Metal/metal articulations made from Cobalt-Chromium-Molybdenum (CoCrMo) alloys have been re-introduced more than 15 years ago. The Clinical mid term outcomes as well as the in vitro-testing results are very encouraging. Since the mid nineties of the last century lymphocytic infiltrations in the retrieval tissues around metal/metal arthroplasties have been observed. This phenomenon occurs at a low incidence around different metal systems.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Anthony D. C., Miller K. M., Fearn S., Townsend M. J., Opdenakker G., Wells G. M., Clements J. M., Chandler S., Gearing A. J., Perry V. H. Matrix metalloproteinase expression in an experimentally-induced DTH model of multiple sclerosis in the rat CNS. J Neuroimmunol 1998;87:62–72.
Chan F. W., Bobyn J. D., Medley J. B., Krygier J. J., Yue S., Tanzer M. Engineering issues and wear performance of metal on metal hip implants. Clin Orthop. 1999;333:96–107.
Doorn P. F., Mirra J. M., Campbell P. A., Amstutz H. C. Tissue reaction to metal on metal total hip prostheses. Clin Orthop. 1996;329S:S187–205.
Doorn P. F., Campbell P. A., Worrall J., Benya P. D., McKellop H. A., Amstutz H. C. Metal wear particle characterization from metal on metal total hip replacements: transmission electron microscopy study of periprosthetic tissues and isolated particles. J Biomed Mater Res 1998 Oct;42:103–11.
Haynes D. R., Crotti T. N., Haywood M. R. Corrosion of and changes in biological effects of cobalt chrome alloy and 316L stainless steel prosthetic particles with age. J Biomed Mater Res. 2000;49:167–75.
Howie D. W., Rogers S. D., McGee M. A., Haynes D. R. Biologic effects of cobalt chrome in cell and animal models. Clin Orthop. 1996;329S: S217–32.
Jacobs J. J., Urban R. M., Gilbert I. L., Skipor A. K., Black J., Jasty M., Galante J. O., Local und distant products from modularity. Clin Orthop 1995;319:94–105
Lohmann C. H., Buchhorn G. H., Flury R., Koester G., Willert H. G.. Metal/Metal bearings and hypersensitivity in artificial hip joints. Proc Annual Meeting EORS 2003, Helsinki, Finland
Rieker C. B., Köttig P., Schön R., Windler M., Wyss U. P. Clinical wear performance of metal-on-metal hip arthroplasties. In: Jacobs J.J., Craig T. L. (eds.) Alternative Bearng Surfaces in Total Joint Replacement. ASTM STP 1346, pp 144–56, 1998.
Rieker C. B., Weber H., Schön R., Windler M., Wyss U.P. Development of the Metasul articulation, In: Metasul — A Metal-on-Metal Bearing. Rieker C., Windler M., Wyss U. (eds.) pp 15–22, H.Huber Bern 1999.
Semlitsch M., Streicher R. M., Weber H. VerschleißBverhalten von Pfannen und Kugeln aus CoCrMo — GußBlegierung bei langzeitig implantierten Ganzmetall-Hüftprothesen. Orthopäde. 1989;18:377–81.
Semlitsch M., Willert H. G. Clinical wear behavior of UHMW polyethylene cups paired with metal and ceramic ball heads in comparison to metal-on-metal pairings of hip joint replacements. Acta Chir Orthop Traumatol Cechosl; 1996;63:68–82.
Streicher R. M., Semlitsch M., Schön R., Weber H. Metal-on-metal articulation for artificial hip joints: Laboratory study and clinical results. Proc Inst Mech Eng [H]; 1996; 210:223–32.
Streicher R. M., Schön R., Semlitsch M. Untersuchung des tribologischen Verhaltens von Metall/Metall — Kombinationen für künstliche Hüftgelenke. Biomed Technik. 1990;35:107–11.
Streicher R. M. Metal-on-metal articulation in total hip arthroplasty: the case for using metal-on-metal. J Arthroplasty 1998;13:343–5; discussion 345-6.
Weber B. G. Metall-Metall-Totalprothese des Hüftgelenkes: Zurück in die Zukunft. Z. Orthop. 1992;130:306–9.
Willert H. G., Semlitsch M. Tissue reactions to plastic and metallic wear products of joint endoprostheses. In: Gschwend N, Debrunner HU (eds.) Total Hip Endoprosthesis. Hans Huber Verlag, Bern 1976: 205–39.
Willert H. G., Semlitsch M. Reactions of the articular capsule to wear products of artificial joint prostheses. J Biomed Mater Res. 1977;11:157–64.
Willert H. G., Buchhorn G. H., Hess T. Die Bedeutung von Abrieb und Materialermüdung bei der Prothesenlockerung an der Hüfte. Orthopäde. 1989;18:350–69.
Willert H. G., Buchhorn G. H., Göbel D., Köster G., Schaffner S., Schenk R., Semlitsch M. Wear behavior and histopathology of classic cemented metal on metal hip prostheses. Clin Orthop, 1996;329S: S160–186.
Willert H. G., Buchhorn G. H. The biology of the loosening of implants. In: European Instuctional Course Lectures Vol.4. Jacob R. Fulford P. Horan F. (eds.) The British Society of Bone and Joint Surgery, London; 1999: 58–82.
Willert H. G., Bucchorn G. H., Fayazzi A., Flury R., Windler M., Koester G., Lohmann C. H.: Metal/metal bearings and hypersensitivity in artifical hip joint — a clinical and histomorphological study. J Bone Joint Surg-A, 2005;87-A), 28–36
Rights and permissions
Copyright information
© 2005 Steinkopff Verlag Darmstadt
About this paper
Cite this paper
Lohmann, C. (2005). Can Metal-Metal Total Hip Arthroplasty induce Hypersensitivity reactions?. In: Bioceramics and Alternative Bearings in Joint Arthroplasty. Ceramics in Orthopaedics. Steinkopff. https://doi.org/10.1007/3-7985-1540-9_5
Download citation
DOI: https://doi.org/10.1007/3-7985-1540-9_5
Publisher Name: Steinkopff
Print ISBN: 978-3-7985-1518-5
Online ISBN: 978-3-7985-1540-6
eBook Packages: MedicineMedicine (R0)