Abstract

India is currently importing different types of medical implants and devices, which cost about 0.65 million USD. Most of the imported implants and devices are found to be expensive and not suitable for Indian patients because of their design limitations. Thus, it is very much essential to develop indigenous devices at an affordable cost without compromising their functional activities. The chapter will discuss the design and development of patient-specific biomedical devices and implants as per ISO/ASTM standards in order to meet their individual requirements. In the specified area, the products being developed by our research team have been kept under two different categories namely implants and biomedical devices. Under the implant category, the products such as (i) ultrahigh molecular weight polyethylene-based acetabular cup, (ii) 3D printed shape memory polyurethane-based aneurysm coil, and (iii) different types of cerium-based anti-scavenging materials to absorb the excess reactive oxygen species (ROS) to preserve the residual hearing after cochlear implant fixation are being developed and tested. In case of biomedical devices, prosthetic and orthotic devices such as (i) polymer-based polycentric knee joint, (ii) dynamic foot, (iii) custom-made ankle-foot orthosis, (iv) suction and suspension incorporated socket for lower limb amputees, and (v) direct socket fabrication system are being developed and trialled. A discussion on the different materials including polymers, ceramic, and composites which are used to improve the performance of the above-discussed biomedical devices and implants will be deliberated in details.

Keywords

Shape-memory polymer  Aneurysm Lower limb Prosthesis Orthosis Knee joint 

References

  1. 1.
    Wang W, Lin R, Stark C, Dumbleton JH (1999) Suitability and limitations of carbon fiber reinforced PEEK composites as bearing surfaces for total joint replacements. Wear 225:724–727.  https://doi.org/10.1016/S0043-1648(99)00026-5CrossRefGoogle Scholar
  2. 2.
    Zoo YS, An JW, Lim DP, Lim DS (2003) Effect of carbon nanotube addition on tribological behavior of UHMWPE. Tribol Lett 16:305–309.  https://doi.org/10.1023/B:TRIL.0000015206.21688.87CrossRefGoogle Scholar
  3. 3.
    Wang Q, Zhang D, Ge S (2007) Biotribological behavior of ultra-high molecular weight polyethylene composites containing Ti in a hip joint simulator. Proc Inst Mech Eng J-J Eng 221:307–313.  https://doi.org/10.1243/13506501JET232CrossRefGoogle Scholar
  4. 4.
    Liu JL, Zhu YY, Wang QL, Ge SR (2008) Biotribological behavior of Ultra high molecular weight polyethylene composites containing bovine bone hydroxyapatite. J China Univ Min Technol 18:606–612.  https://doi.org/10.1016/S1006-1266(08)60303-XCrossRefGoogle Scholar
  5. 5.
    Ge S, Wang S, Huang X (2009) Increasing the wear resistance of UHMWPE acetabular cups by adding natural biocompatible particles. Wear 267:770–776.  https://doi.org/10.1016/j.wear.2009.01.057CrossRefGoogle Scholar
  6. 6.
    Plumlee K, Schwartz CJ (2009) Improved wear resistance of orthopaedic UHMWPE by reinforcement with zirconium particles. Wear 267:710–717.  https://doi.org/10.1016/j.wear.2008.11.028CrossRefGoogle Scholar
  7. 7.
    Borruto A (2010) A new material for hip prosthesis without considerable debris release. Med Eng Phys 32:908–913.  https://doi.org/10.1016/j.medengphy.2010.06.007CrossRefGoogle Scholar
  8. 8.
    Wood WJ, Maguire RG, Zhong WH (2011) Improved wear and mechanical properties of UHMWPE–carbon nanofiber composites through an optimized paraffin-assisted melt-mixing process. Compos B Eng 42:584–591.  https://doi.org/10.1016/j.compositesb.2010.09.006CrossRefGoogle Scholar
  9. 9.
    Tai Z, Chen Y, An Y, Yan X, Xue Q (2012) Tribological behavior of UHMWPE reinforced with graphene oxide nanosheets. Tribol Lett 46:55–63.  https://doi.org/10.1007/s11249-012-9919-6CrossRefGoogle Scholar
  10. 10.
    Colon J, Herrera L, Smith J, Patil S, Komanski C, Kupelian P, Seal S, Jenkins DW, Baker CH (2009) Protection from radiation-induced pneumonitis using cerium oxide nanoparticles. Nanomed Nanotechnol Biol Med 5:225–231.  https://doi.org/10.1016/j.nano.2008.10.003CrossRefGoogle Scholar
  11. 11.
    Chen J, Patil S, Seal S, McGinnis JF (2006) Rare earth nanoparticles prevent retinal degeneration induced by intracellular peroxides. Nat Nanotechnol 1:142–150.  https://doi.org/10.1038/nnano.2006.91CrossRefGoogle Scholar
