sulfide-Based Additives, Plating and Surface Finishing (1981)Google Scholar
  7. 7.
    Haak, R.; Ogden, C.; and Tench, D.: Cyclic Voltammetric Stripping Analysis of Acid Copper Sulfate Baths, Part 2: Sulfoniumalkanesulfonate-Based Additives, Plating and Surface Finishing (1982)Google Scholar
  8. 8.
    Freitag, W.; Ogden, C.; Tench, D.; and White, J.: Determination of the individual additive components in acid copper plating baths. Plat. Surf. Fin. 70(10), 55 (1983)Google Scholar
  9. 9.
    Bratin, P.: New Developments in Use of CVS for Analysis of Plating Solutions. Proceedings of AES Analytical Methods Symposium, Chicago, IL (1985)Google Scholar
  10. 10.
    Fisher, G. L. and Pellegrino, P. J.: The Use of Cyclic Pulse Voltammetric Stripping for Acid Copper Plating Bath Analysis, Plating and Surface Finishing (1988)Google Scholar
  11. 11.
    Haak, K.: Ion Chromatography in the Electroplating Industry. Plat. & Surf. Fin., September (1983)Google Scholar

Copyright information

© Springer Science+Business Media, LLC 2009

Authors and Affiliations

  1. 1.Semitool Inc.KalispellUSA

Personalised recommendations