Abstract

Stereotactic ablative radiotherapy (SABR) is a new paradigm in radiation therapy, achieving high rates of local tumor control with low toxicity through very high dose intensity and conformity, and requiring highly precise and accurate delivery. The CyberKnife robotic radiosurgery system, originally designed for frameless intracranial radiosurgery using automated image-guidance, has unique characteristics suitable for lung tumor SABR, including dynamic tumor tracking capabilities. We review here the technical characteristics and clinical outcomes of lung tumor SABR using the CyberKnife system.

This is a preview of subscription content, log in via an institution.

Buying options

Chapter
USD   29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD   219.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD   279.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Learn about institutional subscriptions

References

  • Ahn SH, Han MS, Yoon JH et al (2009) Treatment of stage I non-small cell lung cancer with CyberKnife, image-guided robotic stereotactic radiosurgery. Oncol Rep 21:693–696

    PubMed  Google Scholar 

  • Anantham D, Feller-Kopman D, Shanmugham LN et al (2007) Electromagnetic navigation bronchoscopy-guided fiducial placement for robotic stereotactic radiosurgery of lung tumors: a feasibility study. Chest 132:930–935

    Article  PubMed  Google Scholar 

  • Baumann P, Nyman J, Hoyer M et al (2009) Outcome in a prospective Phase II trial of medically inoperable Stage I non-small cell lung cancer patients treated with stereotactic body radiotherapy. J Clin Oncol 27:3290–3296

    Article  PubMed  Google Scholar 

  • Brown JM, Diehn M, Loo BW (2010) Stereotactic ablative radiotherapy should be combined with a hypoxic cell radiosensitizer. Int J Radiat Oncol Biol Phys 78:323–327

    Article  PubMed  Google Scholar 

  • Brown WT, Wu X, Amendola B et al (2007a) Treatment of early non-small cell lung cancer, stage IA, by image-guided robotic stereotactic radioablation–CyberKnife. Cancer J 13:87–94

    Article  PubMed  Google Scholar 

  • Brown WT, Wu X, Fayad F et al (2007b) CyberKnife radiosurgery for stage I lung cancer: results at 36 months. Clin Lung Cancer 8:488–492

    Article  PubMed  Google Scholar 

  • Brown WT, Wu X, Wen BC et al (2007c) Early results of CyberKnife image-guided robotic stereotactic radiosurgery for treatment of lung tumors. Comput Aided Surg 12:253–261

    PubMed  Google Scholar 

  • Brown WT, Wu X, Fayad F et al (2009) Application of robotic stereotactic radiotherapy to peripheral stage I non-small cell lung cancer with curative intent. Clin Oncol (R Coll Radiol) 21:623–631

    Article  CAS  Google Scholar 

  • Brown WT, Wu X, Fowler JF et al (2008) Lung metastases treated by CyberKnife image-guided robotic stereotactic radiosurgery at 41 months. South Med J 101:376–382

    Article  PubMed  Google Scholar 

  • Chang CN, Zhou LY, MacFarlane G et al (2009) Excellent early local control with tumor volume adapted dosing of stereotactic body radiation therapy for pulmonary tumors. J Thorac Oncol 4:S938–S939

    Google Scholar 

  • ClinicalTrials.gov (2008) CyberKnife radiosurgical treatment of inoperable early stage non-small cell cancer. http://www.clinicaltrials.gov/show/NCT00643318. Accessed 1 Mar 2011

  • ClinicalTrials.gov (2009) International randomized study to compare CyberKnife stereotactic radiotherapy with surgical resection in stage I non-small cell lung cancer (STARS). http://www.clinicaltrials.gov/show/NCT00840749. Accessed 1 Mar 2011

  • Collins BT, Erickson K, Reichner CA et al (2007) Radical stereotactic radiosurgery with real-time tumor motion tracking in the treatment of small peripheral lung tumors. Radiat Oncol 2:39

    Article  PubMed  Google Scholar 

  • Collins BT, Vahdat S, Erickson K et al (2009) Radical cyberknife radiosurgery with tumor tracking: an effective treatment for inoperable small peripheral stage I non-small cell lung cancer. J Hematol Oncol 2:1

    Article  PubMed  Google Scholar 

  • Coon D, Gokhale AS, Burton SA, Heron DE, Ozhasoglu C, Christie N (2008) Fractionated stereotactic body radiation therapy in the treatment of primary, recurrent, and metastatic lung tumors: the role of positron emission tomography/computed tomography-based treatment planning. Clin Lung Cancer 9:217–221

