Abstract

Endoscopic ultrasound (EUS) is used to obtain ultrasound images from the gastrointestinal (GI) lumen by inserting an endoscope with a US transducer mounted at the tip. Recently, electronic scanning EUS has been developed, markedly improving the quality of conventional B-mode images. Moreover, EUS comes with various functions, including tissue harmonic imaging, Doppler function, elastography, and contrast harmonic echo using contrast agents. There are two types of EUS: the radial scanning (RS) and the curved linear array (CL). CL is now widely used for not only the pathological diagnosis through the collection of specimens but also various therapeutic applications. To perform both radial and curved array EUS, visualization of the target is necessary. Moreover, the EUS technique is operator dependent, and an operator must acquire a certain level of skill including interventional procedures. Nowadays, there are some training models which include living animal, ex vivo animal model, phantom, and computer-based simulator that are developed. With the expansion of indications, more complex skills will be required for EUS procedures, and appropriate training systems will play an increasingly vital role.

Keywords

Endoscopic ultrasound Endoscopic ultrasound-guided fine needle aspiration Interventional EUS Training model 

References

  1. 1.
    Maguchi H. The roles of endoscopic ultrasonography in the diagnosis of pancreatic tumors. J Hepato-Biliary-Pancreat Surg. 2004;11:1–3.CrossRefGoogle Scholar
  2. 2.
    Tierney WM, Adler DG, Chand B, et al. Echoendoscopes. Gastrointest Endosc. 2007;66:435–42.CrossRefPubMedGoogle Scholar
  3. 3.
    Tierney WM, Kochman ML, Scheiman JM. Computed tomography versus endoscopic ultrasonography for staging of pancreatic cancer. Ann Intern Med. 2005;142:590–1.CrossRefPubMedGoogle Scholar
  4. 4.
    Canto MI, Goggins M, Yeo CJ, et al. Screening for pancreatic neoplasia in high-risk individuals: an EUS-based approach. Clin Gastroenterol Hepatol. 2004;2:606–21.CrossRefPubMedGoogle Scholar
  5. 5.
    Liu CL, Lo CM, Chan JK, et al. EUS for detection of occult cholelithiasis in patients with idiopathic pancreatitis. Gastrointest Endosc. 2000;51:28–32.CrossRefPubMedGoogle Scholar
  6. 6.
    Koshita S, Fujita N, Noda Y, et al. Invasive carcinoma derived from “flat type” branch duct intraductal papillary mucinous neoplasms of the pancreas: impact of classification according to the height of mural nodule on endoscopic ultrasonography. J Hepatobiliary Pancreat Sci. 2015;22:301–9.CrossRefPubMedGoogle Scholar
  7. 7.
    Lee KH, Lee SJ, Lee JK, et al. Prediction of malignancy with endoscopic ultrasonography in patients with branch duct-type intraductal papillary mucinous neoplasm. Pancreas. 2014;43:1306–11.CrossRefPubMedGoogle Scholar
  8. 8.
    Li JH, He R, Li YM, et al. Endoscopic ultrasonography for tumor node staging and vascular invasion in pancreatic cancer: a meta-analysis. Dig Surg. 2014;31:297–305.CrossRefPubMedGoogle Scholar
  9. 9.
    Vilmann P, Jacobsen GK, Henriksen FW, et al. Endoscopic ultrasonography with guided fine needle aspiration biopsy in pancreas disease. Gastrointest Endosc. 1992;38:172–3.CrossRefPubMedGoogle Scholar
  10. 10.
    Wiersema MJ, Kochman ML, Cramer HM, et al. Endosonography-guided real-time fine-needle aspiration biopsy. Gastrointest Endosc. 1994;40:700–7.PubMedGoogle Scholar
  11. 11.
    Chang KJ, Katz KD, Durbin TE, et al. Endoscopic ultrasound-guided fine- needle aspiration. Gastrointest Endosc. 1994;40:694–9.PubMedGoogle Scholar
  12. 12.
    Chang KJ, Nguyen P, Erickson RA, et al. The clinical utility of endoscopic ultrasound-guided fine-needle aspiration in the diagnosis and staging of pancreas carcinoma. Gastrointest Endosc. 1997;45:387–93.CrossRefPubMedGoogle Scholar
  13. 13.
