Abstract
Crosslinked polyethylene appears to be a better hip bearing material than conventional polyethylene, but will it take us past the expected 20-year survival and into the anticipated need for 30-year survivors? Knowing that a sizeable percentage of Co-Cr femoral heads roughen in the patient, and that XLPE is sensitive to roughening, there are many doubts over the long-term clinical use of Co-Cr heads with XLPE cups. Wear studies at LLUMC suggest there is a likely cost for using larger Co-Cr head sizes in young and active patients, i.e. those requiring a larger femoral head to increase stability and reduce dislocation. Therefore, we believe that these higher activity patients with extended expectations will better benefit from alternative bearing surfaces such as ceramic on ceramic. In addition, there are four modes of wear generation, i.e. impingement, backside wear etc., however, we still know very little about these processes for XLPE, especially understanding changes in wear particle sizes and concentrations.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Donaldson T., Dickson T., Vinglass R., Bowsher J. G., Williams P., Clarke I.: Metal-metal bearings and large femoral heads for ultra-low wear with high stability. In Am Acad Ortho Surg, pp. SE003. Edited, Washington, D.C., 2005.
Clarke I., Tateiwa T., Manaka M., Shishido T., Gustafson A.: Clinical and laboratory perspectives on all-ceramic THR. In Trans 7th World Biomat Congr, pp. 222. Edited, Sydney, Australia, 2004.
Eickmann T., Green D. D., Donaldson T., Clarke I.: Backside wear in retrieved Hylamer liners. In Trans 50th Ann Meet Ortho Res Soc, pp.1461.Edited, San Francisco, California, 2004.
Clarke I., Donaldson T., Bowsher J. G., Nasser S., Takahashi T. Current concepts of metal-on-metal hip resurfacing. Ortho Clin North Am, 2005: In Press.
Heisel C., Silva M., dela Rosa M. A., Schmalzried T. P. Short-term in vivo wear of cross-linked polyethylene. J Bone Joint Surg Am, 2004, 86-A(4): 748–51.
McKellop H., Shen F. W., Lu B., Campbell P, Salovey R. Development of an extremely wear-resistant ultra high molecular weight polyethylene for total hip replacements. J Orthop Res, 1999, 17(2): 157–67.
Muratoglu O. K., Bragdon C. R., O’Connor D. O., Jasty M., Harris W. H. A novel method of cross-linking ultra-high-molecular-weight polyethylene to improve wear, reduce oxidation, and retain mechanical properties. Recipient of the 1999 HAP Paul Award. J Arthroplasty, 2001, 16(2): 149–60.
Muratoglu O. K., O’Connor D. O., Bragdon C. R., Delaney J., Jasty M., Harris W. H., Merrill E., Venugopalan P. Gradient crosslinking of UHMWPE using irradiation in molten state for total joint arthroplasty. Biomaterials, 2002, 23(3): 717–24.
Wang A., Essner A., Polineni V. K., Stark C., Dumbleton J. H. Lubrication and wear of ultra-high molecular weight polyethylene in total joint replacements. Tribology International, 1998, 31(1–3): 17–33.
Wroblewski B. M., Siney P. D., Fleming P. A. Low-friction arthroplasty of the hip using alumina ceramic and cross-linked polyethylene. A ten-year follow-up report. J Bone Joint Surg Br, 1999, 81(1): 54–5.
Charnley J., Kamangar A., Longfield M. D. The optimum size of prosthetic heads in relation to the wear of plastic sockets in total replacement of the hip. Med Biol Eng, 1969, 7(1): 31–9.
Beaule P. E., Dorey F. J., LeDuff M., Gruen T., Amstutz H. C. Risk factors affecting outcome of metal-on-metal surface arthroplasty of the hip. Clin Orthop, 2004, (418): 87–93.
Dowson D., Taheri S., Wallbridge N. C. The role of counterface imperfections in the wear of polyethylene. Wear, 1987, 119(3): 277–293.
Elfick A. P., Hall R. M., Pinder I. M., Unsworth A. The influence of femoral head surface roughness on the wear of ultrahigh molecular weight polyethylene sockets in cementless total hip replacement. J Biomed Mater Res, 1999, 48(5): 712–8.
McKellop H., Shen F. W., DiMaio W., Lancaster J. G. Wear of gamma-crosslinked polyethylene acetabular cups against roughened femoral balls. Clin Orthop, 1999, (369): 73–82.
Bauer T. W., Ming J., D’Antonio J. A., Morawa L. G. Abrasive three-body wear of polyethylene caused by broken multifilament cables of a total hip prosthesis. A report of these cases. J Bone Joint Surg Am, 1996, 78(8): 1244–7.
Scott D. L., Campbell P. A., McClung C. D., Schmalzried T. P. Factors contributing to rapid wear and osteolysis in hips with modular acetabular bearings made of Hylamer. J Arthroplasty, 2000, 15(1): 35–46.
Jasty M., Bragdon C. R., Lee K., Hanson A., Harris W. H. Surface damage to cobalt-chrome femoral head prostheses. J Bone Joint Surg Br, 1994, 76(1): 73–7.
Muratoglu, O. K.; Bragdon, C. R.; O’Connor, D. O.; Jasty, M.; Harris, W. H.; Gul, R.; and McGarry, F.: Unified wear model for highly crosslinked ultra-high molecular weight polyethylenes (UHMWPE). Biomaterials, 20(16): 1463–70, 1999.
