Advertisement

Inflammatory Response to Metals and Ceramics

  • Arturo Pizzoferrato
  • Elisabetta Cenni
  • Gabriela Ciapetti
  • Donatella Granchi
  • Lucia Savarino
  • Susanna Stea
Chapter

Keywords

Mast Cell Corrosion Product Aseptic Loosening Wear Debris Wear Particle 
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Agins, H.J., Alcock, N.W., Bansal, M., Salvati, E.A., Wilson, P.D., Pellicci, P.M., Bullough, P. G. 1988. Metallic wear in failed titanium alloy total hip replacements. A histological and quantitative analysis, J. Bone Jt. Surg. 70, 347–356.Google Scholar
  2. al-Saffar, N., Mah, J.T., Kadoya, Y., Revell, P.A. 1995a. Neovascularisation and the induction of cell adhesion molecules in response to degradation products from orthopaedic implants, Ann. Rheum. Dis. 54, 201–208.CrossRefGoogle Scholar
  3. al-Saffar, N., Revell, P.A., Khwaja, H.A. Bonfield, W. 1995b. Assessment of the role of cytokines in bone resorption in patients with total joint replacement, J. Mat. Sci. Mater. Med. 6, 762–767.Google Scholar
  4. Alenius, H., Palosuo, T., Kelly, K., Kurup, V., Reunala, T., Makinen-Kiljunen, S., Turjanmaa, K., Fink, J. 1993. IgE reactivity to 14 KD and 27 KD natural rubber proteins in latex allergic children with spina bifida and other congenital anomalies, Int. Arch. Allerg. Immunol. 102, 61–66.Google Scholar
  5. Alliot-Licht, B., Jean, A., Gregoire, M. 1994. Comparative effect of calcium hydroxide and hydroxyapatite on the cellular activity of human pulp fibroblasts in vitro, Arch. Oral Biol. 39, 481–489.Google Scholar
  6. Amstutz, H.C., Grigoris, P. 1996. Metal on metal bearings in hip arthroplasty, Clin. Orthop. s329, S11–34.Google Scholar
  7. Arnaout, M.A. 1990. Structure and function of the leukocyte adhesion molecules CD11/CD18, Blood 75, 1037–1050.Google Scholar
  8. Beard, R.B., Carim, H., De Rosa, J.F., Dubin, S., Koerner, R., Miller, A.S. 1976. Biocompatibility of electrodes for implantable power sources, in: Biocompatibility of Implant Materials (D.F. Williams, ed.), Chap. 16, Sector Publishing, London.Google Scholar
  9. Biselli, R., Matricardi, P.M., D’Amelip, R., Fattorossi, A. 1992. Multiparametric flow cytometric R., analysis of the kinetics of surface molecule expression after polyclonal activation of human peripheral blood T lymphocytes, Scand. J. Immunol. 35, 439–447.Google Scholar
  10. Bjurholm, A., al-Tawil, N.A., Marcusson, J.A., Netz, P. 1990. The lymphocyte response to nickel salt in patients with orthopedic implants, Acta Orthop. Scand. 61, 248–250.Google Scholar
  11. Blaheta, R.A., Franz, M., Auth, M.K.H., Wenish, H.J.C., Markus, B.H. 1991. A rapid nonradioactive fluorescence assay for the measurement of both cell number and proliferation, J. Immunol. Meth., 142, 199–206.CrossRefGoogle Scholar
  12. Blaine, T.A., Pollice, P.F., Rosier, R.N., Reynolds, P.R., Puzas, J.E., O’Keefe, R.J. 1997. Modulation of the production of cytokines in titanium-stimulated human peripheral blood monocytes by pharmacological agents. The role of cAMP-mediated signaling mechanisms, J. Bone Jt. Surg., Am. Vol. 79, 1519–1528.Google Scholar
  13. Bloebaum, R.D., Lundeen, G.A., Bachus, K.N., Ison, I., Hofmann, A.A. 1998. Dissolution of partiulate hydroxyapatite in a macrophage organelle model, J. Biomed Mater. Res. 40, 104–114.CrossRefGoogle Scholar
  14. Bohne, W., Pouezat, J.A., Peru, L., Daculsi, G. 1993. Heating of calcium phosphate crystals: morphological consequences and biological implications, Cells Mater. 3, 377–382.Google Scholar
  15. Bosetti, M., Ottani, V., Kozel, D., Raspanti, M., De Pasquale, V., Ruggeri, A., Cannas, M. 1999. Structural and functional macrophages alterations by ceramics of different composition, Biomaterials 20, 363–370.CrossRefGoogle Scholar
  16. Boyden, S. 1962. The chemotactic effect of mixtures antibody and antigen on polymorphonuclear leucocytes, J. Exp. Med. 115, 453–458.CrossRefGoogle Scholar
  17. Campoccia, D., Hunt, J.A., Doherty, P.J., Zhong, S.P., Callegaro, L., Benedetti, L., Williams, D.F. 1993. Human neutrophil chemokinesis and polarization induced by hyaluronic acid derivatives, Biomaterials 14, 1135–1139.CrossRefGoogle Scholar
  18. Cancilleri, F., De Giorgis, P., Verdoia, C., Parrini, L., Lodi, A., Crosti, C. 1992. Allergy to components of total hip arthroplasty before and after surgery, Ital. J. Orthop. Traumatol. 18, 407–410.Google Scholar
  19. Carlsson, A., Moller, H. 1989. Implantation of orthopaedic devices in patients with metal allergy, Acta Derm. Venereol. 69, 62–66.Google Scholar
  20. Carlsson, A., Magnusson, B., Moller, H. 1980. Metal sensitivity in patients with metal-to-plastic total hip arthroplasties, Acta Orthop. Scand. 51, 57–62.Google Scholar
  21. Carracedo, J., Ramirez, R., Martin Malo, A., Rodriguez, M., Aljama, P. 1998. Nonbiocompatible hemodialysis membranes induce apoptosis in mononuclear cells: the role of G-protein, J. Am. Soc. Nephrol. 9, 46–53.Google Scholar
  22. Case, C.P., Langlamer, V.G., James, C., Palmer, M.R., Kemp, A.J., Heap, P.F., Solomon, L. 1994. Widespread dissemination of metal debris from implant, J. Bone Jt. Surg. Br. Vol. 76, 701–712.Google Scholar
  23. Cheung, H.S., Haak, M.H. 1989. Growth of osteoblasts on porous calcium phosphate ceramics: an in vitro model for biocompatibility study, Biomaterials 10, 63–67.CrossRefGoogle Scholar
  24. Chiba, J., Rubash, H.E., Kim, K.J., Iwaki, Y. 1994. The characterization of cytokines in the interface tissue obtained from failed cementless total hip arthroplasty with and without femoral osteolysis, Clin. Orthop. 300, 304–312.Google Scholar