    Katanuma A, Maguchi H, Osanai M, et al. The difference in the capability of delineation between convex and radial arrayed echoendoscope for pancreas and biliary tract; case reports from the standpoint of both convex and radial arrayed echoendoscope. Dig Endosc. 2011;23:S2–8.CrossRefGoogle Scholar
  14. 14.
    Eloubeidi MA. Initial evaluation of the forward-viewing echoendoscope prototype for performing fine-needle aspiration, Trucut biopsy, and celiac plexus neurolysis. J Gastroenterol Hepatol. 2011;26:63–7.CrossRefPubMedGoogle Scholar
  15. 15.
    Kida M, Araki M, Miyazawa S, et al. Fine needle aspiration using forward-viewing endoscopic ultrasonography. Endoscopy. 2011;43:796–801.CrossRefPubMedGoogle Scholar
  16. 16.
    Kaneko M, Katanuma A, Maguchi H, et al. Prospective, randomized, comparative study of delineation capability of radial scanning and curved linear array endoscopic ultrasound for the pancreaticobiliary region. Endosc Int Open. 2014;2:E160–70.CrossRefPubMedPubMedCentralGoogle Scholar
  17. 17.
    Sakamoto H, Kitano M, Komaki T, et al. Prospective comparative study of the EUS guided 25-gauge FNA needle with the 19-gauge Trucut needle and 22-gauge FNA needle in patients with solid pancreatic masses. J Gastroenterol Hepatol. 2009;24:384–90.CrossRefPubMedGoogle Scholar
  18. 18.
    Siddiqui UD, Rossi F, Rosenthal LS, et al. EUS-guided FNA of solid pancreatic masses: a prospective, randomized trial comparing 22-gauge and 25-gauge needles. Gastrointest Endosc. 2009;70:1093–7.CrossRefPubMedGoogle Scholar
  19. 19.
    Grimm H, Binmoeller KF, Soehendra N. Endosonography-guided drainage of a pancreatic pseudocyst. Gastrointest Endosc. 1992;38:170–1.CrossRefPubMedGoogle Scholar
  20. 20.
    Akdamar MK, Eltoum I, Eloubeidi MA. Retroperitoneal paraganglioma: EUS appearance and risk associated with EUS-guided FNA. Gastrointest Endosc. 2004;60:1018–21.CrossRefPubMedGoogle Scholar
  21. 21.
    Sahai AV, Paquin SC, Gariépy G. A prospective comparison of endoscopic ultrasound-guided fine needle aspiration results obtained in the same lesion, with and without the needle stylet. Endoscopy. 2010;42:900–3.CrossRefPubMedGoogle Scholar
  22. 22.
    Wallace MB, Kennedy T, Durkalski V, et al. Randomized controlled trial of EUS-guided fine needle aspiration techniques for the detection of malignant lymphadenopathy. Gastrointest Endosc. 2001;54:441–7.CrossRefPubMedGoogle Scholar
  23. 23.
    Puri R, Vilmann P, Săftoiu A, et al. Randomized controlled trial of endoscopic ultrasound-guided fine-needle sampling with or without suction for better cytological diagnosis. Scand J Gastroenterol. 2009;44:499–504.CrossRefPubMedGoogle Scholar
  24. 24.
    Moller K, Papanikolaou IS, Toermer T, et al. EUS-guided FNA of solid pancreatic masses: high yield of 2 passes with combined histologic-cytologic analysis. Gastrointest Endosc. 2009;70:60–9.CrossRefPubMedGoogle Scholar
  25. 25.
    Iglesias-Garcia J, Dominguez-Munoz E, Lozano-Leon A, et al. Impact of endoscopic ultrasound-guided fine needle biopsy for diagnosis of pancreatic masses. World J Gastroenterol. 2007;13:289–93.CrossRefPubMedPubMedCentralGoogle Scholar
  26. 26.
    O’Toole D, Palazzo L, Arotçarena R, et al. Assessment of complications of EUS-guided fine-needle aspiration. Gastrointest Endosc. 2001;53:470–4.CrossRefPubMedGoogle Scholar
  27. 27.
    Adler DG, Jacobson BC, Davila RE, et al. ASGE guideline: complications of EUS. Gastrointest Endosc. 2005;61:8–12.CrossRefPubMedGoogle Scholar
  28. 28.
    Katanuma A, Maguchi H, Yane K, et al. Factors predictive of adverse events associated with endoscopic ultrasound-guided ne needle aspiration of pancreatic solid lesions. Dig Dis Sci. 2013;58:2093–9.CrossRefPubMedPubMedCentralGoogle Scholar
  29. 29.
    Shah JN, Fraker D, Guerry D, et al. Melanoma seeding of an EUS-guided fine needle track. Gastrointest Endosc. 2004;59:923–4.CrossRefPubMedGoogle Scholar
  30. 30.
    Doi S, Yasuda I, Iwashita T, et al. Needle tract implantation on the esophageal wall after EUS-guided FNA of metastatic mediastinal lymphadenopathy. Gastrointest Endosc. 2008;67:988–90.CrossRefPubMedGoogle Scholar
