Skip to main content

The influence of dose grid resolution on beam selection strategies in radiotherapy treatment design

  • Chapter
Optimization in Medicine

Part of the book series: Springer Optimization and Its Applications ((SOIA,volume 12))

Summary

The design of a radiotherapy treatment includes the selection of beam angles (geometry problem), the computation of a fluence pattern for each selected beam angle (intensity problem), and finding a sequence of configurations of a multileaf collimator to deliver the treatment (realization problem). While many mathematical optimization models and algorithms have been proposed for the intensity problem and (to a lesser extent) the realization problem, this is not the case for the geometry problem. In clinical practice, beam directions are manually selected by a clinician and are typically based on the clinician’s experience. Solving the beam selection problem optimally is beyond the capability of current optimization algorithms and software. However, heuristic methods have been proposed. In this paper we study the influence of dose grid resolution on the performance of these heuristics for a clinical case. Dose grid resolution refers to the spatial arrangement and size of dose calculation voxels. In particular, we compare the solutions obtained by the heuristics with those achieved by a clinician using a commercial planning system. Our results show that dose grid resolution has a considerable influence on the performance of most heuristics.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

eBook
USD 16.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 109.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 109.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2008 Springer Science+Business Media, LLC

About this chapter

Cite this chapter

Acosta, R., Ehrgott, M., Holder, A., Nevin, D., Reese, J., Salter, B. (2008). The influence of dose grid resolution on beam selection strategies in radiotherapy treatment design. In: Alves, C.J.S., Pardalos, P.M., Vicente, L.N. (eds) Optimization in Medicine. Springer Optimization and Its Applications, vol 12. Springer, New York, NY. https://doi.org/10.1007/978-0-387-73299-2_1

Download citation

Publish with us

Policies and ethics