Influence of Air Supply Outlet on Displacement Ventilation System for Relic Preservation Area in Archaeology Museum

  • Juan Li
  • Xilian LuoEmail author
  • Bin Chang
  • Zhaolin Gu
Conference paper
  • 181 Downloads
Part of the Environmental Science and Engineering book series (ESE)

Abstract

Displacement ventilation (DV) system is an energy-saving strategy for buildings with large-space layout. However, the application of this system to the relic preservation area in archaeology museum is facing challenges since there no internal heat sources existed in the occupied area. The primary factors that affect the thermal stratification would be the arrangement of the supply air outlet and supplied air parameters. In this research, three experimental tests were carried out to evaluate the influence of the supply air outlet on the system performance. The experimental results show that the vertical distribution of the supply air outlet has a negligible effect on the temperature and relative humidity (RH) environment parameters in the inner area of the burial pit, but has a great influence on the upper region. That is to say, for the area with slightly higher cultural relic, the location of the supply air outlet should not be too low.

Keywords

Relic preservation Archaeology museum Displacement ventilation system Air supply outlet 

Notes

Acknowledgements

This study was supported by the Key Scientific Research Innovation Team Project of Shaanxi Province (under grant No.2016KCT-14), the Shaanxi Provincial Natural Science Foundation (2018JM5091) and the Fundamental Research Funds for the Central Universities (under grant No. zrzd2017003).

References

  1. 1.
    Dunham Inc. HVAC comparison study at 225 bush street San Francisco, Minneapolis, MN, USA. (1999)Google Scholar
  2. 2.
    Wang, X., et al.: Analysis of the influence of heat source characteristics on the thermal stratification height of displacement ventilation. Build. Therm. Energy Air Cond. 24(3), 72–75 (2005)Google Scholar
  3. 3.
    Park, H.J., Holland, D.: The effect of location of a convective heat source on displacement ventilation: CFD study. Build. Environ. 36(7), 883–889 (2001)CrossRefGoogle Scholar
  4. 4.
    Luo, X., Gu, Z., et al.: Experimental study of a local ventilation strategy to protect semi-exposed relics in a site museum. Energy Build. 159, 558–571 (2018)CrossRefGoogle Scholar
  5. 5.
    Manins, P.C.: Turbulent buoyant convection from a source in a confined region. J. Fluid Mech. 37(4), 51–80 (1969)Google Scholar
  6. 6.
    Linden, P.F., Lane-Serff, G.F., Smeed, D.A.: Emptying filling boxes: the fluid mechanics of natural ventilation. J. Fluid Mech. 212(2), 309–335 (1990)CrossRefGoogle Scholar
  7. 7.
    Lin, Y.J.P., Wu, J.Y.: A study on density stratification by mechanical extraction displacement ventilation. Int. J. Heat Mass Transf. 110, 447–459 (2017)CrossRefGoogle Scholar
  8. 8.
    Zhang, Z., et al.: In-situ conservation of cultural relics under multi-media coupling environment. J. Xi’an Jiaotong Univ. 11, 150–156 (2016)Google Scholar
  9. 9.
    Luo, X., Zhaolin, Gu, et al.: Desiccation cracking of earthen sites in archaeology museum—a viewpoint of chemical potential difference of water content. Indoor Built Environ. 24, 147–152 (2015)CrossRefGoogle Scholar
  10. 10.
    Viitanen, H., Vinha, J., Salminen, K., et al.: Moisture and bio-deterioration risk of building materials and structures. J. Build. Phys. 33(3), 201–224 (2010)CrossRefGoogle Scholar

Copyright information

© Springer Nature Singapore Pte Ltd. 2020

Authors and Affiliations

  • Juan Li
    • 1
    • 2
  • Xilian Luo
    • 1
    • 2
    Email author
  • Bin Chang
    • 1
    • 2
  • Zhaolin Gu
    • 1
    • 2
  1. 1.Shaanxi Environmental and Building Energy Conservation Engineering Technology Research CenterXi’an Jiaotong UniversityXi’anChina
  2. 2.School of Human Settlements and Civil EngineeringXi’an Jiaotong UniversityXi’anChina

Personalised recommendations