  31. 31.
    Katanuma A, Maguchi H, Hashigo S, et al. Tumor seeding after endoscopic ultrasound-guided fine-needle aspiration of cancer in the body of the pancreas. Endoscopy. 2012;44:E160–1.CrossRefPubMedGoogle Scholar
  32. 32.
    Bakker OJ, van Santvoort HC, van Brunschot S, et al. Endoscopic transgastric vs surgical necrosectomy for infected necrotizing pancreatitis: a randomized trial. JAMA. 2012;307:1053–61.CrossRefGoogle Scholar
  33. 33.
    Yasuda I, Nakashima M, Iwai T, et al. Japanese multicenter experience of endoscopic necrosectomy for infected walled-off pancreatic necrosis: the JENIPaN study. Endoscopy. 2013;45:627–34.CrossRefPubMedGoogle Scholar
  34. 34.
    Fujita N, Inui K, Kida M, et al. Standard imaging techniques in the pancreatobiliary region using radial scanning endoscopic ultrasonography. Dig Endosc. 2004;16:S118–33.CrossRefGoogle Scholar
  35. 35.
    Yamao K, Irisawa A, Inoue H, et al. Standard imaging techniques of endoscopic ultrasound-guided fine-needle aspiration using a curved linear array echoendoscope. Dig Endosc. 2007;19:S180–205.CrossRefGoogle Scholar
  36. 36.
    Eisen GM, Dominitz JA, Faigel DO, et al. Guidelines for credentialing and granting privileges for endoscopic ultrasound. Gastrointest Endosc. 2001;54:811–4.CrossRefPubMedGoogle Scholar
  37. 37.
    Wani S, Coté GA, Keswani R, et al. Learning curves for EUS by using cumulative sum analysis: implications for American Society for Gastrointestinal Endoscopy recommendations for training. Gastrointest Endosc. 2013;77:558–65.CrossRefPubMedGoogle Scholar
  38. 38.
    Mohamad A, Eloubeidi MA, Tamhane A. EUS-guided FNA of solid pancreatic masses: a learning curve with 300 consecutive procedures. Gastrointest Endosc. 2005;61:700–8.CrossRefGoogle Scholar
  39. 39.
    Wasan SM, Kapadia AS, Adler DG. EUS training and practice patterns among gastroenterologists completing training since 1993. Gastrointest Endosc. 2005;62:914–20.CrossRefPubMedGoogle Scholar
  40. 40.
    Barthet M. Endoscopic ultrasound teaching and learning. Minerva Med. 2007;98:247–51.PubMedGoogle Scholar
  41. 41.
    Neumann M, Mayer G, Ell C, et al. The Erlangen Endo-Trainer: life-like simulation for diagnostic and interventional endoscopic retrograde cholangiography. Endoscopy. 2000;32:906–10.CrossRefPubMedGoogle Scholar
  42. 42.
    Hochberger J, Maiss J, Magdeburg B, et al. Training simulators and education in gastrointestinal endoscopy: current status and perspectives in 2001. Endoscopy. 2001;33:541–9.CrossRefPubMedGoogle Scholar
  43. 43.
    Hochberger J, Neumann M, Hohenberger W, Hahn EG. Neuer Endoskopie-Trainer für die therapeutische flexible Endoskopie. Z Gastroenterol. 1997;35:722–3.Google Scholar
  44. 44.
    Wang MH, Dy F, Vu VK, et al. Structured endoscopic ultrasonography (EUS) training program improved knowledge and skills of trainees: results from the Asian EUS Group. Dig Endosc. 2015;27:687–91.CrossRefPubMedGoogle Scholar
  45. 45.
    Dhir V, Itoi T, Fockens P, et al. Novel ex vivo model for hands-on teaching of and training in EUS-guided biliary drainage: creation of “Mumbai EUS” stereolithography/3D printing bile duct prototype (with videos). Gastrointest Endosc. 2015;81:440–6.CrossRefPubMedGoogle Scholar
  46. 46.
    Bar-Meir S. A new endoscopic simulator. Endoscopy. 2000;32:898–900.CrossRefPubMedGoogle Scholar
  47. 47.
    Desilets DJ, Banerjee S, Barth BA, et al. Endoscopic simulators. Gastrointest Endosc. 2011;73:861–7.CrossRefPubMedGoogle Scholar

Copyright information

© Springer Japan KK, part of Springer Nature 2019

Authors and Affiliations

  • Akio Katanuma
    • 1
  • Hiroyuki Maguchi
    • 1
  • Kuniyuki Takahashi
    • 1
  • Kei Yane
    • 1
  • Toshifumi Kin
    • 1
  1. 1.Center for Gastroenterology, Teine-Keijinkai HospitalSapporoJapan

Personalised recommendations