Abstract

This essay analyzes the measurement of the power factor in the drive motor system of the frequency converter. Due to the fact that it is inconvenient to utilize the power analyzer to acquire the motor power factor directly. A method is proposed. We can collect the DC bus signal waveform. Then we the could reconstruct motor stator three-phase voltage and current to test indirectly the motor power factor. In addition, there are some simulations and data collected from experimental device in order to verifying accuracy. Congruously, the experimental results show that within a certain error range, the motor power factor can be measured by voltage and current reconstruction.

Keywords

DC bus voltage Phase voltage reconstruction Phase current reconstruction Power analysis Power factor 

References

  1. 1.
    Cheng, M., Jiang, Y., Wang, Q.: PWM inverter phase current reconstruction strategy for line voltage Modulation. J. Mot. Control 22(02), 9–16 (2018)Google Scholar
  2. 2.
    Chu, J., Hu, W., Huang, W., Yang, F.: A phase current sampling reconstruction technique for inverter. Trans China Electrotech. Soc. 25(01), 111–117 (2010)Google Scholar
  3. 3.
    Zhang, Y.: Application Technology of SPWM Frequency Conversion Speed Regulation. China Machine Press, p. 12 (2011)Google Scholar
  4. 4.
    Zeng, Y.: Principle, Algorithm and Application of SVPWM Technology of Variable Frequency Speed Regulation. China Machine Press, p. 10 (2010)Google Scholar
  5. 5.
    Gu, Y., Ni, F., Yang, D., Dang, J., Liu, H.: Phase current reconstruction method based on bus current sensor. J. Mot. Control 13(06), 811–816 (2009)Google Scholar
  6. 6.
    Zhang, J., Zhang, X., Chen, T., Peng, Y., Sun, Y., Tian, H.: Phase voltage reconstruction of synchronous motor and observation of magnetic chain. Electr. Driv. 43(08), 29–32 (2013)Google Scholar
  7. 7.
    Sun, X., Shang, Y., Zhong, Y., Zhang, W.: Research on output voltage reconstruction technology of three-phase voltage source inverter. J. Xi’an Univers. Technol. 02, 122–124 (2005)Google Scholar
  8. 8.
    Haga, H., Hara, Y., Kondo, S.: Method for Reconstructing Three-phase Voltage of Current Source Inverter via Detection of DC-link Voltage. Nagaoka University of Technology (2012)Google Scholar
  9. 9.
    Wang, W.: Research on High Precision Reactive Power Measurement. Southwest JiaoTong University (2007)Google Scholar
  10. 10.
    Fiorucci, E.: The measurement of actual apparent power and actual reactive power from the instantaneous power signals in single-phase and three-phase systems. Electr. Power Syst. Res. (2014)Google Scholar
  11. 11.
    Shi, Y.: Calculation and Analysis of Reactive Power Under Power Electronic Load. SCUT(South China University of Technology) (2011)Google Scholar
  12. 12.
    Sarıbulut, L.: A simple power factor calculation for electrical power systems. Electr. Power Energy Syst. 06 (2011)Google Scholar
  13. 13.
    Li, Y.: Research on Phase Current Reconstruction Technology of Permanent Magnet Synchronous Motor. Harbin Institute of Technology (2014)Google Scholar

Copyright information

© Springer Nature Singapore Pte Ltd. 2020

Authors and Affiliations

  • Yicheng Wang
    • 1
    Email author
  • Zhiyong Huang
    • 1
  • Xiaolong Luo
    • 1
  • Yinguo Huang
    • 1
  1. 1.State Key Laboratory of Precision Measuring Technology and InstrumentsTianjin UniversityTianjinChina

Personalised recommendations