  12. 12.
    Hewlings S, Kalman D (2017) Curcumin: a review of its effects on human health. Foods 6:92.  https://doi.org/10.3390/foods6100092CrossRefGoogle Scholar
  13. 13.
    Lee SS, Song W, Cho M, Puppala HL, Nguyen P, Zhu H, Segatori L, Colvin VL (2013) Antioxidant properties of cerium oxide nanocrystals as a function of nanocrystal diameter and surface coating. ACS Nano 7:9693–9703.  https://doi.org/10.1021/nn4026806CrossRefGoogle Scholar
  14. 14.
    Tsai YY, Oca-Cossio J, Lin SM, Woan K, Yu PC, Sigmund W (2008) Reactive oxygen species scavenging properties of ZrO2–CeO2 solid solution nanoparticles. Nanomedicine 3:637–645.  https://doi.org/10.2217/17435889.3.5.637CrossRefGoogle Scholar
  15. 15.
    Eriksson P, Tal AA, Skallberg A, Brommesson C, Hu Z, Boyd RD, Olovsson W, Neal Fairley, Abrikosov IA, Zhang X, Uvdal K (2018) Cerium oxide nanoparticles with antioxidant capabilities and gadolinium integration for MRI contrast enhancement. Sci Rep 8:1–12.  https://doi.org/10.1038/s41598-018-25390-zCrossRefGoogle Scholar
  16. 16.
    Li X, Zhao G, Zhang J, Duan Z, Xin S (2013) Prevalence and trends of the abdominal aortic aneurysms epidemic in general population—a meta-analysis. PLoS One 8:1–11.  https://doi.org/10.1371/journal.pone.0081260CrossRefGoogle Scholar
  17. 17.
    Qureshi AI, Janardhan V, Hanel RA, Lanzino G (2007) Comparison of endovascular and surgical treatments for intracranial aneurysms: an evidence-based review. Lancet Neurol 6:816–825.  https://doi.org/10.1016/S1474-4422(07)70217-XCrossRefGoogle Scholar
  18. 18.
    Vaidya S, Tozer KR, Chen J (2008) An overview of embolic agents. Semin Intervent Radiol 25:204–215.  https://doi.org/10.1055/s-0028-1085930CrossRefGoogle Scholar
  19. 19.
    Kashyap D, Kumar PK, Kanagaraj S (2018) 4D printed porous radiopaque shape memory polyurethane for endovascular embolization. Addit Manuf 24:687–695.  https://doi.org/10.1016/j.addma.2018.04.009CrossRefGoogle Scholar
  20. 20.
    Ohki T, Ni QQ, Ohsako N, Iwamoto M (2004) Mechanical and shape memory behavior of composites with shape memory polymer. Compos Part A Appl Sci Manuf 35:1065–1073.  https://doi.org/10.1016/j.compositesa.2004.03.001CrossRefGoogle Scholar
  21. 21.
    Ranger BJ, Mantzavinou A (2017) A course in prosthetics for the developing world: Merging education, research, and industry to teach biomedical design for social impact. In: Engineering in Medicine and Biology Society (EMBC), 39th annual international conference of the IEEE, pp 30–33. doi:978-1-5090-2809-2/17Google Scholar
  22. 22.
    Prosthetic and Orthotic Care (2017) Available on http://www.pandocare.com/transfemoral-knee-disarticulation/. Accessed on 08 Jan 2019
  23. 23.
    Physiopedia (2018) Available at. https://www.physio-pedia.com. Accessed on 25 Oct 2018
  24. 24.
    Ali S, Osman NAA, Naqshbandi MM, Eshraghi A, Kamyab M, Gholizadeh H (2012) Qualitative study of prosthetic suspension systems on transtibial amputees’ satisfaction and perceived problems with their prosthetic devices. Arch Phys Med Rehabil 93:1919–1923.  https://doi.org/10.1016/j.apmr.2012.04.024CrossRefGoogle Scholar
  25. 25.
    Ossur Life Without Limitation. Available at https://www.ossur.com/prosthetic-soliutions/liner-sleeves. Accessed on 6 Aug 2018
  26. 26.
    Gholizadeh H, Osman NAA, Eshragji A, Ali S, Yahyavi ES (2013) Satisfaction and problems experienced with transfemoral suspension system: a comparison between the common suction socket and seal-in liner. Arch Phys Med Rehabil 94:1584–1589.  https://doi.org/10.1016/j.apmr.2012.12.00710CrossRefGoogle Scholar
  27. 27.
    Kahle JT, Orriola JJ, Johnston W, Highsmith MJ (2014) The effect of vacuum-assisted suspension on residual limb physiology, wound healing and function: a systematic review. Technol Innov 15:333–341.  https://doi.org/10.3727/194982413X13844488879177CrossRefGoogle Scholar
  28. 28.
    Digital Resource Foundation for the Orthotics and Prosthetics Community. Available at http://www.drfop.org. Accessed on 25 Dec 2018
  29. 29.
    Jin YA, Plott J, Chen R, Wensman J, Shin A (2014) Additive manufacturing of custom orthoses and prostheses—a review. Procedia CIRP 36:199–204.  https://doi.org/10.1016/j.addma.2016.04.002CrossRefGoogle Scholar
