Conclusions

Pulse pressure analysis has an important role in the management of critically ill patients. There are currently several devices available that are less invasive and serve to provide continuous and accurate measurements of cardiac output. PiCCO is the oldest device and has been validated in several clinical situations. LiDCO is more recent and has also been validated, with more studies to follow. PRAM and FloTrac are very new devices that have the advantage of not requiring calibration and being quick and easy to use. There is evidence validating PRAM and results on the use of FloTrac are expected in the near future. There has been much criticism about the use of the PAC recently. It is our vision that pulse pressure analysis will be implemented in clinical protocols to change management and outcome in critically ill patients.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 139.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Darovic GO, Vanriper S (1995) Arterial pressure recording. In: Darovic GO (ed) Hemodynamic Monitoring. 2nd ed. WB Sauners, Philadelphia, pp 177–210

    Google Scholar 

  2. Nichols WW, O’Rourke MF (1990) McDonald’s Blood Flow in Arteries. 3rd edition. Lea & Febiger, Philadelphia, pp 251–269

    Google Scholar 

  3. Rhodes A, Sunderland R (2005) Arterial pulse power analysis: The LiDCOTMplus System. In: Pinsky MR, Payen D (eds) Functional Hemodynamic Monitoring. Springer, Heidelberg, pp 183–192

    Chapter  Google Scholar 

  4. Frank O (1899) Die Grundform des Ateriellen Pulses. Z Biol 37:483

    Google Scholar 

  5. Erlanger J, Hooker DR (1994) An experimental study of blood pressure and of pulse pressure in man. John Hopkins Hospital Records 12:145–378

    Google Scholar 

  6. Wesseling KH, de Wit B, Weber AP (1983) A simple device for the continuous measurement of cardiac output. Adv Cardiovasc Phys 5:1–52

    Google Scholar 

  7. Jansen JRC, van den Berg PCM (2005) Cardiac output by thermodilution and arterial pulse contour techniques. In: Pinsky MR, Payen D (eds) Functional Hemodynamic Monitoring. Springer, Heidelberg, pp 135–152

    Chapter  Google Scholar 

  8. Jansen JRC, Wesseling KH, Settels JJ, Schreuder JJ (1990) Continuous cardiac output monitoring by pulse contour during cardiac surgery. Eur Heart J 11:26–32

    PubMed  Google Scholar 

  9. Wesseling KH, Jansen JRC, Settels JJ, Schreuder JJ (1993) Computation of aortic flow from pressure in humans using a nonlinear, three element model. J Appl Physiol 74:2566–2573

    CAS  PubMed  Google Scholar 

  10. Jansen JRC, Schreuder KK, Mulier JP, Smith NT, Settels JJ, Wesseling KH (2001) A comparison of cardiac output derived from the arterial pressure wave against thermodilution in cardiac surgery patients. Br J Anaesth 87:212–222

    Article  CAS  PubMed  Google Scholar 

  11. Jellema WT, Wesseling KH, Groeneveld ABJ, Stouteribeek CP, Thijs LG, van Lieshout JJ (1999) Continuous cardiac output in septic shock by simulating a model of the artic input impedance. A comparison with bolus injection thermodilution. Anesthesiology 90:1317–1328

    Article  CAS  PubMed  Google Scholar 

  12. Codje O, Hoeke K, Goetz AE, et al (2002) Reliability of a new algorithm for continous cardiac determination by pulse-contour analysis during hemodynamic instability. Crit Care Med 30:52–58

    Article  Google Scholar 

  13. Buhre W, Weyland A, Kazmaier S, et al (1999) Comparison of cardiac output assessed by pulse contour analysis and thermodilution in patients undergoing minimally invasive direct coronary artery bypass grafting. J Cardiothorac Vasc Anesth 13:437–440

    Article  CAS  PubMed  Google Scholar 

  14. Zollner C, Briegel J, Kilger E, Haller M (1998) Retrospective analysis of transpulmonary and pulmonary arterial measurement of cardiac output in ARDS patients. Anaesthesist 47:912–917

    Article  CAS  PubMed  Google Scholar 

  15. Goedje O, Hoeke K, Lichtwarck-Aschoff M, et al (1999) Continous cardiac output by femoral artery thermodilution calibrated pulse contour analysis: Comparison with pulmonary artery thermodilution. Crit Care Med 27:2407–2412