  25. Ciapetti, G., Roda, P., Landi, L., Facchini, A., Pizzoferrato, A. 1992. In vitro methods to evaluate metal-cell interactions, Int. J. Artif. Organs 15, 62–66.Google Scholar
  26. Ciapetti, G., Cenni, E., Pratelli, L., Pizzoferrato, A. 1993. In vitro evaluation of cell/biomaterial interaction by MTT assay, Biomaterials 14(5), 359–364.CrossRefGoogle Scholar
  27. Ciapetti, G., Granchi, D., Verri, E., Savarino, L., Savioli, F., Dallari, D., Gualtieri, G., Pizzoferrato, A. 1997. Effect of metal ions on leucocytes from patients with metal implants, 13th European Conference on Biomaterials, Goteborg (Sweden), 4–7 September 1997, Abstract P127.Google Scholar
  28. Ciapetti, G., Granchi, D., Verri, E., Savarino, L., Cenni, E., Savioli, F., Pizzoferrato, A. 1998. Fluorescent microplate assay for respiratory burst of PMNs challenged in vitro with orthopedic metals, J. Biomed. Mater. Res. 41, 455–460.CrossRefGoogle Scholar
  29. Daculsi, G., Passuti, N. 1990a. Effect of the macroporosity for osseous substitution of calcium phosphate ceramics, Biomaterials 11, 86–87.Google Scholar
  30. Daculsi, G., LeGeros, R.Z., Heughebaert, J.C., Barbieux, I. 1990. Formation of carbonate-apatite crystals after implantation of calcium phosphate ceramics, Calcif. Tissue Int. 46, 20–27.Google Scholar
  31. Daniels, A.U., Barnes, F.H., Charlebois, S.J., Smith, R.A. 2000. Macrophage cytokine response to particles and lypopolysaccharide in vitro, J. Biomed. Mater. Res. 49, 469–478.CrossRefGoogle Scholar
  32. Darzynkievicz, Z., Bruno, S., Del Bino, G., Gorczyca, W., Hotz, M.A., Lassota, P., Traganos, F. 1992. Features of apoptotic cells measured by flow cytometry, Cytometry 13, 795–808.Google Scholar
  33. de Groot, K. 1983. Ceramics of calcium phosphates, preparation and properties, in: Bioceramics of Calcium-Phosphate (de Groot K, ed.), pp. 99–114, CRC Press, Boca Raton.Google Scholar
  34. de Groot, K., Wolke, J.G.C., Jansen, J.A. 1998. Calcium phosphate coatings for medical implants, J. Eng. Med. 212, 137–148.CrossRefGoogle Scholar
  35. Deutman, R., Mulder, T.J., Brian, R., Nater J.P. 1977. Metal sensitivity before and after total hip arthroplasty, J. Bone Jt. Surg. Am. Vol. 59, 862–865.Google Scholar
  36. Dobbs, H.S., Minski, M.J. 1980. Metal ion release after total hip replacement, Biomaterials 1, 193–198.CrossRefGoogle Scholar
  37. Dowsett, S.A., Hyvonen, P.M., Kowolik, M.J. 1997. Functional integrity of human neutrophils following 24 hour incubation with hydroxyapatite and fluoride, J. Biolumin. Chemilumin. 12, 215–221.CrossRefGoogle Scholar
  38. Ducheyne, P., Lemons, J.E. (eds.), 1988. Bioceramics: Materials Characteristics versus In Vivo Behavior, NY Academic Science, New York.Google Scholar
  39. Ducheyne, P., Qiu, Q. 1999. Bioactive ceramics: the effect of surface reactivity on bone formation and bone cell function, Biomaterials 20, 2287–2303.CrossRefGoogle Scholar
  40. Dupraz, A., Delecrin, J., Moreau, A., Pilet, P., Passuti, N. 1998. Long-term bone response to particulate injectable ceramic, J. Biomed. Mater. Res. 42, 368–375.CrossRefGoogle Scholar
  41. Elwing, H., Tengvall, P., Askendal, A., Lundstrom, I. 1991. “Lens-on-surface”: a versatile method for the investigation of plasma protein exchange reactions on solid surfaces, J. Biomater. Sci. Polym. Ed. 3, 7–15.Google Scholar
  42. Endler, M., Endler, T.A., Zielinski, C. 1982. Influence of hip arthroplasty upon chemotactic behaviour of leucocytes, Acta Orthop. Scand. 53, 795–799.Google Scholar
  43. Freyria, A.M., Chignier, E., Guidollet, J., Luisot, P. 1991. Peritoneal macrophage response: an in vivo model for the study of synthetic materials, Biomaterials 12, 111–118.CrossRefGoogle Scholar
  44. Fukuchi, N., Akao, M., Sato, A. 1995. Effect of hydroxyapatite microcrystals on macrophage activity, Biomed. Mater. Eng. 5, 219–231.Google Scholar
  45. Gangarosa, E.J., Inglefield, J.T., Thomas, C.G.A., Morgan, H.R. 1955. Studies on hypersensitivity of human tissues in vitro, J. Exp. Med. 101, 425–433.Google Scholar
  46. Giudiceandrea, F., lacona, A., Cervelli, G., Grimaldi, M., Maggiulli, G., Cococcetta, N., Cervelli, V. 1998. Mechanisms of bone resorption: analysis of proinflammatory cytokines in peritoneal macrophages from titanium implant — an experimental design, J. Craniofac. Surg. 9, 254–259.Google Scholar
  47. Glant T.T., Jacobs, J.J., Molnar, G., Shanbhag, A.S., Valyon, M., Galante, J.O. 1993. Bone resorption activity of particulate-stimulated macrophages, J. Bone Miner. Res. 8, 1071–1079.CrossRefGoogle Scholar
  48. Goebeler, M., Meinardus-Hager, G., Roth, J., Goerdt, S. and Sorg, C., 1993, Nickel chloride and cobalt chloride, two common contact sensitizers, directly induce expression of intercellular adhesion molecule-1 (ICAM-1), vascular cell adhesion molecule-1 (VCAM-1), and endothelial leukocyte adhesion molecule (ELAM-1) by endothelial cells, J. Invest. Dermatol. 100, 759–765.CrossRefGoogle Scholar
  49. Goebeler, M., Roth, J., Brocker, E.B., Sorg, C., Schulze-Osthoff, K. 1995. Activation of nuclear factor-kappa B and gene expression in human endothelial cells by the common haptens nickel and cobalt, J. Immunol. 155, 2459–2467.Google Scholar
  50. Goldring, S.R., Jasty, M., Roelke, M.S., Rourke, C.M., Bringhurst, F.R., Harris, W.H. 1986 Formation of a synovial-like membrane at the bone-cement interface: its role in bone resorption and implant loosening after total hip replacement, Arthritis Rheumatol. 29, 836–842.Google Scholar
  51. Gonzales, J.B., Purdon, M.A., Horowitz, S.M. 1996. In vitro studies on the role of titanium in aseptic loosening, Clin. Orthop. 330, 244–250.Google Scholar
