Summary
Although all commercially available bone cements are based on polymethylmethacrylate and other acrylic co-polymers, they all differ in their precise chemical formulation and composition. This results in different physical properties like viscosity, heat release, and mechanics. These differences affect surgical handling and clinical outcome. Various testing methods of bone cement are discussed in this chapter. Clinically most relevant is fatigue testing and traditional cements perform best.
Keywords
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
ASTM F2118-2001.Test method for constant amplitude of force controlled fatigue testing of acrylic bone cements materials. ASTM International, USA, 2001
Bellare A, Lee Y-L, Fitz W, Thornhill TS. Using nanotechnology to increase the fatigue life of acrylic bone cement. Transactions 51th Annual Meeting ORS, Washington, February 20–23 2005, p 288
Caywood GA, Gunasekaran S, Kharas GB. Synthesis and preclinical evaluation of a fast curing bioresorbable composite bone cement. Transactions of the Fifth World Biomaterials Congress, Toronto, Canada, May 29–June 2 1996, p 911
De Wijn JR. Porous polymethylmethacrylate cement. Dissertation University of Nijmegen, Nijmegen, The Netherlands, January 1982
Haboush EJ. A new operation for arthroplasty of the hip based on biomechanics, photoelasticity, fast-setting dental acrylic and other considerations. Scientific Exhibit, AAOS, Chicago, January 1952
ISO5833:2002. Implants for surgery-Acrylic resin cements. International Standardization Organisation, Switzerland, 2002
Jacobs CR. Bone cement compositions. World patent PCT/US99/05497, WO99/45978.The Penn State Research Foundation, 1999
Kruft MAB. New radio-opaque polymeric biomaterials. Dissertation University of Technology Eindhoven, Eindhoven, The Netherlands, April 1997
Mahanian S, Piziali RL. Finite element evaluation of the AIA shear specimen for bone. J Biomechanics 1988; 21: 346–356
Author information
Authors and Affiliations
Rights and permissions
Copyright information
© 2005 Springer Medizin Verlag Heidelberg
About this chapter
Cite this chapter
Spierings, P.T. (2005). Testing and Performance of Bone Cements. In: The Well-Cemented Total Hip Arthroplasty. Springer, Berlin, Heidelberg. https://doi.org/10.1007/3-540-28924-0_7
Download citation
DOI: https://doi.org/10.1007/3-540-28924-0_7
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-540-24197-3
Online ISBN: 978-3-540-28924-1
eBook Packages: MedicineMedicine (R0)