    Article  PubMed  Google Scholar 

  • CyberKnife radiosurgical treatment of inoperable early stage non-small cell cancer. Accessed March 1, 2011. http://www.clinicaltrials.gov/show/NCT00643318

  • Ding C, Chang C-H, Haslam J, Timmerman R, Solberg T (2010) A dosimetric comparison of stereotactic body radiation therapy techniques for lung cancer: robotic versus conventional linac-based systems. J Appl Clin Med Phys/Am Coll Med Phys 11:3223

    Google Scholar 

  • Harley DP, Krimsky WS, Sarkar S, Highfield D, Aygun C, Gurses B (2010) Fiducial marker placement using endobronchial ultrasound and navigational bronchoscopy for stereotactic radiosurgery: an alternative strategy. Ann Thorac Surg 89:368–373 Discussion 73-4

    Article  PubMed  Google Scholar 

  • Hong JC, Yu Y, Rao AK et al (2010) High retention and safety of percutaneously implanted endovascular embolization coils as fiducial markers for image-guided stereotactic ablative radiotherapy of pulmonary tumors. Int J Radiat Oncol Biol Phys, in press, published online ahead of print August 2010

    Google Scholar 

  • Hoogeman M, Prévost J-B, Nuyttens J, Pöll J, Levendag P, Heijmen B (2009) Clinical accuracy of the respiratory tumor tracking system of the cyberknife: assessment by analysis of log files. Int J Radiat Oncol Biol Phys 74:297–303

    Article  PubMed  Google Scholar 

  • International randomized study to compare CyberKnife stereotactic radiotherapy with surgical resection in Stage I non-small cell lung cancer (STARS). (Accessed March 1, 2011, at http://www.clinicaltrials.gov/show/NCT00840749.)

  • Kothary N, Heit JJ, Louie JD et al (2009) Safety and efficacy of percutaneous fiducial marker implantation for image-guided radiation therapy. J Vasc Interv Radiol: JVIR 20:235–239

    Article  PubMed  Google Scholar 

  • Le Q-T, Loo BW, Ho A et al (2006) Results of a phase I dose-escalation study using single-fraction stereotactic radiotherapy for lung tumors. J Thorac Oncol 1:802–809

    Article  PubMed  Google Scholar 

  • Muacevic A, Drexler C, Wowra B et al (2007) Technical description, phantom accuracy, and clinical feasibility for single-session lung radiosurgery using robotic image-guided real-time respiratory tumor tracking. Technol Cancer Res Treat 6:321–328

    PubMed  CAS  Google Scholar 

  • Nuyttens JJ, Prévost J-B, Praag J et al (2006) Lung tumor tracking during stereotactic radiotherapy treatment with the CyberKnife: Marker placement and early results. Acta Oncol 45:961–965

    Article  PubMed  CAS  Google Scholar 

  • Pennathur A, Luketich JD, Burton S et al (2007) Stereotactic radiosurgery for the treatment of lung neoplasm: initial experience. Ann Thorac Surg 83:1820–1824 discussion 4-5

    Article  PubMed  Google Scholar 

  • Pennathur A, Luketich JD, Heron DE et al (2009a) Stereotactic radiosurgery for the treatment of lung neoplasm: experience in 100 consecutive patients. Ann Thorac Surg 88:1594–1600 discussion 600

    Article  PubMed  Google Scholar 

  • Pennathur A, Luketich JD, Heron DE et al (2009b) Stereotactic radiosurgery for the treatment of stage I non-small cell lung cancer in high-risk patients. J Thorac Cardiovasc Surg 137:597–604

    Article  PubMed  Google Scholar 

  • Prévost J-BG, Nuyttens JJ, Hoogeman MS, Pöll JJ, van Dijk LC, Pattynama PMT (2008) Endovascular coils as lung tumour markers in real-time tumour tracking stereotactic radiotherapy: preliminary results. Eur Radiol 18:1569–1576

    Article  PubMed  Google Scholar 

  • Schroeder C, Hejal R, Linden PA (2010) Coil spring fiducial markers placed safely using navigation bronchoscopy in inoperable patients allows accurate delivery of CyberKnife stereotactic radiosurgery. J Thorac Cardiovasc Surg 140:1137–1142

