Functional Hemodynamic Monitoring: A Personal Perspective

  • M. R. Pinsky
Conference paper


Hemodynamic monitoring is a central component of the overall management approach to the critically ill patient. Hemodynamic monitoring of critically ill patients has a dual function. First, it can be used to document hemodynamic stability and the lack of need for acute therapeutic interventions. Second, through monitoring we can measure variables and define the degree to which they vary from their baseline values. Thus, hemodynamic monitoring must be able to define both stability and change.


Chronic Obstructive Pulmonary Disease Hemodynamic Monitoring Stroke Volume Variation Spontaneous Breathing Trial Arterial Pulse Pressure 
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.


Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.


  1. 1.
    Bellomo R, Pinsky MR (1996) Invasive monitoring. In: Tinker J, Browne D, Sibbald W (eds) Critical Care — Standards, Audit and Ethics. Arnold Publishing Company, London, pp 82–104Google Scholar
  2. 2.
    Pinsky MR (2007) Hemodynamic evaluation and monitoring in the ICU. Chest 123: 2020–2029CrossRefGoogle Scholar
  3. 3.
    Michard F, Boussat S, Chemla D, et al (2000) Relation between respiratory changes in arterial pulse pressure and fluid responsiveness in septic patients with acute circulatory failure. Am J Respir Crit Care Med 162: 134–138PubMedGoogle Scholar
  4. 4.
    Pinsky MR, Payen D (2005) Functional hemodynamic monitoring. Crit Care 9: 566–572CrossRefPubMedGoogle Scholar
  5. 5.
    Hadian M, Pinsky MR (2007) Functional hemodynamic monitoring. Curr Opin Crit Care 13: 318–323CrossRefPubMedGoogle Scholar
  6. 6.
    Lopes MR, Oliveira MA, Pereira VO, Lemos IPB, Auler JO Jr, Michard F (2007) Goal-directed fluid management based on pulse pressure variation monitoring during high-risk surgery: a pilot randomized controlled trial. Crit Care 11:R100–107CrossRefPubMedGoogle Scholar
  7. 7.
    Pinsky MR (2002) Functional hemodynamic monitoring. Intensive Care Med 28: 386–388CrossRefPubMedGoogle Scholar
  8. 8.
    Monnet X, Rienzo M, Osman D, et al (2006) Response to leg raising predicts fluid responsiveness in critically ill. Crit Care Med 34: 1402–1407CrossRefPubMedGoogle Scholar
  9. 9.
    Pinsky MR, Vincent J-L (2005) Let us use the pulmonary artery catheter correctly and only when we need it. Crit Care Med 33: 1119–1122CrossRefPubMedGoogle Scholar
  10. 10.
    Skarda DE, Mulier KE, Myers DE, Taylor JH, Beilman GJ (2007) Dynamic near-infrared spectroscopy measurements in patients with severe sepsis. Shock 27: 348–353CrossRefPubMedGoogle Scholar
  11. 11.
    Gómez H, Torres A, Zenker S, et al (2008) Use of non-invasive NIRS during a vascular occlusion test to assess dynamic tissue O(2) saturation response. Intensive Care Med 34: 1600–1607CrossRefPubMedGoogle Scholar
  12. 12.
    Pinsky MR (1998) Controlled observations in critical care medicine: The therapeutic trial. Ann Acad Med Singapore 27: 387–396PubMedGoogle Scholar