Advertisement

Towards Integrating Imaging Techniques to Assess Manufacturing Features and In-Service Damage in Composite Components

  • I. Jiménez-Fortunato
  • D. J. Bull
  • J. M. Dulieu-Barton
  • O. T. Thomsen
Conference paper
Part of the Conference Proceedings of the Society for Experimental Mechanics Series book series (CPSEMS)

Abstract

Initial work on combining Thermoelastic Stress Analysis (TSA) and Digital Image Correlation (DIC) is presented with the purpose of exploring their used in assessing defects in composite materials. TSA is usually performed using photon detector cameras that are expensive, a further objective of the paper is to investigate the capabilities of low-cost bolometer IR cameras for TSA. A carbon fibre reinforced polymer (CFRP) sample with artificial ‘waviness’ was created, so that a crack was developed inside the material. Both TSA and lock-in DIC methods detected the damage inside the CFRP specimen. Using the bolometer for TSA has highlighted the need for longer data capture times and the deleterious effects of other features associated with image capture that are inherent in the bolometer system.

Keywords

Lock-in DIC TSA Composite materials Complex structures 

References

  1. 1.
    Rajic, N., Street, N.: A performance comparison between cooled and uncooled infrared detectors for thermoelastic stress analysis. Quant. Infrared Thermography J. 11(2), 207–221 (2014)CrossRefGoogle Scholar
  2. 2.
    Gade, R., Moeslund, T.B.: Thermal cameras and applications: a survey. Mach. Vis. Appl. 25, 245–262 (2014)CrossRefGoogle Scholar
  3. 3.
    Fruehmann, R.K., et al.: The use of a lock-in amplifier to apply digital image correlation to cyclically loaded components. Opt. Lasers Eng. 68, 149–159 (2015)CrossRefGoogle Scholar
  4. 4.
    Chen, D., et al.: Crack growth analysis in welded and non-welded T-joints based on lock-in digital image correlation and thermoelastic stress analysis. Int. J. Fatigue. 110, 172–185 (2018)CrossRefGoogle Scholar
  5. 5.
    Budzier, H., et al.: Fast microbolometer-based infrared camera system, presented at the 9th International Conference on Infrared Sensors & Systems, Nürnberg, Germany (2006)Google Scholar
  6. 6.
    Rajic, N., Rowlands, D.: Thermoelastic stress analysis with a compact low-cost microbolometer system. Quant. Infrared Thermography J. 10(2), 135–158 (2013)CrossRefGoogle Scholar

Copyright information

© The Society for Experimental Mechanics, Inc. 2019

Authors and Affiliations

  • I. Jiménez-Fortunato
    • 1
  • D. J. Bull
    • 1
  • J. M. Dulieu-Barton
    • 2
  • O. T. Thomsen
    • 1
  1. 1.Infrastructure Research Group, Faculty of Engineering and the EnvironmentUniversity of SouthamptonSouthamptonUK
  2. 2.Engineering Materials Research Group, Faculty of Engineering and the EnvironmentUniversity of SouthamptonSouthamptonUK

Personalised recommendations