McKellop, H.; Shen, F. W.; Lu, B.; Campbell, P.; and Salovey, R.: Effect of sterilization method and other modifications on the wear resistance of acetabular cups made of ultra-high molecular weight polyethylene. A hip-simulator study. J Bone Joint Surg Am, 82-A(12): 1708–25, 2000.
Good, V.; Ries, M.; Barrack, R. L.; Widding, K.; Hunter, G.; and Heuer, D.: Reduced wear with oxidized zirconium femoral heads. J Bone Joint Surg Am, 85-ASuppl 4: 105–10, 2003.
Oonishi H., Kadoya Y. Wear of high-dose gamma-irradiated polyethylene in total hip replacements. J Orthop Sci, 2000, 5(3): 223–8.
Grobbelaar C. J., du Plessis T. A., Marais F. The radiation improvement of polyethylene prostheses. A preliminary study. J Bone Joint Surg Br, 1978, 60-B(3): 370–4.
Bradford L., Baker D. A., Graham J., Chawan A., Ries M. D., Pruitt L. A. Wear and surface cracking in early retrieved highly cross-linked polyethylene acetabular liners. J Bone Joint Surg Am, 2004, 86-A(6): 1271–82.
Bradford L., Kurland R., Sankaran M., Kim H., Pruitt L. A., Ries M. D. Early failure due to osteolysis associated with contemporary highly cross-linked ultra-high molecular weight polyethylene. A case report. J Bone Joint Surg Am, 2004, 86-A(5): 1051–6.
McKellop H. A., Campbell P., Park S. H., Schmalzried T. P., Grigoris P., Amstutz H. C., Sarmiento A. The origin of submicron polyethylene wear debris in total hip arthroplasty. Clin Orthop, 1995, (311): 3–20.
Endo M. M., Barbour P. S. M., Barton D. C., Fisher J., Tipper J. L., Ingham E., Stone M. H.; Comparative wear and wear debris under three different counterface conditions of crosslinked and non-crosslinked ultra high molecular weight polyethylene, Biomed Mater Eng, 11(1), 23–35, 2001.
Essner A., Polineni V.K., Wang A., Stark C., Dumbleton J.H.; Effect of femoral head surface roughness and crosslinking on the wear of UHMWPE acetabular inserts, Trans Society Biomaterials, 21, 4, 1998.
McKellop H., Shen F., DiMaio W., Lancaster J.G.; Wear of gamma-crosslinked polyethylene acetabular cups against roughened femoral balls, J. Clinical Orthop. Related Res., 369, 73–82, 1999.
Good V., Ries M., Barrack R. L., Widding K., Hunter G., Heuer D. Reduced wear with oxidized zirconium femoral heads. J Bone Joint Surg Am, 2003, 85-ASuppl 4: 105–10.
Bowsher J. G., Hussain A., Elfick A. P., Green S. S., Shelton J. C.: Severe patient activity substantially increased the number of submicron-sized wear particles in a XLPE-on-metal hip simulator study. In Trans 51st Ann Meet Ortho Res Soc, 2005, pp. 12. Edited, Washington D. C.
Yamamoto K., Clarke I. C., Masaoka T., Oonishi H., Williams P. A., Good V. D., Imakiire A. Microwear phenomena of ultrahigh molecular weight polyethylene cups and debris morphology related to gamma radiation dose in simulator study. J Biomed Mater Res, 2001, 56(1): 65–73.
Green T. R., Fisher J., Stone M., Wroblewski B. M., Ingham E. Polyethylene particles of a ‘critical size’ are necessary for the induction of cytokines by macrophages in vitro. Biomaterials, 1998, 19(24): 2297–302.
Schmalzreid T. P., Clarke I. C., McKellop H. Bearing Surfaces. In The Adult Hip, Vol. 247–265. Edited by Callaghan, J. J.; Rosenberg, A.; and Rubash, H., Lippincott-Raven Press, 1998.
Bowsher J.G., Shelton J.C.; A hip simulator study of the influence of patient activity level on wear of crosslinked polyethylene under smooth and roughened femoral heads, Wear, 250, 167–179, 2001.
McKellop H. A., Campbell P., Park S. H., Schmalzried T. P., Grigoris P., Amstutz H. C., Sarmiento A. The origin of submicron polyethylene wear debris in total hip arthroplasty. Clin Orthop, 1995, (311): 3–20.
Bauer T. W., Taylor S. K., Jiang M., Medendorp S. V. An indirect comparison of third-body wear in retrieved hydroxyapatite-coated, porous, and cemented femoral components. Clin Orthop, 1994, (298): 11–8.
Rights and permissions
Copyright information
© 2005 Steinkopff Verlag Darmstadt
About this paper
Cite this paper
Donaldson, T., Massihi, A., Bowsher, J.G., Clarke, I.C. (2005). Co-Cr Head Roughness and its Effect on Wear of UHMWPE and XLPE Cups. In: Bioceramics and Alternative Bearings in Joint Arthroplasty. Ceramics in Orthopaedics. Steinkopff. https://doi.org/10.1007/3-7985-1540-9_9
Download citation
DOI: https://doi.org/10.1007/3-7985-1540-9_9
Publisher Name: Steinkopff
Print ISBN: 978-3-7985-1518-5
Online ISBN: 978-3-7985-1540-6
eBook Packages: MedicineMedicine (R0)