Conclusions
Pulse pressure analysis has an important role in the management of critically ill patients. There are currently several devices available that are less invasive and serve to provide continuous and accurate measurements of cardiac output. PiCCO is the oldest device and has been validated in several clinical situations. LiDCO is more recent and has also been validated, with more studies to follow. PRAM and FloTrac are very new devices that have the advantage of not requiring calibration and being quick and easy to use. There is evidence validating PRAM and results on the use of FloTrac are expected in the near future. There has been much criticism about the use of the PAC recently. It is our vision that pulse pressure analysis will be implemented in clinical protocols to change management and outcome in critically ill patients.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Darovic GO, Vanriper S (1995) Arterial pressure recording. In: Darovic GO (ed) Hemodynamic Monitoring. 2nd ed. WB Sauners, Philadelphia, pp 177–210
Nichols WW, O’Rourke MF (1990) McDonald’s Blood Flow in Arteries. 3rd edition. Lea & Febiger, Philadelphia, pp 251–269
Rhodes A, Sunderland R (2005) Arterial pulse power analysis: The LiDCOTMplus System. In: Pinsky MR, Payen D (eds) Functional Hemodynamic Monitoring. Springer, Heidelberg, pp 183–192
Frank O (1899) Die Grundform des Ateriellen Pulses. Z Biol 37:483
Erlanger J, Hooker DR (1994) An experimental study of blood pressure and of pulse pressure in man. John Hopkins Hospital Records 12:145–378
Wesseling KH, de Wit B, Weber AP (1983) A simple device for the continuous measurement of cardiac output. Adv Cardiovasc Phys 5:1–52
Jansen JRC, van den Berg PCM (2005) Cardiac output by thermodilution and arterial pulse contour techniques. In: Pinsky MR, Payen D (eds) Functional Hemodynamic Monitoring. Springer, Heidelberg, pp 135–152
Jansen JRC, Wesseling KH, Settels JJ, Schreuder JJ (1990) Continuous cardiac output monitoring by pulse contour during cardiac surgery. Eur Heart J 11:26–32
Wesseling KH, Jansen JRC, Settels JJ, Schreuder JJ (1993) Computation of aortic flow from pressure in humans using a nonlinear, three element model. J Appl Physiol 74:2566–2573
Jansen JRC, Schreuder KK, Mulier JP, Smith NT, Settels JJ, Wesseling KH (2001) A comparison of cardiac output derived from the arterial pressure wave against thermodilution in cardiac surgery patients. Br J Anaesth 87:212–222
Jellema WT, Wesseling KH, Groeneveld ABJ, Stouteribeek CP, Thijs LG, van Lieshout JJ (1999) Continuous cardiac output in septic shock by simulating a model of the artic input impedance. A comparison with bolus injection thermodilution. Anesthesiology 90:1317–1328
Codje O, Hoeke K, Goetz AE, et al (2002) Reliability of a new algorithm for continous cardiac determination by pulse-contour analysis during hemodynamic instability. Crit Care Med 30:52–58
Buhre W, Weyland A, Kazmaier S, et al (1999) Comparison of cardiac output assessed by pulse contour analysis and thermodilution in patients undergoing minimally invasive direct coronary artery bypass grafting. J Cardiothorac Vasc Anesth 13:437–440
Zollner C, Briegel J, Kilger E, Haller M (1998) Retrospective analysis of transpulmonary and pulmonary arterial measurement of cardiac output in ARDS patients. Anaesthesist 47:912–917
Goedje O, Hoeke K, Lichtwarck-Aschoff M, et al (1999) Continous cardiac output by femoral artery thermodilution calibrated pulse contour analysis: Comparison with pulmonary artery thermodilution. Crit Care Med 27:2407–2412
Zollner C, Haller M, Weis M, et al (2000) Beat-to-beat measurement of cardiac output by intravascular pulse contour analysis: A prospective criterion standard study in patients after cardiac surgery. J Cardiothorac Vasc Anesth 14:125–129
Della Rocca G, Costa MG, Pompei L, Coccia C, Pietropaoli P (2002) Continous and intermittent cardiac output measurement: pulmonary artery catheter versus aortic transpulmonary technique. Br J Anaesth 88:350–356
Della Rocca G, Costa MG, Coccia C, et al (2003) Cardiac output monitorino: aortic transpulmonary thermodilution and pulse contour analysis agree with standard thermodilution methods in patients undergoing lung transplantation. Can J Anaesth 50:707–711
Rodig G, Prasser C, Keyl C, Liebold A, Hobbhahn (1999) Continuous cardiac output measurement: Pulse contour analysis versus thermodilution technique in cardiac surgical patients. Br J Anaesth 82:525–530
Hamilton TT, Huber LM, Jessen ME (2002) PulseCO: a less-invasive method to monitor cardiac output from arterial pressure after cardiac surgery Ann Thorac Surg 74:S1408–S1412
Tsutsui M, Mori T, Aramaki Y, Fukuda I, Kazama T (2004) A comparison of two methods for continuous cardiac output measurement: PulseCO VS CCO. Masui 53:929–933
Jonas MM, Tanser SJ (2002) Lithium dilution measurement of cardiac output and arterial pulse waveform analysis: an indicator dilution calibrated beat-by-beat system for continous estimation of cardiac output. Curr Opin Crit Care 8:257–261
Pittman J, Bar-Yosef S, Sumping J, Sherwood M, Mark J (2005) Continuous cardiac output monitoring with pulse contour analysis: A comparison with lithium indicator dilution cardiac output measurement. Crit Care Med 33:2015–2021
Romano SM, Pistolesi M (2002) Assessment of cardiac output from systemic arterial pressure in humans. Crit Care Med 30:1834–1841
Giomarelli P, Biagioli B, Scolletta S (2004) Cardiac output monitorino by pressare recording analytical method in cardiac surgery. Eur J Cardiothorac Surg 26:515–520
Scolletta S, Romano SM, Biagioli B, Capannini G, Giomarelli P (2005) Pressure recording analytical method (PRAM) for measurement of cardiac output during various haemodynamic states. Br J Anaest 95:159–165
Langewouters GJ, Wesseling KH, Goedhard WJ (1984) The static elastic properties of 45 human thoracic and 20 abdominal aortas in vitro and the parameters of a new model. J Biomech 17:425–435
Manecke GR, Peterson M, Auger W (2004) Cardiac output determination using arterial pulse: a comparison of a novel algorithm against continuous and intermittent thermodilution. Crit Care Med 32:A43 (abst)
McGee W, Horswell JL, Janvier G (2005) Validation of a continuous cardiac output measurement using arterial pressure waveforms. Crit Care 9:S24 (abst)
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2006 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Cecconi, M., Wilson, J., Rhodes, A. (2006). Pulse Pressure Analysis. In: Vincent, JL. (eds) Yearbook of Intensive Care and Emergency Medicine. Yearbook of Intensive Care and Emergency Medicine, vol 2006. Springer, Berlin, Heidelberg. https://doi.org/10.1007/3-540-33396-7_17
Download citation
DOI: https://doi.org/10.1007/3-540-33396-7_17
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-540-30155-4
Online ISBN: 978-3-540-33396-8
eBook Packages: MedicineMedicine (R0)