Advertisement

Detection of Atrial Fibrillation Using 12-Lead ECG for Mobile Applications

  • Ricardo Jorge dos Santos Couceiro
  • Paulo Carvalho
  • Jorge Henriques
  • Rui Paiva
  • Manuel Jesus AntunesEmail author
Conference paper
Part of the IFMBE Proceedings book series (IFMBE, volume 64)

Abstract

Atrial Fibrillation (AF) is the most common arrhythmia and is associated with an increased risk of heart-related deaths and the development of conditions such as heart failure, dementia, and stroke. Affecting mostly elderly people, AF is associated with high comorbidity, increased mortality and is a major socio-economic impact in our society. Therefore, the detection of AF episodes in personalized health (p-Health) environments can be decisive in the prevention of major cardiac threats and in the reduction of health care costs. In this paper we present a new algorithm for detection of AF based on the assessment of the three main physiological characteristics of AF: (1) the irregularity of the heart rate; (2) the absence of the P-wave and (3) the presence of fibrillatory waves. Several features were extracted from the analysis of 12-lead electrocardiogram (ECG) signals, the best features were selected and a support vector machine classification model was adopted to discriminate AF and non-AF episodes. Our results show that the inclusion of features from the analysis of the recovered atrial activity was able to increase the performance of the algorithm: sensitivity of 88.5% and specificity of 92.9%. In the WELCOME project it is being designed a novel light vest with an integrated sensor system that collects several signals, including 12-lead ECG signals. The proposed algorithm is currently integrated in the WELCOME feature extraction module, which is responsible for receiving raw signals, extraction higher level features (e.g. occurrence of AF episodes) and provide them to the clinical decision process.

Notes

Acknowledgements

This work was supported by CISUC (Center for Informatics and Systems of University of Coimbra) and by EU projects Welcome (PTDC-EEI-PRO-2857-2012) and iCIS (CENTRO-07-ST24-FEDER-002003).

Conflict of Interest

The authors declare that they have no conflict of interest.

References

  1. 1.
    R. C. Davis, F. D. R. Hobbs, J. E. Kenkre, A. K. Roalfe, R. Iles, G. Y. H. Lip, et al., “Prevalence of atrial fibrillation in the general population and in high-risk groups: the ECHOES study,” EP Europace, vol. 14, pp. 1553–1559, 2012-11-01 00:00:00 2012.CrossRefGoogle Scholar
  2. 2.
    R. B. Schnabel, X. Yin, P. Gona, M. G. Larson, A. S. Beiser, D. D. McManus, et al., “50 year trends in atrial fibrillation prevalence, incidence, risk factors, and mortality in the Framingham Heart Study: a cohort study,” The Lancet, vol. 386, pp. 154–162.Google Scholar
  3. 3.
    G. B. Moody and R. G. Mark, “A new method for detecting atrial fibrillation using R-R intervals.,” in Computers in Cardiology, 1983, pp. 227–230.Google Scholar
  4. 4.
    S. Cerutti, L. T. Mainardi, A. Porta, and A. M. Bianchi, “Analysis of the dynamics of RR interval series for the detection of atrial fibrillation episodes,” in Computers in Cardiology 1997, 1997, pp. 77–80.Google Scholar
  5. 5.
    K. Tateno and L. Glass, “A method for detection of atrial fibrillation using RR intervals,” in Computers in Cardiology 2000, 2000, pp. 391–394.Google Scholar
  6. 6.
    L. Senhadji, F. Wang, A. Hernandez, and G. Carrault, “Wavelets extrema representation for QRS-T cancellation and P wave detection,” in Computers in Cardiology, 2002, 2002, pp. 37–40.Google Scholar
  7. 7.
    C. Sanchez, J. Millet, J. J. Rieta, F. Castells, J. Rodenas, R. Ruiz-Granell, et al., “Packet wavelet decomposition: An approach for atrial activity extraction,” in Computers in Cardiology, 2002, 2002, pp. 33–36.Google Scholar
  8. 8.
    S. Shkurovich, A. V. Sahakian, and S. Swiryn, “Detection of atrial activity from high-voltage leads of implantable ventricular defibrillators using a cancellation technique,” Biomedical Engineering, IEEE Transactions on, vol. 45, pp. 229–234, 1998.CrossRefGoogle Scholar
  9. 9.
    J. J. Rieta, F. Castells, C. Sanchez, V. Zarzoso, and J. Millet, “Atrial activity extraction for atrial fibrillation analysis using blind source separation,” Biomedical Engineering, IEEE Transactions on, vol. 51, pp. 1176–1186, 2004.CrossRefGoogle Scholar
  10. 10.
    R. Couceiro, P. Carvalho, J. Henriques, M. Antunes, M. Harris, and J. Habetha, “Detection of atrial fibrillation using model-based ECG analysis,” in ICPR 2008. 19th International Conference on Pattern Recognition, 2008, 2008, pp. 1–5.Google Scholar
  11. 11.
    Y. Sun, K. Chan, and S. Krishnan, “Characteristic wave detection in ECG signal using morphological transform,” BMC Cardiovascular Disorders, vol. 5, pp. 1–7, 2005.Google Scholar

Copyright information

© Springer Nature Singapore Pte Ltd. 2019

Authors and Affiliations

  • Ricardo Jorge dos Santos Couceiro
    • 1
  • Paulo Carvalho
    • 1
  • Jorge Henriques
    • 1
  • Rui Paiva
    • 1
  • Manuel Jesus Antunes
    • 2
    Email author
  1. 1.Department of Informatics Engineering, Science and Technology, Centre for Informatics and SystemsUniversity of CoimbraCoimbraPortugal
  2. 2.Centre of Cardio-Thoracic Surgery of the University Hospital of CoimbraCoimbraPortugal

Personalised recommendations