Skip to main content

Use of a Tensiometer at Total Knee Arthroplasty

  • Chapter
Total Knee Arthroplasty
  • 3209 Accesses

Summary

Soft-tissue alignment of the knee is important in total knee replacement. Achieving perfectly aligned and well-balanced soft tissues is more difficult than achieving good bony alignment. A mechanical balancer/tensiometer is an invaluable tool for this purpose and should be available to any surgeon performing knee arthroplasty.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 129.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Hanada H, Whiteside LA, Steiger J, Dyer P, Naito M (2004) Stability, alignment and contact stress in two techniques of TKA. Poster Presentation, 71st AAOS conference, March 2004

    Google Scholar 

  2. Wilton TJ, Sambatakakis A, Attfield F (1994) Soft-tissue balancing at the time of knee replacement: Rationale and method. Knee 1:111–116

    Article  Google Scholar 

  3. Attfield SF, Warren-Forward M, Wilton T, Sambatakakis AJ (1994) Measurement of soft tissue imbalance in total knee arthroplasty using electronic instrumentation. Med Eng Phys 16:501–505

    PubMed  Google Scholar 

  4. Griffin FM, Insall JN, Scudieri GR (2000) Accuracy of soft tissue balancing in total knee arthroplasty. J Arthroplasty 15:970

    Article  PubMed  Google Scholar 

  5. Attfield SF, Wilton TJ, Pratt DJ, Sambatakakis A (1996) Soft-tissue balance and recovery of proprioception after TKR. J Bone Joint Surg [Br] 78:540–545

    Google Scholar 

  6. Sambatakakis A, Wilton TJ, Newton G (1991) Radiographic sign of persistent soft tissue imbalance after knee replacement. J Bone Joint Surg [Br] 73 751–756

    Google Scholar 

  7. Ishii Y, Matsuda Y, Ishii R, et al (2003) Coronal laxity in extension in vivo after total knee arthroplasty. J Orthop Sci 8:683–692

    PubMed  Google Scholar 

  8. D’Lima D, Patil S, Steklov N, Slamin J, Collwell C Jr (2005) In vivo knee forces after total knee arthroplasty. Chitranjan Ranawat Award at Knee Society Open Meeting AAOS, February 26. Clin Orthop Rel Res (in press)

    Google Scholar 

  9. DeMarco AL, Rust DA, Bachus KN (2000) Measuring contact pressure and contact area in orthopaedic applications: Fuji Film vs Tekscan. Poster presentation, 46th ORS Annual Meeting, March 2000

    Google Scholar 

  10. Winemaker MJ (2002) Perfect balance in total knee arthroplasty — the elusive compromise. J Arthroplasty 17:2–10

    Article  Google Scholar 

Download references

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2005 Springer Medizin Verlag Heidelberg

About this chapter

Cite this chapter

Wilton, T.J. (2005). Use of a Tensiometer at Total Knee Arthroplasty. In: Bellemans, J., Ries, M.D., Victor, J.M. (eds) Total Knee Arthroplasty. Springer, Berlin, Heidelberg. https://doi.org/10.1007/3-540-27658-0_33

Download citation

  • DOI: https://doi.org/10.1007/3-540-27658-0_33

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-540-20242-4

  • Online ISBN: 978-3-540-27658-6

  • eBook Packages: MedicineMedicine (R0)

Publish with us

Policies and ethics