A Comparison of Thermal Comfort of People from Buildings with Centralized Air-Conditioning Systems and Split Air-Conditioners

  • Zhongjun Zhang
  • Yufeng ZhangEmail author
  • Adnan Khan
Conference paper
  • 234 Downloads
Part of the Environmental Science and Engineering book series (ESE)

Abstract

A comparative study on thermal comfort of people from buildings with central air-conditioning system (CAC buildings) and split air-conditioner (SAC buildings) was conducted in climate chamber. The experimental conditions covered a wide thermal sensation range from cool to hot, and both physiological and psychological responses were collected. The results showed that the mean skin temperature was significantly higher for subjects from CAC buildings in the non-neutral conditions, while the skin wettednes was no significant difference between the two groups. The subjects from CAC and SAC buildings reported the same thermal sensations, and their neutral temperatures (26.8 and 26.6 °C) and thermal sensitivities (both 0.31 °C-1) were not significantly different as well. The 90% thermal acceptable SET ranges were 24.8–27.4 °C for subjects from CAC buildings and 24.4–30.1 °C for subjects from SAC buildings. The thermal acceptable upper limit was 2.7 °C lower for subjects from CAC buildings. The possible impacts of thermal history and expectation are discussed.

Keywords

Air-conditioner Thermal adaptation Thermal history Expectation 

Notes

Acknowledgements

This work was supported by the National Nature Science Foundation of China [No. 51708228]; “The 13th Five-year” National Key R&D Program of China [No. 2018YFC0704500]; and State Key Laboratory of Subtropical Building Science, SCUT [No. 2019ZB16]. Thanks to the sixty subjects.

Informed Consent All subjects were informed of the experiment procedure and possible risks, experiments were carried out with their consent, and informed consent was obtained from all individual subjects. Experimental procedures performed in studies involving human participants were in accordance with the 1964 Helsinki declaration and its later amendments or comparable ethical standards.

References

  1. 1.
    Luo, M., Wang, Z., Brager, G., et al.: Indoor climate experience, migration, and thermal comfort expectation in buildings. Build. Environ. 141, 262–272 (2018)CrossRefGoogle Scholar
  2. 2.
    Zhang, Z., Zhang, Y., Jing, L.: Thermal comfort of rural residents in a hot–humid area. Build. Res. Inf. 45(1–2), 209–221 (2016)Google Scholar
  3. 3.
    Zhao, R.: Air condition. China Building Industry Press, Beijing (2010)Google Scholar
  4. 4.
    ASHARE: Handbook-Fundamentals, in Thermal Comfort. ASHRAE Inc., Atlanta (2009)Google Scholar

Copyright information

© Springer Nature Singapore Pte Ltd. 2020

Authors and Affiliations

  1. 1.School of Civil and Architectural EngineeringAnyang Institute of TechnologyAnyangChina
  2. 2.State Key Laboratory of Subtropical Building Science, Department of ArchitectureSouth China University of TechnologyWushan, GuangzhouChina

Personalised recommendations