Skip to main content

Central Venous Pressure: Uses and Limitations

  • Conference paper
Book cover Functional Hemodynamic Monitoring

Part of the book series: Update in Intensive Care and Emergency Medicine ((UICMSOFT,volume 42))

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 219.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 279.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 379.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Boldt J, Lenz M, Kumle B, et al (1998) Volume replacement strategies on ICUs: results from a postal survey. Intensive Care Med 1998;24:147–151.

    Article  Google Scholar 

  2. Patterson SW, Piper H, Starling EH (1914) The regulation of the heart beat. J Physiol (Lond) 48:465–513

    Google Scholar 

  3. Patterson SW, Starling EH (1914) On the mechanical factors which determine the output of the ventricles. J Physiol (Lond) 48:357–379

    Google Scholar 

  4. Amoroso P, Greenwood RN (1989) Posture and central venous pressure measurement in circulatory volume depletion. Lancet 2:258–260

    Article  PubMed  Google Scholar 

  5. Frank O (1895) Zur Dynamik des Herzmuskels. Z Biol 32:370–437

    Google Scholar 

  6. Ishihara H, Suzuki A, Okawa H, et al (2000) The initial distribution volume of glucose rather than indocyanine green derived plasma volume is correlated with cardiac output following major surgery. Intensive Care Med 26:1441–1448

    Article  PubMed  Google Scholar 

  7. Michard F, Alaya S, Zarka V, et al (2003) Global end diastolic function as an indicator of cardiac preload in patients with septic shock. Chest 124:1900–1908

    Article  PubMed  Google Scholar 

  8. Sakka SG, Bredle DL, Reinhart K, et al (1999) Comparison between intrathoracic blood volume and cardiac filling pressures in the early phase of hemodynamic instability of patients with sepsis or septic shock. J Crit Care 14:78–83

    Article  PubMed  Google Scholar 

  9. Brock H, Gabriel C, Bibl D, et al (2002) Monitoring intravascular volumes for postoperative volume therapy. Eur J Anaesthesiol 19:288–294

    PubMed  Google Scholar 

  10. Gödje O, Peyerl M, Seebauer T, et al (1998) Central venous pressure, pulmonary capillary wedge pressure and intrathoracic blood volume as preload indicators in cardiac surgery patients. Eur J Cardiothorac Surg 13:533–540

    Article  PubMed  Google Scholar 

  11. Hinder F, Poelaert JI, Schmidt C, et al (1998) Assessment of cardiovascular volume status by transoesophageal echocardiography and dye dilution during cardiac surgery. Eur J Anaesthesiol 15:633–640

    PubMed  Google Scholar 

  12. Diebel LN, Wilson RF, Tagett MG, et al (1992) End-diastolic volume: a better indicator of preload in the critically ill. Arch Surg 127:817–822

    PubMed  Google Scholar 

  13. Buhre W, Weyland A, Schorn B, et al (1999) Changes in central venous pressure and pulmonary capillary wedge pressure do not indicate changes in right and left heart volume in patients undergoing coronary artery bypass surgery. Eur J Anaesthesiol 16:11–17

    Article  PubMed  Google Scholar 

  14. Samii K, Conseiller C, Viars P (1976) Central venous pressure and pulmonary wedge pressure: a comparative study in anaesthetised surgical patients. Arch Surg 111:1122–1125

    PubMed  Google Scholar 

  15. Bolte AC, Dekker GA, van Eyck J, et al (2000) Lack of agreement between central venous pressure and pulmonary capillary wedge pressure in preeclampsia. Hypertens Pregnancy 19:261–271

    Article  PubMed  Google Scholar 

  16. Magder S (1998) More respect for the CVP. Intensive Care Med 24:651–653

    Article  PubMed  Google Scholar 

  17. Michard F, Teboul JL (2002) Predicting fluid responsiveness in ICU Patients. Chest 121:2000–2008

    Article  PubMed  Google Scholar 

  18. Calvin JF, Driedger AA, Sibbald WJ (1981) The hemodynamic effect of rapid fluid infusion in critically ill patients. Surgery 90:61–76

    PubMed  Google Scholar 

  19. Reuse C, Vincent JL, Pinsky MR (1990) Measurements of right ventricular fluid volumes during fluid challenge. Chest 98:1450–1454

    PubMed  Google Scholar 

  20. Michard F, Boussat S, Chemla D, et al (2000) Relation between respiratory changes in arterial pulse pressure and fluid responsiveness in septic patients with acute circulatory failure. Am J Respir Crit Care Med 162:134–138

    PubMed  Google Scholar 

  21. Schneider AJ, Teule GJJ, Groenveld ABJ, et al (1998) Biventricular performance duringvolume loading in patients with early septic shock, with emphasis on the right ventricle: a combined hemodynamic and radionuclide study. Am Heart J 116:103–112

    Article  Google Scholar 

  22. Wagner JG, Leatherman JW (1998) Right ventricular end-diastolic volume as a predictor of the hemodynamic response to a fluid challenge. Chest 113:1048–1054

    PubMed  Google Scholar 

  23. Magder S, Georgiadis G, Cheong T (1992) Respiratory variations in right atrial pressure predict the response to fluid challenge. J Crit Care 7:76–85.