  52. Goodman, S.B., Fornasier, V.L., Lee, J., Kei, J. 1990. The effects of bulk versus particulate titanium and cobalt chrome alloy implanted into the rabbit tibia, J. Biomed. Mater. Res. 24, 1539–1549.Google Scholar
  53. Goodman, S.B., Aspenberg, P., Spang, Y., Doshi, A., Regula, D., Lidgren L. 1995. Effects of particulate high-density polyethylene and titanium alloy on tissue ingrowth into bone harvest chamber in rabbits, J. Appl. Biomater. 6, 27–33.Google Scholar
  54. Goodman, S.B., Davidson, J.A., Song, Y., Martial, N., Fornasier, V.L. 1996a. Histomorphological reaction of bone to different concentrations of phagocytosable particles of high-density polyethylene and Ti-6A1-4V alloy in vivo, Biomaterials, 17, 1943–1947.Google Scholar
  55. Goodman, S.B., Knoblich, G., O’connor, M., Song, Y., Huie, P., Sibley, R. 1996b. Heterogeneity in cellular and cytokine profiles from multiple samples of tissue surrounding revised hip prostheses, J. Biomed. Mater. Res. 31, 421–428.CrossRefGoogle Scholar
  56. Granchi, D., Ciapetti, G., Stea, S., Cavedagna, D., Bettini, N., Bianco, T., Fontanesi, G., Pizzoferrato, A. 1995. Evaluation of several immunological parameters in patients with aseptic loosening of hip arthroplasty, Chir. Organi Mov. 80, 399–408.Google Scholar
  57. Granchi, D., Verri, E., Ciapetti, G., Savarino, L., Cenni, E., Gori, A., Pizzoferrato, A. 1998a. Effects of chromium extract on cytokine release by mononuclear cells, Biomaterials 19, 283–291.Google Scholar
  58. Granchi, D., Verri, E., Ciapetti, G., Stea, S., Savarino, L., Sudanese, A., Mieti, M., Rotini, R., Dallari, D., Zinghi, G., Montanaro, L. 1998b. Bone resorbing cytokines in serum of patients with aseptic loosening of hip prosthesis, J. Bone Jt. Surg. 80, 912–917.Google Scholar
  59. Granchi, D., Cenni, E., Ciapetti, G., Savarino, L., Stea, S., Gamberini, S., Gori, A., Pizzoferrato, A. 1998c. Cell death induced by metal ions, necrosis or apoptosis? J. Mater. Sci., Mater. Med. 9, 31–37.CrossRefGoogle Scholar
  60. Granchi, D., Ciapetti, G., Stea, S., Savarino, L, Filippini, F., Sudanese, A., Zinghi, G., Montanaro L. 1999. Cytokine release in mononuclear cells of patients with Co-Cr hip prosthesis, Biomaterials 20, 1079–1086.CrossRefGoogle Scholar
  61. Greppi, A.L., Smith, D.C., Woodside, D.G. 1989. Nickel hypersensitivity reactions in orthodontic patients. A literature review, Univ. Tor. Dent. J. 3, 11–14.Google Scholar
  62. Gruber, H.E. 1991. Bone and the immune system, Proc. Soc. Exp. Biol. Med. 197, 219–225.Google Scholar
  63. Harada, Y., Wang, J.T., Doppalapudi, V.A., Willis, A.A., Jasty, M., Harris, W.H., Nagase, M., Goldring, S.R. 1996. Differential effects of different forms of hydroxyapatite and hydroxyapatite/tricalcium phosphate particulates on human monocyte/macrophages in vitro, J. Biomed. Mater. Res. 31, 19–26.CrossRefGoogle Scholar
  64. Harms, J., Mausle, E. 1979. Tissue reaction to ceramic implant material, J. Biomed. Mater. Res. 13(1), 67–87.CrossRefGoogle Scholar
  65. Haynes, D.R., Rogers, S.D., Hay, S., Pearcy, M.J., Howie, D.W. 1993. The difference in toxicity and release of bone-resorbing mediators induced by titanium and cobalt-chromium-alloy wear particles, J. Bone Jt. Surg., Am. Vol. 75, 825–834.Google Scholar
  66. Haynes, D.R., Rogers, S.D., Howie, D.W., Pearcy, M.J., Vernon-Roberts, B. 1996. Drug inhibition of the macrophage response to metal wear particles in vitro, Clin. Orthop. 323, 316–326.Google Scholar
  67. Haynes D.R., Hay, S.J., Rogers, S.D., Ohta, S., Howie, D.W., Graves, S.E. 1997. Regulation of bone cells by particle-activated mononuclear phagocytes, J. Bone Jt. Surg., Br. Vol. 79, 988–994.Google Scholar
  68. Haynes, D.R., Boyle, S.J., Rogers, S.D., Howie, D.W., Vernon-Roberts, B. 1998. Variation in cytokines induced by particles from different prosthetic materials, Clin. Orthop. 352, 223–230.Google Scholar
  69. Haynes, D.R., Crotti, T.N., Haywood, M.R. 2000. Corrosion of and changes in biological effects of cobalt chrome alloy and 316L stainless steel prosthetic particles with age, J. Biomed. Mater. Res. 49, 167–175.CrossRefGoogle Scholar
  70. Heese, A., Peters, K.P., Koch, H. 1997. Type I allergies to latex and the aeroallergenic problem, Eur. J. Surg. Suppl. 579, 19–22.Google Scholar
  71. Hickmann, J.A., Boyle, C.C. 1996. Apoptosis and cytotoxins, Br. Med. Bull., 52, 632–643.Google Scholar
  72. Hirakawa, K., Bauer, T.W., Stulberg, B.N., Wilde, A.H. 1996. Comparison and quantitation of wear debris of failed total hip and knee arthroplasty, J. Biomed. Mater. Res. 31, 257–263.CrossRefGoogle Scholar
  73. Horowitz, S.M., Luchetti, W.T., Gonzales, J.B., Ritchie, C.K. 1998. The effects of cobalt chromium upon macrophages, J. Biomed. Mater. Res. 41, 468–473.CrossRefGoogle Scholar
  74. Hujanen E.S., Seppa S.T., Virtanen K. 1995. Polymorphonuclear leukocyte chemotaxis induced by zinc, copper and nickel in vitro, Biochim. Biophys. Acta 1245, 145–152.Google Scholar
  75. Hukkanen, M., Corbett, S.A., Batten, J., Konttinen, Y.T., McCarthy, I.D., Maclouf, J., Santavirta, S., Hughes, S.P., Polak, J.M. 1997. Aseptic loosening of total hip replacement. Macrophage expression of inducible nitric oxide synthase and cyclo-oxygenase-2, together with peroxynitrite formation, as a possible mechanism for early prosthesis failure, J. Bone Jt. Surg., Br. Vol. 79, 467–474.Google Scholar
  76. Hunt, J.A., Remes, A., Williams, D.F. 1992. Stimulation of neutrophil movement by metal ions, J. Biomed. Mater. Res. 26, 819–828.CrossRefGoogle Scholar
  77. Ibbotson, K.J., Twardzic, D.R., D’Souza, S.M., Hargreaves, W.A., Todaro, G.K., Mundy, G.R. 1985. Stimulation of bone resorption in vitro by systemic transforming growth factoralpha, Science 228, 1007–1011.Google Scholar
