Advertisement

Antiseptic Stewardship for Instrument Disinfectants

  • Günter Kampf
Chapter

Abstract

Instrument disinfectants can be based on different types of biocidal agents such as benzalkonium chloride, DDAC, glutaraldehyde, hydrogen peroxide, peracetic acid and sodium hypochlorite. A health benefit for patients can be expected for validated reprocessing of non-critical and semi-critical medical devices. A low adaptive response in combination with an inhibition of biofilm formation and removal of existing biofilm in the majority of species can be attributed to none of the biocidal agents. Overall, on surfaces of instruments where biofilm formation should be inhibited (e.g. flexible endoscopes), the use of peracetic acid seems to be the most appropriate option (low selection pressure, mainly inhibition of biofilm formation, mainly moderate removal of biofilm). Hydrogen peroxide and sodium hypochlorite have also a low selection pressure and can moderately remove biofilm, but they increased biofilm formation in more species. They seem to be appropriate on surfaces of instruments where enhancement of biofilm formation is of minor relevance. All three biocidal agents have so far not been associated with antibiotic cross-tolerance.  Benzalkonium chloride seems to be the least suitable biocidal agent taking into account the frequently observed strong and stable adaptive response, cross-tolerance to some other biological agents and selected antibiotics and the inconclusive effect on biofilm formation and removal.

References

  1. 1.
    Akinbobola AB, Sherry L, McKay WG, Ramage G, Williams C (2017) Tolerance of Pseudomonas aeruginosa in in-vitro biofilms to high-level peracetic acid disinfection. J Hosp Infect 97(2):162–168.  https://doi.org/10.1016/j.jhin.2017.06.024CrossRefPubMedGoogle Scholar
  2. 2.
    Dettenkofer M, Block C (2005) Hospital disinfection: efficacy and safety issues. Curr Opin Infect Dis 18(4):320–325CrossRefPubMedGoogle Scholar
  3. 3.
    Kovaleva J, Peters FT, van der Mei HC, Degener JE (2013) Transmission of infection by flexible gastrointestinal endoscopy and bronchoscopy. Clin Microbiol Rev 26(2):231–254.  https://doi.org/10.1128/cmr.00085-12CrossRefPubMedPubMedCentralGoogle Scholar
  4. 4.
    KRINKO am Robert Koch Institut (2012) Anforderungen an die Hygiene bei der Aufbereitung von Medizinprodukten. Bundesgesundheitsblatt 55(10):1244–1310CrossRefGoogle Scholar
  5. 5.
    Rutala WA, Weber DJ (2004) Disinfection and sterilization in health care facilities: what clinicians need to know. Clin Infect Dis: Off Publ Infect Dis Soc Am 39(5):702–709.  https://doi.org/10.1086/423182CrossRefGoogle Scholar
  6. 6.
    Rutala WA, Weber DJ (2016) Disinfection, sterilization, and antisepsis: an overview. Am J Infect Control 44(5 Suppl):e1–e6.  https://doi.org/10.1016/j.ajic.2015.10.038CrossRefPubMedGoogle Scholar
  7. 7.
    Silva e Souza AC, Pereira MS, Rodrigues MA (1998) [Disinfection of medical and surgical equipment: efficacy of chemical disinfectants and water and soap]. Revista latino-americana de enfermagem 6(3):95–105Google Scholar