Nonlinearity and Linearization of Hysteresis PWM Study and Analysis for HAPF

  • Chi-Seng LamEmail author
  • Man-Chung Wong
Chapter
Part of the SpringerBriefs in Electrical and Computer Engineering book series (BRIEFSELECTRIC)

Abstract

This chapter presents a hysteresis pulse width modulation (PWM) study for three-phase four-wire hybrid active power filter (HAPF). As the coupling inductor and capacitor (LC) impedance yields a nonlinear inverter current slope, this can affect the controllability of using the conventional hysteresis control method and generate unexpected trigger signals to the switching devices. This results in deteriorating the system operating performances. Based on the proposed modeling, the linearization of the hysteresis control for the HAPF is first studied, investigated, and compared with the linear active power filter (APF). Two limits are proposed in this work that divides the HAPF into nonlinear, quasi-linear, and linear operation regions. The design criteria of hysteresis band and sampling time can then be derived. Single-phase simulation and experimental results are given to verify the hysteresis control study of HAPF compared with APF. Finally, representative simulation and experimental results of a three-phase four-wire center-split HAPF for power quality compensation are presented to demonstrate the validity of the hysteresis linearization study.

Keywords

Active Power Filter Coupling LC Hybrid Active Power Filter Hysteresis PWM Linearization Nonlinear Inverter Current Slope  

References

  1. 1.
    B. Bose, Power electronics and variable frequency drives: technology and applications (IEEE Press, New York, 1997)Google Scholar
  2. 2.
    D.M. Brod, D.W. Novotny, Current control of VSI-PWM inverters. IEEE Trans. Ind. Appl. 21(3), 562–570 1985Google Scholar
  3. 3.
    B.K. Bose, An adaptive hysteresis-band current control technique of a voltage-fed PWM inverter for machine drive system. IEEE Trans. Ind. Appl. 37(5), 402–408 (1990)Google Scholar
  4. 4.
    B.-J. Kang, C.-M. Law, A robust hysteresis current-controlled PWM inverter for linear PMSM driven magnetic suspended positioning system. IEEE Trans. Ind. Appl. 48(5), 956–967 (2001)Google Scholar
  5. 5.
    L. Malesami, P. Mattavelli, P. Tomasin, High-performance hysteresis modulation technique for active filters. IEEE Trans. Power Electron. 12(5), 876–884 (1997)CrossRefGoogle Scholar
  6. 6.
    D. Casadei, G. Serra, A. Tani, L. Zarri, Theoretical and experimental analysis for the RMS current ripple minimization in induction motor drives controlled by SVM technique. IEEE Trans. Ind. Electron. 51(5), 1056–1065 (2004)CrossRefGoogle Scholar
  7. 7.
    D. Shen, P.W. Lehn, Fixed-frequency space-vector-modulation control for three-phase four-leg active power filters. IEEE Proc–Electr. Power Appl. 149(4), 268–274 2002Google Scholar
  8. 8.
    R. Zhang, V.H. Prasad, D. Boroyevich, F.C. Lee, Three-dimensional space vector modulation for four-leg voltage-source converters. IEEE Trans. Power Electron. 17(3), 314–326 (2002)CrossRefGoogle Scholar
  9. 9.
    C.J. Zhan, A. Arulampalam, N. Jenkins, Four-wire dynamic voltage restorer based on a three-dimensional voltage space vector PWM algorithm. IEEE Trans. Power Electron. 18(4), 1093–1102 (2003)CrossRefGoogle Scholar
  10. 10.
    S. Srianthumrong, H. Akagi, A medium-voltage transformerless AC/DC power conversion system consisting of a diode rectifier and a shunt hybrid filter. IEEE Trans. Ind. Appl. 39(3), 874–882 2003Google Scholar
  11. 11.
    W. Tangtheerajaroonwong, T. Hatada, K. Wada, H. Akagi, Design and performance of a transformerless shunt hybrid filter integrated into a three-phase diode rectifier. IEEE Trans. Power Electron. 22(5), 1882–1889 (2007)CrossRefGoogle Scholar
  12. 12.
    S. Rahmani, A. Hamadi, N. Mendalek, K. Al-Haddad, A new control technique for three-phase shunt hybrid power filter. IEEE Trans. Ind. Electron. 56(8), 2904–2915 (2009)CrossRefGoogle Scholar
  13. 13.
    IEEE recommended practices and requirements for harmonic control in electrical power systems, 1992, IEEE Standards 519–1992Google Scholar
  14. 14.
    Electromagnetic Compatibility (EMC), Part 3: Limits, Section 2: Limits for Harmonics Current Emissions (Equipment Input Current ≤ 16A Per Phase), IEC Standards 61000–3–2, 1997Google Scholar
  15. 15.
    IEEE Recommended Practice on Monitoring Electric Power Quality, 1995, IEEE Standards 1159:1995Google Scholar

Copyright information

© The Author(s) 2014

Authors and Affiliations

  1. 1.University of MacauMacaoPeople’s Republic of China

Personalised recommendations