  78. Ishiguro, N., Kojima, T., Ito, T., Saga, S., Anma, H., Kurokouchi, K., Iwahori, Y., Iwase, T., Iwata, H. 1997. Macrophage activation and migration in interface tissue around loosening total hip arthroplasty components, J. Biomed. Mater. Res. 35, 399–406.CrossRefGoogle Scholar
  79. Jacobs, J., Urban, R.M., Gilbert, J.L., Skipor, A.K., Black, J., Jasty, M., Galante, J.O. 1995. Local and distant products from modularity, Clin. Orthop. 319, 94–105.Google Scholar
  80. Jacobs, J., Skipor, A., Doorn, P., Campbell, P., Schmalzried, T., Black, J., Amstutz, H. 1996. Cobalt and chromium concentrations in patients with metal on metal total hip replacements, Clin. Orthop. 3295, S256–S263.Google Scholar
  81. Jahns, G., Haeffner-Cavaillon, N., Nyddegger, U.E., Kazatchkine, M.D. 1993. Complement activation and cytokine production as consequences of immunological bioincompatibility of extracorporeal circuits, Clin. Mater. 14, 303–336.CrossRefGoogle Scholar
  82. Jarcho, M., 1981, Calcium phosphate ceramics as hard tissue prosthetics, Clin. Orthop. Relat. Res. 157, 259–278.Google Scholar
  83. Jia, W., Beatty, M.W., Reinhardt, R.A., Petro, T.M., Cohen, D.M. 1999. Nickel release from orthodontic arch wires and cellular immune response to various nickel concentrations, J. Biomed. Mater. Res. 48, 488–495.CrossRefGoogle Scholar
  84. Jiranek, W.J., Machado, M., Jasty, M., Jesevar, D., Wolfe, H.J., Goldring, S.R., Goldberg M.J., Harris, W.H. 1993. Production of cytokines around loosened cemented acetabular components. Analysis with immunohistochemical techniques and in situ hybridization, J. Bone Jt. Surg., Am. Vol. 75, 863–879.Google Scholar
  85. Kanagaraja, S., Lundstrom, I., Nygren, H., Tengvall, P. 1996. Platelet binding and protein adsorption to titanium and gold after short time exposure to heparinized plasma and whole blood, Biomaterials 17, 2225–2235.CrossRefGoogle Scholar
  86. Kane, DeHeer, D.H., Owens, S.R., Beebe, J.D., Swanson, A.B. 1994. Adsorption of collagenase to particulate titanium: a possible mechanism for collagenase localization in periprosthetic tissue, J. Appl. Biomater. 5, 353–360.CrossRefGoogle Scholar
  87. Kansas, G.S., 1992, Structure and function of L-selectin, APMIS 100, 287–293.CrossRefGoogle Scholar
  88. Kaplan, S.S., Basford, R.E., Kormos, R.L., Hardesty, R.L., Simmons, R.L., Mora, E.M., Cardona, M., Griffith, B.L. 1990. Biomaterial associated impairment of local neutrophil function, ASAIO Trans. 36, M172–175.Google Scholar
  89. Kaplan, S.S., Simmons, R.L. 1995. Neutrophil biomaterial interactions: implications for host defense and inflammation, in: Encyclopedic Handbook of Biomaterials and Bioengineering, Part A: Materials, Vol. 1 (D.L. Wise, D.J. Trantolo, D.E. Altobelli, M.J. Yaszemski, J.D. Gresser, E.R. Schwartz, eds.), pp. 457–491, Marcel Dekker, Inc., New York.Google Scholar
  90. Katou, F., Andoh, N., Motegi, K., Nagura, H. 1996. Immuno-inflammatory responses in the tissues adjacent to titanium miniplates used in the treatment of mandibular fractures, J. Craniomaxillofac. Surg. 24, 155–162.Google Scholar
  91. Kim, H., Johnson, J.W. 1999. Corrosion of stainless steel, nickel-titanium, coated nickeltitanium, and titanium orthodontic wires, Angle Orthod. 69, 39–44.Google Scholar
  92. Kim, K.J., Sato, K., Kotake, S., Katoh, Y., Itoh, T. 1993. Biochemical and histochemical analysis of bone marrow cells activated by HA particles, in: Bioceramics, Vol. 6 (P. Ducheyne, D. Christiansen, eds.), pp. 365–369, Butterworth-Heinemann Ltd., Philadelphia.Google Scholar
  93. Klein, C.L., Nieder, P., Wagner, M., Kohler, H., Bittinger, F., Kirkpatrick, C.J., Lewis, J.C. 1994. The role of metal corrosion in inflammatory processes: induction of adhesion molecules by heavy metal ions, J. Mater. Sci., Mater. Med. 5, 798–807.Google Scholar
  94. Klein, C.P., Driessen, A.A., de Groot, K. 1983a. Biodegradation behaviour of various calcium phosphate materials in bone tissue, J. Biomed. Mater. Res. 17, 769–784.CrossRefGoogle Scholar
  95. Klein, C.P., de Groot, K., van Kamp, G. 1983b. Activation of complement C3 by different calcium phosphate powders, Biomaterials 4, 181–184.CrossRefGoogle Scholar
  96. Korkusuz, F., Uluoglu, O. 1999. Non-specific inflammation and bone marrow depletion due to intramedullary porous hydroxyapatite application, Bull. Hosp. Jt. Dis. 58, 86–91.Google Scholar
  97. Kubo, T., Sawada, K., Hirakawa, K., Shimizu, C., Takamatsu, T., Hirasawa, Y. 1999. Histiocyte reaction in rabbit femurs to UHMWPE, metal, and ceramic particles in different sizes, J. Biomed. Mater. Res. 45, 363–369.CrossRefGoogle Scholar
  98. Labat, B., Chamson, A., Frey, C. 1995. Effects of γ-alumina and hydroxyapatite coatings on the growth and metabolism of human osteoblasts, J. Biomed. Mater. Res. 29, 1397–1401.CrossRefGoogle Scholar
  99. Lalor, P.A., Revell, P.A. 1993. T-lymphocytes and Titanium Aluminium Vanadium (TiA1Va) alloy: evidence for immunological events associated with debris deposition, Clin. Mater., 12, 57–62.CrossRefGoogle Scholar
  100. Le Huec, J.C., Schaeverbeke, T., Clement, D., Faber, J., Le Rebeller, A. 1995. Influence of porosity on the mechanical resistance of hydroxy-apatite ceramics under compressive stress, Biomaterials 16, 113–118.Google Scholar
  101. Lee, S.H., Brennan, F.R., Jacobs, J.J., Urban, R.M., Ragasa, D.R., Glant, T.T. 1997. Human monocyte/macrophage response to cobalt-chromium corrosion products and titanium particles in patients with total joint replacements, J. Orthop. Res. 15, 40–49.Google Scholar
