Accuracy Assessment of Continuous Glucose Monitoring Technology

  • J. Zhou
  • W. Jia
Chapter

Abstract

Good accuracy of continuous glucose monitoring (CGM) technology is a prerequisite for its clinical utility to guide decisions on treatment regimens. This chapter mainly explains how to evaluate the accuracy of CGM technology and its monitoring results. This chapter first introduces the accuracy assessment methods commonly used in clinical practice; then describes the accuracy assessment method for CGM technology, including consensus error grid analysis and continuous error grid analysis; and introduces the criteria of “optimal accuracy” for evaluating CGM data. This chapter also presents the factors affecting the accuracy of CGM technology and puts forward specific approaches for addressing these challenges.

Keywords

Continuous glucose monitoring Accuracy Consensus error grid analysis Continuous error grid analysis 

References

  1. 1.
    Clarke WL, Cox D, Gonder-Frederick LA, Carter W, Pohl SL. Evaluating clinical accuracy of systems for self-monitoring of blood glucose. Diabetes Care. 1987;10:622–8.CrossRefPubMedGoogle Scholar
  2. 2.
    Zhou J, Bao YQ, Ma XJ, Lu W, Hao YP, Zhou M, Mo YF, Hu C, Xiang KS, Jia WP. Accuracy assessment of continuous glucose monitoring by frequent venous blood collection in patients with type 2 diabetes mellitus. Chin J Diabetes Mellit. 2012;4:523–8.  https://doi.org/10.3760/cma.j.issn.1674-5809.2012.09.004.CrossRefGoogle Scholar
  3. 3.
    Parkes JL, Slatin SL, Pardo S, Ginsberg BH. A new consensus error grid to evaluate the clinical significance of inaccuracies in the measurement of blood glucose. Diabetes Care. 2000;23:1143–8.CrossRefPubMedGoogle Scholar
  4. 4.
    Kovatchev BP, Gonder-Frederick LA, Cox DJ, Clarke WL. Evaluating the accuracy of continuous glucose-monitoring sensors: continuous glucose-error grid analysis illustrated by TheraSense Freestyle Navigator data. Diabetes Care. 2004;27:1922–8.CrossRefPubMedGoogle Scholar
  5. 5.
    Zhou J, Lv X, Mu Y, Wang X, Li J, Zhang X, Wu J, Bao Y, Jia W. The accuracy and efficacy of real-time continuous glucose monitoring sensor in Chinese diabetes patients: a multicenter study. Diabetes Technol Ther. 2012;14:710–8.  https://doi.org/10.1089/dia.2012.0014.CrossRefPubMedPubMedCentralGoogle Scholar
  6. 6.
    Lu W, Zhou J, Ma XJ, Pan JM, Zhu W, Lu FD, Bao YQ, Jia WP. Assessment of the accuracy of continuous glucose monitoring and its correlated factor. West China Med J. 2011;26:811–4.Google Scholar

Copyright information

© Springer Nature Singapore Pte Ltd. and Shanghai Scientific and Technical Publishers 2018

Authors and Affiliations

  1. 1.Department of Endocrinology and Metabolism, Shanghai Clinical Center for Diabetes, Shanghai Diabetes InstituteShanghai Jiao Tong University, Affiliated Sixth People’s HospitalShanghaiChina

Personalised recommendations