Abstract

In the last decade, instrumentation for total knee arthroplasty (TKA) has improved the accuracy, reproducibility, and reliability of the procedure. In recent years, minimally invasive surgery (MIS) TKA introduced instrumentation that was reduced in size to fit within the smaller operative field. As the operative field becomes reduced in size, the impact and influence of technology becomes proportionately larger.1 The introduction of computer navigation with MIS is an attempt to improve the surgeon’s visibility in a reduced operative field. The intended goal is to improve the position of the resection guides and ultimately the position of the final components, in essence, providing improved visualization in the limited field. This new technology is an enhancement tool or enabler in MIS TKA because, after registration of the anatomic landmarks, the instruments are dynamically tracked with real-time feedback on the angle and depth of the femoral and tibial resection. Currently, there are two types of computer-navigated systems for TKA: imaged-guided and imageless systems. Image-guided systems rely on data from preoperative radiographs or computed tomography (CT) scans that are registered into the computer system. Imageless navigation systems eliminate the need for preoperative imaging and rely on the registration of intraoperative landmarks, and then compare the registered data with a library of anatomic specimens recorded within the computer databank. The next distinctive feature is the mode of instrument tracking, which can be either by optical line of sight with a series of arrays that are detected by an infrared camera, or an electromagnetic (EM) system that utilizes trackers that are attached to the bone and an EM field generator. Each computer navigation system has their proponents. Either way, advocates of computer-navigated surgery have reported in clinical studies that navigation has shown an improvement in the accuracy of component position within 3° of the desired position over conventional instrumentation.2,3 The computer relies on the registration of anatomic landmarks and interprets this data to create a three-dimensional (3D) virtual model of the knee. Refinements in the process of collecting the landmark data will create a more accurate virtual model and guidance system. The ideal system should be simple to use, accurate, and reliable without interfering with the operative field and should serve as an enabler in the limited operative field, reliably reporting the knee alignment and intraoperative kinematics.4

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 349.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Scuderi GR. Smart tools and total knee arthroplasty. Am J Orthop 36(95)Supplement: 8–10, 2007

    PubMed  Google Scholar 

  2. Alan RK, Shin MS, Tria AJ. Initial experience with electromagnetic navigation in total knee arthroplasty: a radiographic comparative study. J Knee Surg 20(2): 152–157, 2007

    PubMed  Google Scholar 

  3. Stiehl JB. Computer navigation in primary total knee arthroplasty. J Knee Surg 20(2): 158–164, 2007

    PubMed  Google Scholar 

  4. Scuderi GR. Computer navigation in total knee arthroplasty. Where are we and where are we heading. Am J Knee Surg 20(2): 151, 2007

    Google Scholar 

  5. DiGioia AM, Jaramaz B, Colgan BD. Computer assisted orthopedic surgery. Image guided and robotic assistive technologies. Clin Orthop Relat Res 354: 8–16, 1998

    Article  PubMed  Google Scholar 

  6. Specht LM, Koval KJ. Robotics and computer assisted orthopedic surgery. Bull Hosp Jt Dis 60: 168–172, 2001

    PubMed  Google Scholar 

  7. Adili A. Robotic assisted orthopedic surgery. Semin Laparosc Surg 11(2): 89–98, 2004

    PubMed  Google Scholar 

  8. Hurst KS, Phillips R, Viant WJ, etal. Review of orthopedic manipulator arms. Stud Health Technol Inform 50: 202–208, 1998

    CAS  PubMed  Google Scholar 

  9. Roche M. Changing the way surgeons plan and execute minimally invasive unicompartmental knee surgery. Orthopedic Product News July/August 2006

    Google Scholar 

  10. Surgano N. Computer assisted orthopedic surgery. J Orthop Sci 8(3): 442–448, 2003

    Article  Google Scholar 

  11. Kurtz S, Ong K, Lau E etal. Projection of primary and revision hip and knee arthroplasty in the United States 2005–2030. J Bone Joint Surg 89A: 780–785, 2007

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Giles R. Scuderi .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2010 Springer Science+Business Media, LLC

About this chapter

Cite this chapter

Kochhar, M., Scuderi, G.R. (2010). The Utility of Robotics in Total Knee Arthroplasty. In: Scuderi, G., Tria, A. (eds) Minimally Invasive Surgery in Orthopedics. Springer, New York, NY. https://doi.org/10.1007/978-0-387-76608-9_77

Download citation

  • DOI: https://doi.org/10.1007/978-0-387-76608-9_77

  • Published:

  • Publisher Name: Springer, New York, NY

  • Print ISBN: 978-0-387-76607-2

  • Online ISBN: 978-0-387-76608-9

  • eBook Packages: MedicineMedicine (R0)

Publish with us

Policies and ethics