  102. LeGeros, R.Z., Zheng, R., Kijkowska, R., Fan, D., LeGeros, J.P. 1994. Variations in composition and crystallinity of “hydroxyapatite (HA)” preparations, in: Characterization and Performance of Calcium Phosphate Coatings for Implants (E. Horowitz, J.E. Parr, eds.), pp. 45–53, ASTM STP 1196, American Society for Testing and Materials, Philadelphia.Google Scholar
  103. Lerouge, S., Huk, O., Yahia, L.H., Witvoet, J., Sedel, L. 1996. Characterization of in vivo wear debris from ceramic-ceramic total hip arthroplasties, J. Biomed. Mater. Res. 32, 627–633.CrossRefGoogle Scholar
  104. Lindholm, T.C., Gao, T.J., Lindholm, T.S. 1996. Time-related deviations of fibronectin and type I, II and III collagen on the interface between a hydroxyapatite disc and the rim of a calvarial trephine defect in rabbits, Biomaterials 17, 1515–1520.CrossRefGoogle Scholar
  105. Liu, H.C., Chang, W.H., Lin, F.H., Lu, K.H., Tsuang, Y.H., Sun, J.S. 1999. Cytokine and prostaglandin release from leukocytes in response to metal ions derived from different prosthetic materials: an in vitro study, Artif. Organs 23, 1099–1106.CrossRefGoogle Scholar
  106. Lohmann, C.H., Schwartz, Z., Zoster, G., Jahn, U., Buchhorn, G.H., MacDougall, M.J., Casasola, D., Liu, Y., Sylvia, V.L., Dean, D.D., Boyan, B.D. 2000. Phagocytosis and wear debris by osteoblasts affects differentiation and local factor production in a manner dependent on particle composition, Biomaterials, 21, 551–561.Google Scholar
  107. Lycott, R.W., Hughes, A.N. 1984. Corrosion, in: Metal and Ceramic Biomaterials, Vol. 2 (P. Ducheyne, G.W. Hastings, eds.) pp. 91–118, CRC Press, Boca Raton.Google Scholar
  108. MacNamara, A., Crowley, H.K., Williams, D.F. 1984. Metal-cell incubation products: chemotactic potential, in: Biomaterials and Biomechanics 1983, “Advances in Biomaterials 5” (P. Ducheyne, G. Van der Perre, A.E. Aubert, eds.), pp. 307–312, Elsevier Science Publishers B.V., Amsterdam.Google Scholar
  109. Malard, O., Bouler, J.M., Guicheux, J., Heymann, D., Pilet, P., Coquard, C., Daculsi, G. 1999. Influence of biphasic calcium phosphate granulometry on bone ingrowth, ceramic resorption, and inflammatory reactions: preliminary in vitro and in vivo study, J. Biomed. Mater. Res. 46, 103–111.CrossRefGoogle Scholar
  110. Maloney, W.J., James, R.E., Smith, R.L. 1996. Human macrophages response to retrieved titanium alloy particles in vitro, Clin. Orthop. 322, 268–278.Google Scholar
  111. Maloney, W.J., Sun, D.H., Nakashima, Y., James, R., Smith, R.L. 1998. Effects of serum protein opsonization on cytokine release by titanium-alloy particles, J. Biomed. Mater. Res. 41, 371–376.CrossRefGoogle Scholar
  112. Mangham, D.C., Scoones, D.J., Drayson, M.T. 1993. Complement and the recruitment of mononuclear osteoclasts, J. Clin. Pathol. 46, 517–521.Google Scholar
  113. Marchant, R., Hiltner, A., Hamlin, C., Rabinovitch, A., Slobodkin, R., Anderson, J.M. 1983. In vivo biocompatibility studies: I. The cage implant system and a biodegradable hydrogel, J. Biomed. Mater. Res. 17, 301–325.CrossRefGoogle Scholar
  114. McAlarney, M.E., Oshiro, M.A., McAlarney, C.V. 1996. Effects of titanium dioxide passive film crystal structure, thickness, and crystallinity on C3 adsorption, Int. J. Oral Maxillofac. Implants 11, 73–80.Google Scholar
  115. Mebius, R.E., Watson, S.R. 1993. Land E-selectin can recognize the same naturally occurring ligands on high endothelial venules, J. Immunol. 151, 3252–3360.Google Scholar
  116. Merkel, K.D., Erdmann, J.M., McHugh, K.P., Abu-Amer, Y., Ross, F.P., Teitelbaum, S.L. 1999. Tumor necrosis factor-alpha mediates orthopedic implant osteolysis, Am. J. Pathol. 154, 203–210.Google Scholar
  117. Merritt, K. 1986. Hypersensitivity induction, in Handbook of Biomaterials Evaluation (A.F. Von Recuum, ed.), pp. 179–187, Macmillan Publishing Company, New York.Google Scholar
  118. Merritt, K., Brown, S.A. 1985. Biological effects of corrosion products from metal, in: Corrosion and Degradation of Implant Materials (A.C. Fraker, C.D. Griffith, eds.), pp. 195–207, Second Symposium, ASTM STP 859, American Society for Testing and Materials, Philadelphia.Google Scholar
  119. Merritt, K., Brown, S.A. 1996. Distribution of cobalt chromium wear and corrosion products and biological reaction, Clin. Orthop. 329, S233–S243.Google Scholar
  120. Merritt, K., Mayor, M.B., Brown, S.A. 1980. Evaluation of sensitivity to metallic implants, in: Evaluation of Biomaterials (G. D. Winter, J.L. Leray, K. de Groot, eds.), pp. 315–324, J.Wiley & Sons, New York.Google Scholar
  121. Mu, Y., Kobayashi, T., Sumita, M., Yamamoto, A., Hanawa, T. 2000, Metal ion release from titanium with active oxygen species generated by rat macrophages in vitro, J. Biomed. Mater. Res. 49, 238–243.CrossRefGoogle Scholar
  122. Nagase, M. 1985. Antigenicity of alumina ceramic and calcium phosphate ceramics-genetic control of the immune response, Nippon Seikeigeka Gakkai Zasshi 59, 183–191.Google Scholar
  123. Nakashima, Y., Sun, D.H., Trindade, M.C., Chun, L.E., Song, Y., Goodman, S.B., Schurman, D.J., Maloney, W.J., Smith, R.L. 1999a. Induction of macrophage C-C chemokine expression by titanium alloy and bone cement particles, J. Bone Jt. Surg., Br. Vol. 81, 155–162.Google Scholar
  124. Nakashima, Y., Sun, D.H., Trindade, M.C., Maloney, W.J., Goodman, S.B., Schurman, D.J., Smith, R.L. 1999b. Signaling pathways for tumor necrosis factor-alpha and interleukin-6 expression in human macrophages exposed to titanium-alloy particulate debris in vitro, J. Bone Jt. Surg., Am. Vol. 81, 603–615.Google Scholar
