Advertisement

SFC Orchestration Method Based on Energy Saving and Time Delay Optimization

  • Zanhong Wu
  • Zhan ShiEmail author
  • Ying Zeng
Conference paper
  • 2 Downloads
Part of the Advances in Intelligent Systems and Computing book series (AISC, volume 1143)

Abstract

For the network function virtualization (NFV) environment, the existing virtual network feature (VNF) placement algorithm is difficult to optimize network energy consumption and network delay. This paper constructs an NFV. The network energy consumption and processing delay cost model. The energy consumption in this model includes server energy consumption and link energy consumption. The delay includes processing delay and link transmission delay in the network. Based on this model, this paper proposes an optimization algorithm combining simplex method and genetic algorithm. The simulation results show that compared with the random mapping algorithm, the algorithm designed in this paper can optimize the network energy consumption while ensuring the quality of service.

Keywords

Network function virtualization Energy efficient Quality of service VNF deployment 

Notes

Acknowledgements

This work was supported by the science and technology project of Guangdong power grid (036000KK52160025).

References

  1. 1.
    Marotta, A., D’Andreagiovanni, F., Kassler, A., Zola, E.: On the energy cost of robustness for green virtual network function placement in 5G virtualized infrastructures. Comput. Netw. 125, 64–75 (2017)CrossRefGoogle Scholar
  2. 2.
    Shojafar, M., Cordeschi, N., Baccarelli, E.: Energy-efficient adaptive resource management for real-time vehicular cloud services. IEEE Trans. Cloud Comput. to be publishedGoogle Scholar
  3. 3.
    Ghaznavi, M., Shahriar, N., Kamali, S., Ahmed, R., Boutaba, R.: Distributed service function chaining. IEEE J. Sel. Areas Commun. 35(11), 2479–2489 (2017)CrossRefGoogle Scholar
  4. 4.
    Tang, M., Pan, S.: A hybrid genetic algorithm for the energy-efficient virtual machine placement problem in data centers. Neural Process. Lett. 41(2), 211–221 (2015)CrossRefGoogle Scholar
  5. 5.
    Jiang, J. W., Lan, T., Ha, S., Chen, M., Chiang, M.: Joint VM placement and routing for data center traffic engineering. In: Proceeding of IEEE INFOCOM, pp. 2876–2880 (2012)Google Scholar
  6. 6.
    Bhamare, D., Samaka, M., Erbad, A., et al.: Optimal virtual network function placement in multi-cloud service function chaining architecture. Comput. Commun. 102, 1–16 (2017)CrossRefGoogle Scholar

Copyright information

© Springer Nature Singapore Pte Ltd. 2021

Authors and Affiliations

  1. 1.Electric Power Dispatch & Control CenterGuangdong Power Grid Co., Ltd.GuangzhouChina

Personalised recommendations