    Article  PubMed  Google Scholar 

  • Schweikard A, Glosser G, Bodduluri M, Murphy MJ, Adler JR (2000) Robotic motion compensation for respiratory movement during radiosurgery. Comput Aided Surg 5:263–277

    Article  PubMed  CAS  Google Scholar 

  • Schweikard A, Shiomi H, Adler J (2004) Respiration tracking in radiosurgery. Med Phys 31:2738–2741

    Article  PubMed  Google Scholar 

  • Sharma SC, Ott JT, Williams JB, Dickow D (2010) Clinical implications of adopting Monte Carlo treatment planning for CyberKnife. J Appl Clin Med Phys/Amer Coll Med Phys 11:3142

    Google Scholar 

  • Timmerman R, Paulus R, Galvin J et al (2010) Stereotactic body radiation therapy for inoperable early stage lung cancer. JAMA 303:1070–1076

    Article  PubMed  CAS  Google Scholar 

  • Trakul N, Harris J, Dieterich S et al (2010) Volume adapted dosing in stereotactic ablative radiotherapy of lung tumors. Int J Radiat Oncol Biol Phys 78(3 suppl 1):S179

    Article  Google Scholar 

  • Unger K, Ju A, Oermann E, et al. (2010) CyberKnife for hilar lung tumors: report of clinical response and toxicity. J Hematol Oncol 3:39–45

    Article  PubMed  Google Scholar 

  • Vahdat S, Oermann EK, Collins SP et al (2010) CyberKnife radiosurgery for inoperable stage IA non-small cell lung cancer: 18F-fluorodeoxyglucose positron emission tomography/computed tomography serial tumor response assessment. J Hematol Oncol 3:6

    Article  PubMed  Google Scholar 

  • van der Voort van Zyp NC, Prévost J-B, Hoogeman MS et al (2009) Stereotactic radiotherapy with real-time tumor tracking for non-small cell lung cancer: clinical outcome. Radiother and Oncol J Eur Soc Ther Radiol and Oncol 91:296–300

    Article  Google Scholar 

  • van der Voort van Zyp NC, Hoogeman MS, van de Water S et al (2010a) Clinical introduction of Monte Carlo treatment planning: a different prescription dose for non-small cell lung cancer according to tumor location and size. Radiother and Oncol J Eur Soc Ther Radiol Oncol 96:55–60

    Article  Google Scholar 

  • van der Voort van Zyp NC, Prévost J-B, van der Holt B et al (2010b) Quality of life after stereotactic radiotherapy for stage I non-small cell lung cancer. Int J Radiat Oncol Biol Phys 77:31–37

    Article  Google Scholar 

  • van der Voort van Zyp NC, van der Holt B, van Klaveren RJ, Pattynama P, Maat A, Nuyttens JJ (2010c) Stereotactic body radiotherapy using real-time tumor tracking in octogenarians with non-small cell lung cancer. Lung Cancer 69:296–301

    Article  Google Scholar 

  • Whyte RI, Crownover R, Murphy MJ et al (2003) Stereotactic radiosurgery for lung tumors: preliminary report of a phase I trial. Ann Thorac Surg 75:1097–1101

    Article  PubMed  Google Scholar 

  • Wilcox EE, Daskalov GM, Lincoln H, Shumway RC, Kaplan BM, Colasanto JM (2010) Comparison of planned dose distributions calculated by Monte Carlo and Ray-Trace algorithms for the treatment of lung tumors with cyberknife: a preliminary study in 33 patients. Int J Radiat Oncol Biol Phys 77:277–284

    Article  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Billy W. Loo Jr. .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2011 Springer-Verlag Berlin Heidelberg

About this chapter

Cite this chapter

Loo, B.W., Gibbs, I.C. (2011). Image-Guided Robotic Stereotactic Ablative Radiotherapy for Lung Tumors: The CyberKnife. In: Jeremic, B. (eds) Advances in Radiation Oncology in Lung Cancer. Medical Radiology(). Springer, Berlin, Heidelberg. https://doi.org/10.1007/174_2011_276

Download citation

  • DOI: https://doi.org/10.1007/174_2011_276

  • Published:

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-642-19924-0

  • Online ISBN: 978-3-642-19925-7

  • eBook Packages: MedicineMedicine (R0)

Publish with us

Policies and ethics