  125. Nelson, R.D., Quie, P.G., Simmons, R.L. 1975. Chemotaxis under agarose, a new and simple method for measuring chemotaxis and spontaneous migration of human polymorphonuclear leukocytes and monocytes, J. Immunol. 115, 1650–1656.Google Scholar
  126. Neo, M., Nakamura, T., Ohtsuki, C, Kokubo, T., Yamamuro, T. 1993. Apatite formation on three kinds of bioactive materials at an early stage in vivo: a comparative study by transmission electron microscopy, J. Biomed. Mater. Res. 27, 999–1006.Google Scholar
  127. Nichols, K.G., Puleo, D.A. 1997. Effect of metal ions on the formation and function of osteoclastic cells in vitro, J. Biomed. Mater. Res. 35, 265–271.CrossRefGoogle Scholar
  128. Nordsletten, L., Hogasen, A.K.M., Konttinen, Y.T., Santavirta, S., Aspenberg, P., Aasen, A.O. 1996. Human monocytes stimulation by particles of hydroxyapatite, silicon carbide and diamond: in vitro studies of new prosthesis coatings, Biomaterials 17, 1521–1527.CrossRefGoogle Scholar
  129. Papatheofanis, F.J., Barmada, R. 1991. Polymorphonuclear leukocyte degranulation with exposure to polymethylmethacrylate nanoparticles, J. Biomed. Mater. Res. 25, 761–771.CrossRefGoogle Scholar
  130. Pazzaglia, U.E., Ghisellini, F., Barbieri, D., Ceciliani, L. 1988. Failure of the stem in total hip replacement. A study of aetiology and mechanism of failure in 13 cases, Arch. Orthop. Trauma Surg. 107, 195–202.CrossRefGoogle Scholar
  131. Petty, W. 1978. The effect of methylmethacrylate on chemotaxis of polymorphonuclear leucocytes, J. Bone Jt. Surg. 60, 492–497.Google Scholar
  132. Picker, L.J., Treer, J.R., Ferguson-Darnell, B., Collins, P.A., Bergstresser, P.R., Terstappen L.W.M.M. 1993. Control of lymphocyte recirculation in man. II. Differential regulation of the cutaneous lymphocyte associated antigen, a tissue-selective homing receptor for skin homing T-cell, J. Immunol. 150, 1122–1136.Google Scholar
  133. Pitzalis, C., Cauli, A., Pipitone, N., Smith, C., Barker, J., Marchesoni, A., Yanni, G., Panayi, G.S. 1996. Cutaneous lymphocytes antigen-positive T lymphocytes preferentially migrate to the skin but not the joint in psoriatic arthritis, Arthritis Rheum. 39, 137–145.Google Scholar
  134. Pizzoferrato, A., Vespucci, A., Tarabusi, C., Ciapetti, G., Stea, S. 1984. Chemotactic response of macrophages from biomaterial injected mice, in: Biomaterials and Biomechanics 1983, Advances in Biomaterials 5 (P. Ducheyne, G. Van der Perre, A.E. Aubert, eds.), pp. 301–306, Elsevier Science Publishers B.V., Amsterdam.Google Scholar
  135. Pizzoferrato, A. Vespucci, S., Ciapetti, G., Stea, S. 1986. Chemotactic behavior of macrophages under biomaterial influence, in: Techniques of Biocompatibility Testing, Vol. II (D.F. Williams, ed.), pp. 110–121, CRC Press, Inc., Boca Raton.Google Scholar
  136. Pizzoferrato, A., Vespucci, A., Ciapetti, G., Stea, S., Tarabusi, C. 1987. The effect of injections of powdered biomaterials on mouse peritoneal cell populations, J. Biomed. Mater. Res. 21, 419–428.CrossRefGoogle Scholar
  137. Pizzoferrato, A., Ciapetti, G., Stea, S., Toni, A. 1991. Cellular events in the mechanisms of prosthesis loosening, Clin Mater. 7, 51–81.CrossRefGoogle Scholar
  138. Pollice, P.F., Hsu, J., Hicks, D.G., Bukata, S., Rosier, R.N., Reynolds, P.R., Puzas, J.E., O’Keefe, R.J. 1998. Interleukin-10 inhibits cytokine synthesis in monocytes stimulated by titanium particles: evidence of an anti-inflammatory regulatory pathway, J. Orthop. Res. 16, 697–704.CrossRefGoogle Scholar
  139. Prabhu, A., Shelburne, C.E., Gibbons, D.F. 1998. Cellular proliferation and cytokine responses of murine macrophage cell line J774A.1 to polymethylmethacrylate and cobalt-chrome alloy particles, J. Biomed. Mater. Res. 42, 655–663.CrossRefGoogle Scholar
  140. Rader, C.P., Sterner, T., Jakob, F., Schutze, N., Eulert, J. 1999a. Cytokine response of human macrophage-like cells after contact with polyethylene and pure titanium particles, J. Anhroplasty 14, 840–848.Google Scholar
  141. Rader, C.P., Baumann, B., Sterner, T., Rolf, O., Hendrich, C, Schultze, N., Jakob, F. 1999b. secretion by human macrophage-like cells in response to wear particles and its modification by drugs, Biomed. Tech. (Berl.) 44, 135–141.Google Scholar
  142. Radin, S. and Ducheyne, P. 1994. Changes in characteristics arising from processing and the effect on in-vitro stability of calcium phosphate ceramics, in: Characterization and Performance of Calcium Phosphate Coatings for Implants, (E. Horowitz, J.E. Parr, eds.) pp. 111–123, ASTM STP 1196, American Society for Testing and Materials, Philadelphia.Google Scholar
  143. Ragab, A.A., Van De Motter, R., Lavish, S.A., Goldberg, V.M., Ninomiya, J.T., Carlin, C.R., Greenfield, E.M. 1999. Measurement and removal of adherent endotoxin from titanium particles and implant surfaces, J. Orthop. Res. 17, 803–809.CrossRefGoogle Scholar
  144. Ramsey, W.S. 1972. Analysis of individual leucocyte behaviour during chemotaxis, Exp. Cell Res. 70, 129–139.CrossRefGoogle Scholar
  145. Remes, A., Williams, D.F. 1991a. Neutrophil polarization and immunoelectrophoresis assay in the study of complement activation by biomaterials, Biomaterials 12, 607–613.Google Scholar
  146. Remes, A., Williams, D.F. 1991b. Relationship between chemotaxis and complement activation by ceramic biomaterials, Biomaterials, 12, 661–667.Google Scholar
  147. Remes, A., Williams, D.F. 1992. Immune response in biocompatibility, Biomaterials 13, 731–743.CrossRefGoogle Scholar
  148. Rodgers, K., Klykken, P., Jacobs, J., Frondoza, C., Tomazic, V., Zelikoff, J. 1997. Immunotoxicity of medical devices, Fund. Appl. Tox. 36, 1–14.Google Scholar