    Article  CAS  PubMed  Google Scholar 

  16. Zollner C, Haller M, Weis M, et al (2000) Beat-to-beat measurement of cardiac output by intravascular pulse contour analysis: A prospective criterion standard study in patients after cardiac surgery. J Cardiothorac Vasc Anesth 14:125–129

    Article  CAS  PubMed  Google Scholar 

  17. Della Rocca G, Costa MG, Pompei L, Coccia C, Pietropaoli P (2002) Continous and intermittent cardiac output measurement: pulmonary artery catheter versus aortic transpulmonary technique. Br J Anaesth 88:350–356

    Article  PubMed  Google Scholar 

  18. Della Rocca G, Costa MG, Coccia C, et al (2003) Cardiac output monitorino: aortic transpulmonary thermodilution and pulse contour analysis agree with standard thermodilution methods in patients undergoing lung transplantation. Can J Anaesth 50:707–711

    Article  PubMed  Google Scholar 

  19. Rodig G, Prasser C, Keyl C, Liebold A, Hobbhahn (1999) Continuous cardiac output measurement: Pulse contour analysis versus thermodilution technique in cardiac surgical patients. Br J Anaesth 82:525–530

    CAS  PubMed  Google Scholar 

  20. Hamilton TT, Huber LM, Jessen ME (2002) PulseCO: a less-invasive method to monitor cardiac output from arterial pressure after cardiac surgery Ann Thorac Surg 74:S1408–S1412

    Google Scholar 

  21. Tsutsui M, Mori T, Aramaki Y, Fukuda I, Kazama T (2004) A comparison of two methods for continuous cardiac output measurement: PulseCO VS CCO. Masui 53:929–933

    PubMed  Google Scholar 

  22. Jonas MM, Tanser SJ (2002) Lithium dilution measurement of cardiac output and arterial pulse waveform analysis: an indicator dilution calibrated beat-by-beat system for continous estimation of cardiac output. Curr Opin Crit Care 8:257–261

    Article  PubMed  Google Scholar 

  23. Pittman J, Bar-Yosef S, Sumping J, Sherwood M, Mark J (2005) Continuous cardiac output monitoring with pulse contour analysis: A comparison with lithium indicator dilution cardiac output measurement. Crit Care Med 33:2015–2021

    Article  PubMed  Google Scholar 

  24. Romano SM, Pistolesi M (2002) Assessment of cardiac output from systemic arterial pressure in humans. Crit Care Med 30:1834–1841

    Article  PubMed  Google Scholar 

  25. Giomarelli P, Biagioli B, Scolletta S (2004) Cardiac output monitorino by pressare recording analytical method in cardiac surgery. Eur J Cardiothorac Surg 26:515–520

    Article  PubMed  Google Scholar 

  26. Scolletta S, Romano SM, Biagioli B, Capannini G, Giomarelli P (2005) Pressure recording analytical method (PRAM) for measurement of cardiac output during various haemodynamic states. Br J Anaest 95:159–165

    Article  CAS  Google Scholar 

  27. Langewouters GJ, Wesseling KH, Goedhard WJ (1984) The static elastic properties of 45 human thoracic and 20 abdominal aortas in vitro and the parameters of a new model. J Biomech 17:425–435

    Article  CAS  PubMed  Google Scholar 

  28. Manecke GR, Peterson M, Auger W (2004) Cardiac output determination using arterial pulse: a comparison of a novel algorithm against continuous and intermittent thermodilution. Crit Care Med 32:A43 (abst)

    Article  Google Scholar 

  29. McGee W, Horswell JL, Janvier G (2005) Validation of a continuous cardiac output measurement using arterial pressure waveforms. Crit Care 9:S24 (abst)

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2006 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Cecconi, M., Wilson, J., Rhodes, A. (2006). Pulse Pressure Analysis. In: Vincent, JL. (eds) Yearbook of Intensive Care and Emergency Medicine. Yearbook of Intensive Care and Emergency Medicine, vol 2006. Springer, Berlin, Heidelberg. https://doi.org/10.1007/3-540-33396-7_17

Download citation

  • DOI: https://doi.org/10.1007/3-540-33396-7_17

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-540-30155-4

  • Online ISBN: 978-3-540-33396-8

  • eBook Packages: MedicineMedicine (R0)

Publish with us

Policies and ethics