Advertisement

Design of Three-Phase AC-Voltage Regulator Energy-Saving System by SOPC

  • Tu YaEmail author
  • Jialu Du
  • Peng Cui
Conference paper
Part of the Lecture Notes in Electrical Engineering book series (LNEE, volume 517)

Abstract

Nios II is applied in three-phase AC-voltage regulator energy-saving system as the core microprocessor of FPGA system in this paper. A complete voltage regulating main topology circuit is designed. Only three groups of triggering signals are required to control the six thyristors’ conducting angles. A SOPC system is created by Qsys and Quartus II. The PID control algorithm is used to adjust the output voltage in real time according to the load change to save energy. The generation of high-precision triggering signals and PID control regulator functions are realized by Nios II, and simulated in MATLAB/Simulink. Experiments and in-field tests have shown the feasibility of the proposed scheme. The whole system’s analysis, synthesis, simulation and configuration are completed by Quartus II. Experiments show that the method is simple and reliable, and achieves a better energy-saving effect.

Keywords

Thyristor Three-phase AC-voltage regulator Energy-saving system SOPC 

References

  1. 1.
    Zhou, G.S., Zhang, Y., Shen, H., et al.: Design of SCR three-phase AC-voltage regulator based on STM32 MCU. Electron. Des. Eng. (2013)Google Scholar
  2. 2.
    Solet, D., Béchennec, J.L., Briday, M., Faucou, S., Pillement, S.: Hardware runtime verification of embedded software in SOPC. Ind. Embed. Syst. 1–6 (2016)Google Scholar
  3. 3.
    Zinoviev, G.S., Sidorov, A.V., Kharitonov, S.A.: Three-phase AC voltage regulator as part of an autonomous system. In: International Conference on Actual Problems of Electronics Instrument Engineering, pp. 762–765. IEEE (2015)Google Scholar
  4. 4.
    Zhou, G., Tu, Y., Zhao, S.: A three-phase AC-voltage regulator system. Telkomnika Indones. J. Electr. Eng. 12(5), 3501–3508 (2014)Google Scholar
  5. 5.
    Li, G., Liu, H., Gu, J., et al.: A novel three-phase series AC voltage regulator. In: Proceedings IPEMC 2000. The Third International Power Electronics and Motion Control Conference, 2000, vol. 3, pp. 1108–1110. IEEE (2002)Google Scholar
  6. 6.
    Sun, H., Wang, X., Lin, Q., Wang, X., Su, S.: The design of the DC servo motor controller based on fuzzy immune PID algorithm. In: Chinese Control Conference, pp. 4724–4729 (2017)Google Scholar
  7. 7.
    Jiang, M.C., Pan, P.E., Liu, T.C., et al.: A soft-switching modular three-phase AC voltage regulator. In: Telecommunications Energy Conference. IEEE (2016)Google Scholar
  8. 8.
    Rozhdenko, D.A., Udovichenko, A.V.: Digital control system with system of automatic control for three-phase two-zone thyristor AC voltage regulator. In: International Conference of Young Specialists on Micro/nanotechnologies and Electron Devices, pp. 374–376. IEEE (2013)Google Scholar
  9. 9.
    Orallo, C.M., Carugati, I., Funes, M., et al.: Thyristor gate control implementation on FPGA for particle accelerator facilities. In: Micro-Nanoelectronics, Technology and Applications, pp. 48–53. IEEE (2014)Google Scholar
  10. 10.
    Lati, A., Irki, Z., Sakhi, S., Nemra, A., Hamerlain, M.: Implementation of features detection and matching algorithms on FPGA using Nios II. In: International Conference on Modelling, pp. 55–60 (2017)Google Scholar

Copyright information

© Springer Nature Singapore Pte Ltd. 2020

Authors and Affiliations

  1. 1.School of Marine Electrical EngineeringDalian Maritime UniversityDalianChina
  2. 2.Dalian Neusoft University of InformationDalianChina
  3. 3.Liaoning Vocational College Light IndustryDalianChina

Personalised recommendations