  149. Rogers, S.D., Howie, D.W., Graves, S.E., Pearcy, M.J., Haynes, D.R. 1997. In vitro human monocytes response to wear particles of titanium alloy containing vanadium or niobium, J. Bone Jt. Surg., Br. Vol. 79, 311–315.Google Scholar
  150. Romagnani, S. 1992. Induction of Thl and Th2 response, a key role for the immune response? Immunol. Today 13, 379–381.CrossRefGoogle Scholar
  151. Rooker, G.D., Wilkinson, J.D. 1980. Metal sensitivity in patients undergoing hip replacement. A prospective study, J. Bone Jt. Surg., Br. Vol. 62, 502–505.Google Scholar
  152. Rose, N.R. 1997. Immunologic diagnosis of autoimmune disease, in: Handbook of Human Immunology, (M.S. Lefell, A.D. Donnenberg, N.R. Rose, eds.), pp. 111–123, CRC Press, Boca Raton.Google Scholar
  153. Ross, L., Benghuzzi, H., Tucci, M., Callender, M., Cason, Z., Spence, L. 1996. The effect of HA, TCP and ALCAP bioceramic capsules on the viability of human monocyte and monocyte derived macrophages, Biomed. Sci. Instrum. 32, 71–79.Google Scholar
  154. Rostoker, G., Robin, J., Binet, O., Blamoutier, J., Paupe, J., Leissana Leibowitch, M., Beduelle, J., Sonneck, J.M., Garrel, J.B., Millet P. 1987. Dermatitis due to orthopedic implants. A review of the literature and report of three cases, J. Bone Jt. Surg., Am. Vol. 9, 1408–1412.Google Scholar
  155. Rovira, A., Amedee, J., Bareille, R., Rabaud, M. 1996. Colonization of a calcium phosphate/ elastin-solubilized peptide-collagen composite material by human osteoblasts, Biomaterials 17, 1535–1540.CrossRefGoogle Scholar
  156. Sabokbar, A., Pandey, R., Quinn, J.M., Athanasou, N.A. 1998. Osteoclastic differentiation by mononuclear phagocytes containing biomaterial particles, Arch. Orthop. Trauma Surg. 117, 136–140.CrossRefGoogle Scholar
  157. Sasaoka, K, Seto, K, Tsugita, M., Tsuru, S. 1989. An immunological study of tricalcium phosphate supplied by three different manufacturers, J. Clin. Lab. Immunol. 30, 197–202.Google Scholar
  158. Savarino, L., Granchi, D., Ciapetti, G., Stea, S., Donati, M.E., Zinghi, G., Fontanesi, G., Rotini, R., Montanaro, L. 1999. Effects of metal ions on white blood cells of patients with failed total joint arthroplasties, J. Biomed. Mater. Res. 47, 543–550.CrossRefGoogle Scholar
  159. Savio, J.A., Overcamp, L.M., Black, J. 1994. Size and shape of biomaterial wear debris, Clin. Mater. 15, 101–147.Google Scholar
  160. Schedle, A., Samorapoompichit, P., Rausch-Fan, X.H., Franz, A., Füreder, W., Sperr, W.R., Sperr, W., Ellinger, A., Slavicek, R., Boltz-Nitulescu, G., Valent, P. 1995. Response of L929 fibroblast, human gingival fibroblasts and human tissue mast cells to various metal cations, J. Dent. Res. 74, 1513–1515.Google Scholar
  161. Schedle, A., Samorapoompichit, P., Füreder, W., Rausch-Fan, X.H., Franz, A., Sperr, W.R., Sperr, W., Slavicek, R., Simak, S., Klepekto, W., Ellinger, A., Ghannadan, M., Baghes-tanian, M., Valent, P. 1998. Metal ion-induced toxic histamine release from human basophils and mast cells, J. Biomed. Mater. Res. 39, 560–567.CrossRefGoogle Scholar
  162. Shahgaldi, B.F., Heatley F.W., Dewar A., Corrin, B. 1995. In vivo corrosion of cobalt-chromium and titanium wear particles. J. Bone Jt. Surg., Br. Vol. 77, 962–966.Google Scholar
  163. Shanbhag, A., Jacobs, J.J., Black, J., Galante, J.O., Glant, T.T. 1994. Macrophage/particle interactions: effect of size, composition and surface area, J. Biomed. Mater. Res. 28, 81–90.CrossRefGoogle Scholar
  164. Shanbhag, A., Jacobs, J.J., Black, J., Galante, J.O., Glant, T.T. 1995. Human monocyte response to particulate biomaterials generated in vivo and in vitro, J. Orthop. Res. 13, 792–801.CrossRefGoogle Scholar
  165. Stea, S., Visentin, M., Granchi, D., Melchiorri, C., Soldati, S., Sudanese, A., Toni, A., Montanaro, L., Pizzoferrato, A. 1999. Wear debris and cytokine production in the interface membrane of loosened prostheses, J. Biomat. Sci., Polym. Ed. 10, 236–247.Google Scholar
  166. Stea, S., Visentin, M., Granchi, D., Cenni, E., Ciapetti, G., Sudanese, A., Toni, A. 2000, Apoptosis in peri-implant tissue, Biomaterials 21, 1393–1398.CrossRefGoogle Scholar
  167. Stern, I.J., Kapsalis, A.A., DeLuca, B.L., Pieczynski, W. 1972. Immunogenic effects of foreign materials on plasma proteins, Nature 238, 151–152.CrossRefGoogle Scholar
  168. Sun, Z.L., Wataha, J.C., Hanks, C.T. 1997. Effects of metal ions on osteoblast-like cell metabolism, J. Biomed. Mater. Res. 34, 29–37.Google Scholar
  169. Takebe, J., Itoh, S., Ariake, T., Shioji, H., Shioyama, T., Ishibashi, K., Ishizawa, H. 1998. The effect on immunocytes of anodic oxide titanium after hydrothermal treatment, J. Biomed. Mater. Res. 42, 272–277.CrossRefGoogle Scholar
  170. Tang, L., Eaton, J.W. 1993. Fibrin(ogen) mediates acute inflammatory responses to biomaterials, J. Exp. Med. 178, 2147–2156.CrossRefGoogle Scholar
  171. Tang, L., Jennings, T.A., Eaton, J.W. 1998. Mast cell mediate acute inflammatory responses to implanted biomaterials, Proc. Natl. Acad. Sci. USA 95, 8841–8846.Google Scholar
  172. Thompson, G.J., Puleo, D.A. 1995. Effects of sublethal metal ion concentrations on osteogenic cells derived from bone marrow stromal cells, J. Appl. Biomater. 6, 249–258.CrossRefGoogle Scholar
  173. Timbrell, J.A. 1991. Principles of Biochemical Toxicology, Taylor & Francis, London.Google Scholar
  174. Tofe, A.J., Brewster, G.A., Bowerman, M.A., Myers, R.N., Hurson, S.M. 1994. Hydroxylapatite powders for implant coatings, in: Characterization and Performance of Calcium Phosphate Coatings for Implants (E. Horowitz, J.E. Parr, eds.), pp. 9–15, ASTM STP 1196, American Society for Testing and Materials, Philadelphia.Google Scholar
