Mechanism of Rectified Output Voltage Spike in Isolated Converter Under Wide Input Voltage

Conference paper
Part of the Lecture Notes in Electrical Engineering book series (LNEE, volume 482)

Abstract

There exists high rectified output voltage spike in isolated transformer’s secondary, especially for the high frequency link auxiliary inverters under wide input voltage. It will lead to increased voltage stress and loss of switching devices, impeding the improvement of system’s reliable operation and conversion efficiency. In order to solve the root causes of rectified output voltage spike, the mathematical model of rectifier output voltage is established. Based on the model, the mechanism of voltage spike is explored, deriving two main reasons: one is the wide input voltage, and the other is the resonance between the transformer leakage and the rectifier diode junction capacitor. Consequently, it is more pertinent to address the problem and improve the system’s reliability.

Keywords

Voltage spike Wide input voltage High frequency link Isolated converter 

References

  1. 1.
    Wang Y, Liu W, Yang Z et al (2014) Research on design evaluation of high-speed train auxiliary power supply system based on the AHP. Transportation electrification Asia-Pacific. Beijing, ChinaGoogle Scholar
  2. 2.
    Versèle C, Deblecker O, Lobry J (2010) Multiobjective optimal design of transformers for isolated switch mode power supplies. In: Power electronics electrical drives automation & motion international symposium on IEEE, pp 1687–1692Google Scholar
  3. 3.
    Martinez C, Lazaro A, Lucena C et al (2013) Improved modulator for losses reduction in auxiliary railway power supplies. In: Applied power electronics conference and exposition. California, USAGoogle Scholar
  4. 4.
    Espelage PM, Bose BK (1977) High-frequency link power conversion. IEEE Trans Indus Appl IA-13(5):387–394Google Scholar
  5. 5.
    Qian Z, Zhang J, Sheng K (2014) Status and development of power semiconductor devices and its applications. In: Proceedings of the CSEE 34(29):5149–5161. (In Chinese)Google Scholar
  6. 6.
    Pavlovsky M, De Haan SWH, Ferreira JA (2009) Reaching high power density in multikilowatt DC–DC converters with galvanic isolation. IEEE Trans Power Electron 24(3):603–612CrossRefGoogle Scholar
  7. 7.
    Maerz A, Bakran MM (2014) Designing a low weight low loss auxiliary converter for railway application. In: PCIM Europe 2014; international exhibition and conference for power electronics, intelligent motion, renewable energy and energy management; proceedings of VDEGoogle Scholar
  8. 8.
    Vinnikov D, Laugis J, Jalakas T (2007) Development of auxiliary power supplies for the 3.0 kV DC rolling stock. In: Industrial electronics, 2007. ISIE 2007. IEEE international symposium on IEEE, pp 359–364Google Scholar

Copyright information

© Springer Nature Singapore Pte Ltd. 2018

Authors and Affiliations

  1. 1.Naval University of Engineering, PLAQiaokou District, WuhanChina
  2. 2.System Engineering Institute, China State Shipbuilding CorporationHaidianChina