Abstract
In this chapter various thermal, electronic, and chemical devices are described, as well as the construction and calibration of a spectroradiometer. A separate section is devoted to the measurement of very weak light, such as the ultraweak luminescence from living cells.
This is a preview of subscription content, log in via an institution.
Buying options
Tax calculation will be finalised at checkout
Purchases are for personal use only
Learn about institutional subscriptionsPreview
Unable to display preview. Download preview PDF.
References and Literature for Further Reading
Adick, H.-J., Schmidt, R. and Brauer, H.-D. (1989)A chemical actinometer for the wavelength range 610-670 nm. J. Photochem. Photobiol. 49A, 311–316.
Alfano, R.R. and Ockman, N. (1968)Methods for detecting weak light signals. J. Optical Soc. Am. 58, 90–95.
Allen, J.M., Allen, S.K. and Baertschi, W.W. (2000)2-Nitrobensaldehyde: a convenient UV-A and UV-B chemical actinometer for drug photostability testing. J. Pharmaceut. Biomed. Anal. 24, 167–178.
Bérces, A., Fekete, A., Gáspár, P., Grof, P., Rettberg, P., Hornedk, G. and Rontó, G. (1999)Biological UV dosimeters in the assessment of biological hazards from environmental radiation. J. Photochem. Photobiol. B Biol. 53, 36–43.
Björn, L.O. (1971)Simple methods for the calibration of light measuring equipment. Physiol. Plant. 25, 300–307.
Björn, L.O. (1995)Estimation of fluence rate from irradiance measurements with a cosine corrected sensor. J. Photochem. Photobiol. B Biol. 29, 179–183.
Björn, L.O. and Vogelmann, T.C. (1996)Quantifying light and ultraviolet radiation in plant biology. Photochem. Photobiol. 64, 403–406.
Evans, W.G. (2005)Infrared radiation sensors of Melanophila acuminata (Coleoptera: Buprestidae): a thermopneumatic model. Ann. Entomol. Soc. Am. 98, 738–746.
Goldstein, S. and Rabani, J. (2007)The ferrioalate and iodide-idodate actinometers in the UV region. J. Photochem. Photobiol. A: Chemistry, doi: 10.10/6/jjphotochem. 2007.06.006.
Hale, G.M. and Querry, M.R. (1973)Optical constants of water in the 200 nm to 200 μm wavelength region. Appl. Opt. 12, 555–563.
Hatchard, C.G. and Parker, C.A. (1956)A new sensitive actinometer. II. Potassium ferrioxalate as a standard chemical actinometer. Proc. Roy. Soc. A235, 518–536.
Jagger, J. (1967)Introduction to research in ultraviolet photobiology. Prentice-Hall, Englewood Cliffs, NJ.
Kuhn, H.J., Braslavsky, S.E. and Schmidt, R. (1989)Chemical actinometry. Pure Appl. Chem. 61, 187–210
Lee, J. and Seliger, H.H. (1964)Quantum yield of the ferrioxalate actinometer. J. Chem. Phys. 40, 519–523.
Marijnissen, J.P.A. and Star, W.M. (1987)Quantitative light dosimetry in vitro and in vivo. Lasers Med. Sci. 2, 235–242.
Mirón, A.S., Grima, E.M., Sevilla, J.M.F., Chisti, Y. and Camacho, F.G. (2000)Assessment of the photosynthetically active incident radiation on outdoor photobioreactors using oxalic acid/uranyl sulfate chemical actinometer. J. Appl. Phycol. 12, 385–394.
Namekata, N., Sasamori, S. and Inoue, S. (2006)800 MHz Single-photon detection at 1550-nm using an InGaAs/InP avalanche photodiode operated with a sine wave gating. Optics Express 14, 10043–10049.
Optronics Laboratories (1995)Improving integrating sphere design for near-perfect cosine response. Application Note (A9). Downloadable from http://www.olinet.com
Optronic Laboratories (2001)Standard spheres and sphere standards. Application Note (A15). Downloadable from http://www.olinet.com
Rahn, R.O. (1997)Potassium iodide as a chemical actinometer for 254 nm radiation: Use of iodate as an electron scavenger. Photochem. Photobiol. 66, 450.
Rolfe, J. and Moore, S.E. (1970)The efficient use of photomultiplier tubes for recording spectra. Appl. Optics 9, 63–71.
Ryer, A.D. (1997)Light measurement handbook. Newburyport: International Light, Inc., Technical Publications Dept. ISBN 0-9658356. Downloadable from http://www. intl-light.com/handbook/
Schmid, B. and Wehrli, C. (1995)Comparison of sun photometer calibration by use of the Langley technique and the standard lamp. Appl. Optics 34, 4500–4512.
Schmid, B., Spyak, P.R., Biggar, S.F., Wehrli, C., Sekler, J., Ingold, T., Mätzler, C. and Kämpfer, N. (1998)Evaluation of the applicability of solar and lamp radiometric calibrations of a precision sun photometer operating between 300 and 1025 nm. Appl. Optics 37, 3923–3941.
Schneider, W.E. and Young, R. Spectroradiometry methods. Application Note (A14), pp. 49. Orlando, FL: Optronics Laboratories. Downloadable from http://www. olinet.com
Seliger, H.H. and McElroy, W. (1965)Light: Physical and biological action. Academic Press, New York.
Skovsen, E., Snyder, J.W. and Ogilby, P.R. (2006)Two-photon singlet oxygen microscopy: The challenges working with single cells. Photochem. Photobiol. 82, 1187–1197.
Vogelmann, T.C. and Björn, L.O. (1984)Measurement of light gradients and spectral regime in plant tissue with a fiber optic probe. Physiol. Plant. 60, 361–368.
Wilson, S.R. and Forgan, B.W. (1995)In situ calibration technique for UV spectral measurements. Appl. Optics 34, 5475–5484.
Wegner, E.E. and Adamson, W.W. (1966)Photochemistry of complexions. III. Absolute quantum yields for the photolysis of some aqueous chromium (III) complexes. Chemical actinometry in the long wavelength visible region. J. Am. Chem. Soc. 88, 394–404.
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2008 Springer Science+Business Media, LLC
About this chapter
Cite this chapter
Björn, L.O. (2008). The Measurement of Light. In: Björn, L.O. (eds) Photobiology. Springer, New York, NY. https://doi.org/10.1007/978-0-387-72655-7_4
Download citation
DOI: https://doi.org/10.1007/978-0-387-72655-7_4
Publisher Name: Springer, New York, NY
Print ISBN: 978-0-387-72654-0
Online ISBN: 978-0-387-72655-7
eBook Packages: Biomedical and Life SciencesBiomedical and Life Sciences (R0)