  175. Tomei, L.D., Cope, F.O. (eds.), 1991. Apoptosis: The Molecular Basis of Cell Death, Curent communication on cell and molecular biology, Vol. 3, Cold Spring Arbor, NY.Google Scholar
  176. Toumbis, C.A., Kronick, J.L., Wooley, P.H., Nasser S. 1997. Total joint arthroplasty and the immune response, Semin. Arthritis Rheum. 27, 44–47.CrossRefGoogle Scholar
  177. Trindade, M.C., Nakashima, Y., Lind, M., Sun, D.H., Goodman, S.B., Maloney, W.J., Schurman, D.J., Smith R.L. 1999. Interleukin-4 inhibits granulocyte-macrophage colony-stimulating factor, interleukin-6, and tumor necrosis factor-alpha expression by human monocytes in response to polymethyl methacrylate particle challenge in vitro, J. Orthop. Res. 17, 797–802.CrossRefGoogle Scholar
  178. U.S. Department of Health and Human Services, Food and Drug Administration—Center for Devices and Radiological Health, Guidance for industry and FDA reviewers, Immunotoxicity Testing Guidance, Document issued on May 6, 1999, Pages 1–16.Google Scholar
  179. Van Raemdonck, W., Ducheyne, P., De Meester, P. 1984. Calcium-phosphate ceramics, in: Metal and Ceramic Biomaterials, Vol. II, Strength and Surface (P. Ducheyne, G.W. Hastings, eds.), pp. 143–166, CRC Press, Boca Raton.Google Scholar
  180. Vermes, I., Haanen, C, Steffen-Nakken, H., Reutelingsperger, C. 1995, A novel assay for apoptosis. Flow cytometric detection of phosphatidylserine expression on early apoptotic cells using fluorescein labelled Annexin V, J. Immunol. Methods 184, 39–51.CrossRefGoogle Scholar
  181. Vitale, M., Neri, L.M., Comani, S., Falcieri, E., Rizzoli, R., Rana, R., Papa, S. 1989. Natural killer function in flow cytometry. II. Evaluation of NK lytic activity by means of target cell morphological changes detected by right angle light scatter, J. Immunol. Methods 121, 115–120.CrossRefGoogle Scholar
  182. Vroman, L., Adams, A.L., Brakman, M. 1985. Lack of exchange among plasma proteins in narrow spaces on glass, demonstrated with metal oxide coatings, Haemostasis 15, 300–303.Google Scholar
  183. Wagner, M., Klein, C.L., van Kooten, T.G., Kirkpatrick, C.J. 1998. Mechanisms of cell activation by heavy metal ions, J. Biomed. Mater. Res. 42, 443–452.CrossRefGoogle Scholar
  184. Walivaara, B., Askendal, A., Krozer, A., Lundstrom, I., Tengvall, P. 1996. Blood protein interactions with chromium surfaces, J. Biomater. Sci., Polym. Ed. 81, 49–62.Google Scholar
  185. Wang, J.S., Goodman, S., Aspenberg, P. 1994. Bone formation in the presence of phagocytosable hydroxyapatite particles, Clin Orthop. 304, 272–279.Google Scholar
  186. Wang, J.Y., Tsukayama, D.T., Wicklund, B.H., Gustilo, R.B. 1996. Inhibition of T and B cell proliferation by titanium, cobalt, and chromium: role of IL-2 and IL-6, J. Biomed. Mater. Res. 32, 655–661.CrossRefGoogle Scholar
  187. Wang, J.Y., Wicklund, B.H., Gustilo, R.B., Tsukayama D.T. 1997a. Prosthetic metals impair murine immune response and cytokine release in vivo and in vitro, J. Orthop. Res. 15, 688–699.CrossRefGoogle Scholar
  188. Wang, W., Ferguson, D.J., Quinn, J.M., Simpson, A.H., Athanasou, N.A. 1997b. Biomaterial particle phagocytosis by bone-resorbing osteoclasts, J. Bone Jt. Surg., Br. Vol. 79, 849–856.Google Scholar
  189. Williams, D.F. 1982. Tissue reaction to metallic corrosion products and wear particles in clinical orthopaedics, in: Biocompatibility of Orthopaedic Implants, Vol. I (D.F. Williams, ed.), CRC Press, Inc., Boca Raton.Google Scholar
  190. Williams, D.F., Black, J., Doherty, P.J. 1993. Second consensus conference on definitions in biomaterials, in: Biomaterial-Tissue Interfaces: Advances in Biomaterials, Vol 107 (P.J. Doherty, D.F. Williams, eds.), pp. 525–533, Elsevier Applied Science, London.Google Scholar
  191. Winter, G.D. 1974. Tissue reactions to metallic wear and corrosion products in human patients, J. Biomed. Mater. Res. 5, 11–26.Google Scholar
  192. Wooley, P.H., Nasser, S., Fitzgerald, R.H. Jr. 1996. The immune response to implant materials in humans, Clin. Orthop. 326, 63–70.Google Scholar
  193. Wooley, P.H., Petersen, S., Song, Z., Nasser, S. 1997. Cellular immune response to orthopedic implant materials following cemented total joint replacement, J. Orthop. Res. 15, 874–880.CrossRefGoogle Scholar
  194. Wuyts, P., Proost, W., Put, J., Lenaerts, P., Paemen, L., Van Damme, J. 1994. Leukocyte recruitment by monocyte chemotactic proteins (MCPs) secreted by human phagocytes, J. Immunol. Methods 174, 237–247.CrossRefGoogle Scholar
  195. Yamaji, K., Yamane, S., Niimi, Y., Sueoka, A., Nose, Y. 1997. Strategy of leukocyte filtration for immunomodulation: development of stainless steel leukocyte filter, Ther. Apher. 1, 63–66.Google Scholar
  196. Yang, J., Merritt, K. 1994. Detection of antibodies against corrosion products in patients after Co-Cr total joint replacements, J. Biomed. Mater. Res. 28, 1249–1258.CrossRefGoogle Scholar
  197. Yang, J., Merritt, K. 1996. Production of monoclonal antibodies to study corrosion products of CoCr biomaterials, J. Biomed. Mater. Res. 31, 71–80.Google Scholar
  198. Zigmond, S.H., Hirsch, J.G. 1973. Leukocyte locomotion and chemotaxis. New method for evaluation, and demonstration of a cell-derived chemotactic factor, J. Exp. Med. 137, 387–410.CrossRefGoogle Scholar

Copyright information

© Kluwer Academic Publishers 2002

Authors and Affiliations

  • Arturo Pizzoferrato
    • 1
  • Elisabetta Cenni
    • 1
  • Gabriela Ciapetti
    • 1
  • Donatella Granchi
    • 1
  • Lucia Savarino
    • 1
  • Susanna Stea
    • 1
  1. 1.Laboratorio di Fisiopatologia degli Impianti OrtopediciIstituti Ortopedici RizzoliBolognaItaly

Personalised recommendations