    Article  Google Scholar 

  24. Magder S, Lagondis D (1999) Effectiveness of albumin versus normal saline as a test of volume responsiveness in post cardiac surgery patients. J Crit Care 14:164–171

    Article  PubMed  Google Scholar 

  25. Magder S, De Varennes B (1998) Clinical death and the measurement of stressed vascular volume. Crit Care Med 26:1061–1064

    Article  PubMed  Google Scholar 

  26. Alrawi SJ, Miranda LS, Cunningham Jr JN, et al (2002) Correlation of blood volume values and pulmonary artery catheter measurements. Saudi Med J 23:1367–1372

    PubMed  Google Scholar 

  27. Shippy CR, Appel PL, Shoemaker WC (1984) Reliability of clinical monitoring to assess blood volume in critically ill patients. Crit Care Med 12:107–112

    PubMed  Google Scholar 

  28. Klaus S, Eichler W, Heringlake M, et al (2002) Assessment of fluid balance by measurement of skin tissue thickness during clinical anaesthesia. Clin Physiol Funct Imaging 22:197–201

    Article  PubMed  Google Scholar 

  29. Venn R, Steele A, Richardson P, et al (2002) Randomized controlled trial to investigate influence of the fluid challenge on duration of hospital stay and perioperative morbidity in patients with hip fractures. Br J Anaesth 88:65–71

    Article  PubMed  Google Scholar 

  30. Thomsen HS, Lokkegaard H, Munck O (1987) Influence of normal central venous pressure on onset of function in renal allografts. Scand J Urol Nephrol 21:143–145

    PubMed  Google Scholar 

  31. Rady MY, Ryan T, Starr NJ (1998) Perioperative determinants of morbidity and mortality in elderly patients undergoing cardiac surgery. Crit Care Med 26:225–235

    Article  PubMed  Google Scholar 

  32. Jellinek H, Krafft P, Fitzgerald R, et al (2000) Right atrial pressure predicts hemodynamic response to apneic positive airway pressure. Crit Care Med 28:672–678

    Article  PubMed  Google Scholar 

  33. Magder S, Lagondis D, Erice F (2001) The use of respiratory variations in right atrial pressure to predict the cardiac output response to PEEP. J Crit Care 16:108–114

    Article  PubMed  Google Scholar 

  34. Pearson KS, Gomez MN, Moyers JR, et al (1989) A cost/benefit analysis of randomized invasive monitoring for patients undergoing cardiac surgery. Anesth Analg 69:336–341

    PubMed  Google Scholar 

  35. Stewart RD, Psyhojos T, Lahey SJ, et al (1998) Central venous catheter use in low-risk coronary artery bypass grafting. Ann Thorac Surg 66:1306–1311

    Article  PubMed  Google Scholar 

  36. Shoemaker WC, Kram HB, Appel PL, et al (1990) The efficacy of central venous and pulmonary artery catheters and therapy based upon them in reducing mortality and morbidity. Arch Surg 125:1332–1337

    PubMed  Google Scholar 

  37. Rivers E, Nguyen B, Havstad S, et al (2001) Early goal-directed therapy in the treatment of severe sepsis and septic shock. N Engl J Med 345:1368–1377

    Article  PubMed  Google Scholar 

  38. Sznajder JI, Zveibil FR, Bitterman H, et al (1986) Failure and complication rates by three percutaneous approaches. Arch Intern Med 146:259–261

    Article  PubMed  Google Scholar 

Download references

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2005 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Smith, T., Grounds, R.M., Rhodes, A. (2005). Central Venous Pressure: Uses and Limitations. In: Pinsky, M.R., Payen, D. (eds) Functional Hemodynamic Monitoring. Update in Intensive Care and Emergency Medicine, vol 42. Springer, Berlin, Heidelberg. https://doi.org/10.1007/3-540-26900-2_8

Download citation

  • DOI: https://doi.org/10.1007/3-540-26900-2_8

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-540-22349-8

  • Online ISBN: 978-3-540-26900-7

  • eBook Packages: MedicineMedicine (R0)

Publish with us

Policies and ethics