Advertisement

Ein neues röntgenstrahlenfreies Zielverfahren für die distalen Verriegelungsbohrungen des unaufgebohrten Tibianagels (UTN)

  • C. Krettek
  • B. Könemann
  • O. Farouk
  • A. Kromm
  • H. Tscherne
Conference paper
Part of the Langenbecks Archiv für Chirurgie book series (DTGESCHIR, volume 1996)

A New Radiation-Free Aiming Technique for the Distal Locking Screws of the Unreamed Tibial Nail (UTN)

Summary

A mechanical aiming device for the placement of distal locking screws of the unreamed tibial nail (UTN) has been developed. At the level of the distal nail end, a roughly placed “contact hole” is drilled (diameter, 6.0 mm). An asymmetric spacer is inserted through this contact hole, placed directly onto the nail and connected with the aiming arm. By this re-adjustment, the direction and the plane of both distal transverse holes are defined and can be drilled. A medial spacer re-adjusts the aiming arm for the ap hole.

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

Literatur

  1. 1.
    Krettek C, Könemann B, Manns J, Schandelmaier P, Schmidt U, Tscherne H (1996) Analyse implantationsbedingter Nagelverformung und röntgenmorphometrische Untersuchungen als Grundlage für die Entwicklung eines Zielsystems für die distalen Verriegelungsbohrungen ohne Röntgenbild-verstärker für den unaufgebohrten Tibianagel (UTN). Unfallchirurg 99:671–678PubMedCrossRefGoogle Scholar
  2. 2.
    Krettek C, Manns J, Könemann B, Miclau T, Schandelmaier P, Tscherne H (1996) The deformation of small diameter solid tibial nails with unreamed intramedullary insertion. J Biomech (in press)Google Scholar
  3. 3.
    Krettek C, Könemann B, Nöschel F, Manns J, Blauth M, Tscherne H (1996) Entwicklung und klinische Anwendung eines Zielsystems für die distalen Verriegelungsbohrungen ohne Röntgenbildver-stärker für den unaufgebohrten Tibianagel (UTN). Unfallchirurg 99: (11) (im Druck)Google Scholar
  4. 4.
    Sanders R, Koval KJ, DiPasquale T, Schmelling G, Stenzler S (1993) Exposure of the orthopaedic surgeon to radiation. J Bone and Joint Surg [Am] 75-A: 326–330Google Scholar
  5. 5.
    Sugarman ID, Adam I, Bunker TD (1988) Radiation dosage during AO locking femoral nailing. Injury 19:336–338PubMedCrossRefGoogle Scholar