Experimental Study on Thermal Environment and Stratified Air-Conditioning Load of Scaled Model Laboratory with Low-Sidewall Air Supply under Step Thermal Disturbance

  • Chen HuangEmail author
  • Yufeng Miao
  • Yang Liu
  • Ruibin Li
  • Yuantao Xue
  • Haidong Wang
  • Fei Wang
Conference paper
  • 244 Downloads
Part of the Environmental Science and Engineering book series (ESE)

Abstract

Based on an engineering training centre, a scaled model laboratory with a geometric ratio of 1:4 was established. The indoor thermal environment and stratified air-conditioning load (SACL) of the scaled model laboratory with low-sidewall air supply was experimentally studied. The heat gain through the building envelope was simulated in the form of step thermal disturbance by the electric heating film attached to the walls and roof. The lab was commissioned by a series of pre-experiments, and seven experimental cases were conducted with different exhaust ratios and indoor heat source heights. The experimental results indicated that when the exhaust ratio was increased from 0 to 21.63%, the internal wall surface temperature was reduced by 2.85 °C, the indoor air temperature in the air-conditioned area was reduced by 0.84 °C and the SACL was reduced by 18.90%.

Keywords

Experimental study Indoor thermal environment Stratified air-conditioning load Low-sidewall air supply Step thermal disturbance 

Notes

Acknowledgements

The project is financially supported by the National Natural Science Foundation of China (51278302, 51508326) and the Shanghai Natural Science Foundation (16ZR1423200).

References

  1. 1.
    Gordon, R.L., Bagheri, M.: Verification of Stratified Air Condition Design. ASHRAE Report 388RP (1986)Google Scholar
  2. 2.
    Li, Y., Sandberg, M., Fuchs, L.: Vertical temperature profiles in rooms ventilated by displacement: full-scale measurement and nodal modelling. Indoor Air 243(2), 225–243 (1992)CrossRefGoogle Scholar
  3. 3.
    Nielsen, PV.: Temperature distribution in a displacement ventilated room. Proc. Roomvent 323–330 (1996)Google Scholar
  4. 4.
    Causone, F., Corgnati, S.P.: Experimental evaluation of heat transfer coefficients between radiant ceiling and room. Energy Build. 41(6), 622–628 (2009)CrossRefGoogle Scholar
  5. 5.
    Huang, C., et al.: Measurements of indoor thermal environment and energy analysis in a large space building in typical seasons. Build. Environ. 42(5), 1869–1877 (2007)CrossRefGoogle Scholar
  6. 6.
    Tovar, R., Linden, P.F.: Hybrid ventilation in two interconnected rooms with a buoyancy source. Sol. Energy 81(5), 683–691 (2007)CrossRefGoogle Scholar
  7. 7.
    Wang, H.D., et al.: On the calculation of heat migration in thermally stratified environment of large space building with sidewall nozzle air-supply. Build. Environ. 147, 221–230 (2019)CrossRefGoogle Scholar
  8. 8.
    Liu, P., et al.: Evaluation of buoyancy-driven ventilation in atrium buildings using computational fluid dynamics and reduced-scale air model. Build. Environ. 44(9), 1970–1979 (2009)CrossRefGoogle Scholar
  9. 9.
    Gao, J.: Research of the Theory of Thermal Stratification in Buildings and its Applications. Doctoral degree thesis, Harbin Institute of Technology (2007)Google Scholar

Copyright information

© Springer Nature Singapore Pte Ltd. 2020

Authors and Affiliations

  1. 1.School of Environment and ArchitectureUniversity of Shanghai for Science and TechnologyShanghaiChina
  2. 2.Tongji Architectural Design (Group) Co., Ltd.ShanghaiChina
  3. 3.Zhongliang Holdings GroupBeijingChina

Personalised recommendations