  30. 30.
    Clombo G, Filippi S, Rizzi C, Rotini F (2010) A new design paradigm for the development of custom-fit soft sockets for the lower prostheses. Comput Ind 61:513–523.  https://doi.org/10.1016/j.compind.2010.03.008CrossRefGoogle Scholar
  31. 31.
    Olafsson S, Ingimarsson G, Landry D (2014) Knee rotational adaptor. US Patent App. 14/175, 507Google Scholar
  32. 32.
    Wu X (2012) Rotation structure of knee joint of artificial limb. US Patent App. 13/228,472Google Scholar
  33. 33.
    Cavuto ML, Chun M, Kelsall N, Baranov K, Durhin K, Zho M, Winter AG (2016) Design of mechanism and preliminary field validation of low cost transfemoral rotator for the use in the developing world. ASME. 1–9.  https://doi.org/10.1115/detc2016-59913
  34. 34.
    Andrysek J, Naumann S, Cleghorn WL (2004) Design characteristics of pediatric prosthetic knees. IEEE Trans Neural Syst Rehabil Eng 12:369–378.  https://doi.org/10.1109/TNSRE.2004.838444CrossRefGoogle Scholar
  35. 35.
    Seid S, Sujatha S, Chnadramohan S (2015) Design of controller for single axis knee using hydraulic damper. Africon, 1–5.  https://doi.org/10.1109/afrcon.2015.7331868
  36. 36.
    Radcliffe CW (1977) The Knud Jansen lectur: above-knee prosthetics. Prosthet Orthot Int 1:146–160.  https://doi.org/10.3109/03093647709164629CrossRefGoogle Scholar
  37. 37.
    Radcliffe CW, Deg M (2003) Biomechanics of knee stability control with four-bar prosthetic knees. Int Soc Prosthet Orthot 2:290–298Google Scholar
  38. 38.
    Oberg K (1983) Knee mechanism for through knee prostheses. Prosthet Orthot Int 7:107–112.  https://doi.org/10.3109/03093648309146733CrossRefGoogle Scholar
  39. 39.
    Radcliffe CW (1994) Four-bar linkage prosthetic knee mechanisms: kinematics, alignment and prescription criteria. Prosthet Orthot Int 18:159–173.  https://doi.org/10.3109/03093649409164401CrossRefGoogle Scholar
  40. 40.
    Gramnaes L (2014) Combined active and passive leg prosthesis system and a method for performing a movement 119th such a system. Google Patents. US Patent 8814949Google Scholar
  41. 41.
    Jaiswal VK, Kumar A, Khatait J, Saha S (2015) Lower limb prosthetic device, BTP report. Department of Mechanical Engineering, Indian Institute of Technology, Delhi, 2015Google Scholar
  42. 42.
    Furse A, Cleghorn W, Andrysek J (2011) Improving the gait performance of nonfluid-based swing-phase control mechanisms in trans femoral prostheses. IEEE Biomed Eng 58:2352–2359.  https://doi.org/10.1109/TBME.2011.2155059CrossRefGoogle Scholar
  43. 43.
    Arun S, Kanagaraj S (2016) Injection moldable polymeric composite based passive polycentric joint. Google Patents. US Patent App. 14/840.052Google Scholar
  44. 44.
    Zeng Y (2009) Design and testing of a passive prosthetic ankle with mechanical performance similar to that of a natural ankle. Master’s thesis, Marquette UniversityGoogle Scholar
  45. 45.
    Kobayashi T, Leung AK, Akazawa Y, Hutchins SW (2013) The effect of varying the plantarflexion resistance of an ankle-foot orthosis on knee joint kinematics in patients with stroke. Gait Posture 37:457–459.  https://doi.org/10.1016/j.gaitpost.2012.07.028CrossRefGoogle Scholar
  46. 46.
    Muhammad I, Rakib I, Ahmed C, Sajjad H, Noor A, Abu O (2015) Design and biomechanical performance analysis of a user-friendly orthotic device. Mater Des 65:716–725CrossRefGoogle Scholar
  47. 47.
    Daniel PF, Joseph MC, Blake H (2005) An ankle-foot orthosis powered by artificial muscles. J Appl Biomech 21:189–197CrossRefGoogle Scholar
  48. 48.
    Blaya JA, Herr H (2004) Adaptive control of a variable-impedance ankle-foot orthosis to assst drop-foot gait. IEEE Trans Neural Sys Rehabil Eng 12:24–31.  https://doi.org/10.1109/TNSRE.2003.823266CrossRefGoogle Scholar
  49. 49.
    Morshed A, Imtiaz AC, Azuddin BM (2014) Mechanism and design analysis of articulated ankle foot orthoses for drop-foot. Sci World J 2014:14. Article ID: 867869.  https://doi.org/10.1155/2014/867869Google Scholar

Copyright information

© Springer Nature Singapore Pte Ltd. 2019

Authors and Affiliations

  • Devarshi Kashyap
    • 1
  • Vaibhav Jaiswal
    • 1
  • Subramani Kanagaraj
    • 1
    Email author
  1. 1.Department of Mechanical EngineeringIndian Institute of Technology GuwahatiNorth GuwahatiIndia

Personalised recommendations