Skip to main content

Setting the Operating Parameters

  • Chapter
  • First Online:
Basic Confocal Microscopy
  • 3697 Accesses

Abstract

The goal of this chapter is to systematically look at each decision made in obtaining images from a sample stained with single or multiple fluorochromes. While in this chapter most of the specific examples of choices made in setting instrument parameters are given by using images collected on a Zeiss LSM 510 META confocal microscope equipped with the following lasers: 405 nm blue diode, argon with peaks at 458, 477, 488 and 514 nm, 543 nm HeNe and 633 nm HeNe lasers, the basic choices made are the same regardless of the manufacturer of the system being used and the available hardware. When operating various confocal instruments, it is often simply a matter of identifying the terminology used, for example, pinhole versus iris or the name of a specific look up table (LUT), or finding where a particular software function is hidden in the multiple menus necessary to operate the system. Once the basic principals are understood, it is possible to quickly learn to operate any confocal microscope and to obtain publication quality images. Figure 9.1 illustrates a generalized flowchart that can be used to start an imaging session and to obtain the initial images. Detailed information on each of the steps involved is presented below.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 139.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 179.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  • Barlow, AL, MacLeod, A., Noppen, S., Sanderson, J., and Guerin, JG. 2010. Colocalization analysis in fluorescence micrographs: Verification of a more accurate calculation of Pearson’s Correlation Coefficient. Microsc Microanal 16(6):710–724.

    Google Scholar 

  • Boltes, S and Cordelieres, FP. 2006. A guided tour into subcellular colocalization analysis in light microscopy. J Microsc 224:213–232.

    Article  Google Scholar 

  • Manders, EMM., Verbeek, FJ., and Aten, JA. 1993. Measurement of co-localization of affects in dual-colour confocal images. J Microscopy 169:375–382.

    Article  Google Scholar 

  • North, AJ. 2006. Seeing is believing? A beginners guide to practical pitfalls in image acquisition. J Cell Biol 172:9–18.

    Article  PubMed  CAS  Google Scholar 

  • Pawley, J. 2000. The 39 steps: A cautionary tale of quantitative 3-D fluorescence microscopy. Biotechniques. 28:884–888.

    Google Scholar 

  • Zinchuk, V., Zinchuk, O., and Okada, T. 2007. Quantitative colocalization analysis of multicolor confocal immunofluorescence microscopy images: Pushing pixels to explore biological phenomena. Acta Histochem Cytochem. 40:101–111.

    Article  PubMed  CAS  Google Scholar 

  • Zucker, RM and Price, OT. 1999. Practical confocal microscopy and the evaluation of system performance. Methods 18:447–  458.

    Article  PubMed  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Robert L. Price .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2011 Springer Science+Business Media, LLC

About this chapter

Cite this chapter

Price, R.L. (2011). Setting the Operating Parameters. In: Price, R., Jerome, W. (eds) Basic Confocal Microscopy. Springer, New York, NY. https://doi.org/10.1007/978-0-387-78175-4_9

Download citation

Publish with us

Policies and ethics