  • Chapter
  • 4083 Accesses

The widespread use of NMR in materials testing is hampered by the fact that the object needs to be carried to the NMR equipment and needs to fit inside the magnet [1]. Both limitations are removed by mobile unilateral NMR at the expense of a lower and inhomogeneous magnetic polarization field [2]. Originally, open sensors were developed by the well-logging industries [3]. There, transverse relaxation decays are measured from the fluids in the porous formation with a spectrometer positioned inside the borehole. For well-logging sensors, the field gradient is minimized in a sweet spot or adjusted to a small value so as to eliminate signal attenuation from translational diffusion for short echo times [4–6]. Parallel to the development of the first well-logging tools, the first unilateral sensors were developed mostly for measuring moisture in soil, bridge decks, building materials, and food [7–12]. Some of these instruments employed electromagnets weighing several hundred kilograms. As long as solid materials including rubber are investigated even large field gradients can be tolerated as diffusion is absent. This is the idea behind the NMR-MOUSE, which operates with permanent magnets at frequencies between 10 and 20 MHz with magnetic field gradients up to 20 T/m (Figure 1)[13–16]. The NMR-MOUSE weights less than 1 kg, but is limited to depths typically less than 15 mm.

This is a preview of subscription content, log in via an institution.

Buying options

Chapter
USD   29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD   869.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD   1,099.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Learn about institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2008 Springer

About this chapter

Cite this chapter

Blümich, B., Casanova, F. (2008). Mobile NMR. In: Webb, G.A. (eds) Modern Magnetic Resonance. Springer, Dordrecht. https://doi.org/10.1007/1-4020-3910-7_45

Download citation

Publish with us

Policies and ethics