Minimum Inverter Capacity Design for HAPF

  • Chi-Seng LamEmail author
  • Man-Chung Wong
Chapter
  • 1.1k Downloads
Part of the SpringerBriefs in Electrical and Computer Engineering book series (BRIEFSELECTRIC)

Abstract

This chapter presents a minimum inverter capacity design for three-phase four-wire center-split hybrid active power filter (HAPF) in dynamic reactive power and current harmonics compensation. Based on HAPF equivalent circuit models in d-q-0 coordinate, the coupling part filtering characteristics of the HAPF without or with neutral inductor can be illustrated. According to the current quality data, the minimum dc-link voltage expressions for the HAPF without and with neutral inductor are deduced and compared. Conventionally, the coupling inductor and capacitor (LC) is usually tuned at a higher fifth or seventh order harmonic frequency to reduce its cost and size compared with the third order case. When triplen harmonic currents exist significantly, the HAPF with a small tuned neutral inductor can further reduce its minimum dc-link voltage requirement. Thus, the initial cost, switching loss and switching noise of the HAPF can be lowered. Representative simulation and experimental results of the three-phase four-wire HAPF with neutral inductor are presented to verify the filtering characteristics analysis and minimum dc-link voltage expressions, to show the effectiveness of reducing its inverter capacity, switching loss and switching noise in dynamic reactive power and current harmonics compensation compared with the conventional HAPF without neutral inductor.

Keywords

Coupling Neutral Inductor Current Harmonics d-q-0 Coordinate  Hybrid Active Power Filter Minimum DC-Link Voltage Reactive Power Switching Loss Switching Noise 

References

  1. 1.
    J.S. Subjek, J.S. Mcquilkin, Harmonics-causes, effects, measurements and analysis. IEEE Trans. Ind. Electron. 26(6), 1034–1042 (1990)Google Scholar
  2. 2.
    L.H.S. Duarte, M.F. Alves, The degradation of power capacitors under the influence of harmonics, in ProceedingsIEEE 10th International Conference on Harmonics and Quality of Power, vol. 1 (2002), pp. 334–339Google Scholar
  3. 3.
    T.Q. Tran, L.E. Conrad, B.K. Stallman, Electric shock and elevated EMF levels due to triplen harmonics. IEEE Trans. Power Del. 11(2), 1041–1049 (1996)CrossRefGoogle Scholar
  4. 4.
    H. Akagi, S. Srianthumrong, Y. Tamai, Comparisons in circuit configuration and filtering performance between hybrid and pure shunt active filters, in Conference Record IEEE-IAS Annual Meeting, vol. 2 (2003), pp. 1195–1202Google Scholar
  5. 5.
    S. Srianthumrong, H. Akagi, A medium-voltage transformerless AC/DC Power conversion system consisting of a diode rectifier and a shunt hybrid filter. IEEE Trans. Ind. Applicat. 39(3), 874–882 (2003)Google Scholar
  6. 6.
    W. Tangtheerajaroonwong, T. Hatada, K. Wada, H. Akagi, Design and performance of a transformerless shunt hybrid filter integrated into a three-phase diode rectifier. IEEE Trans. Power Electron. 22(5), 1882–1889 (2007)CrossRefGoogle Scholar
  7. 7.
    R. Inzunza, H. Akagi, A 6.6 kV transformerless shunt hybrid active filter for installation on a power distribution system. IEEE Trans. Power Electron. 20(4), 893–900 (2005)CrossRefGoogle Scholar
  8. 8.
    V.-F. Corasaniti, M.-B. Barbieri, P.-L. Arnera, M.-I. Valla, Hybrid power filter to enhance power quality in a medium voltage distribution. IEEE Trans. Ind. Electron. 56(8), 2885–2893 (2009)CrossRefGoogle Scholar
  9. 9.
    J.I. Rodriguez, A. Candela, L. Luna, R. Asiminoaei, R. Teodorescu, F. Blaabjerg, Current harmonics cancellation in three-phase four-wire systems by using a four-branch star filtering topology. IEEE Trans. Power Electron. 24(8), 1939–1950 (2009)CrossRefGoogle Scholar
  10. 10.
    C.-S. Lam, M.-C. Wong, Y.-D. Han, Voltage swell and overvoltage compensation with unidirectional power flow controlled dynamic voltage restorer. IEEE Trans. Power Del. 23(4), 2513–2521 (2008)CrossRefGoogle Scholar
  11. 11.
    S. Hiti, D. Boroyevich, C. Cuadros, Small-signal modeling and control of three-phase PWM conver1ters, in Conference Record of the Industry Applications Society Annual Meeting, vol. 2 (1994), pp. 1143–1150Google Scholar
  12. 12.
    R. Zhang High performance power converter systems for nonlinear and unbalanced load/source”, Ph.D. thesis, Virginia Polytechnic Institute and State University, 1998Google Scholar
  13. 13.
    M.-C. Wong, J. Tang, Y.-D. Han, Cylindrical coordinate control of three-dimensional PWM technique in three-phase four-wired trilevel inverter. IEEE Trans. Power Electron. 18(1), 208–220 (2003)CrossRefGoogle Scholar
  14. 14.
    IEEE Recommended Practice on Monitoring Electric Power Quality, 1995, IEEE Standard 1159:1995Google Scholar
  15. 15.
    Electromagnetic Compatibility (EMC), Part 3: Limits, Section 2: Limits for Harmonics Current Emissions (Equipment Input Current ≤ 16A Per Phase), IEC Standard 61000-3-2, 1997Google Scholar

Copyright information

© The Author(s) 2014

Authors and Affiliations

  1. 1.University of MacauMacaoPeople’s Republic of China

Personalised recommendations