Abstract

In October 1993, the team of the Thorax Center in Rotterdam transmitted three live cases to TCT in a 90-min session: the first one was a three-vessel disease treatment with three Palmaz-Schatz stents (not yet approved in the USA by the FDA) [1]; the second one was a recanalization of a CTO with a laser wire in a patient included in the TOTAL trial [2]; the third one was a drug-eluting balloon treatment (the Dispatch balloon) post balloon angioplasty [3].

References

  1. 1.
    Serruys PW, de Jaegere P, Kiemeneij F, Macaya C, Rutsch W, Heyndrickx G, Emanuelsson H, Marco J, Legrand V, Materne P, et al. A comparison of balloon-expandable-stent implantation with balloon angioplasty in patients with coronary artery disease. Benestent Study Group. N Engl J Med. 1994;331(8):489–95.CrossRefGoogle Scholar
  2. 2.
    Serruys PW, Hamburger JN, Koolen JJ, Fajadet J, Haude M, Klues H, Seabra-Gomes R, Corcos T, Hamm C, Pizzuli L, Meier B, Mathey D, Fleck E, Taeymans Y, Melkert R, Teunissen Y, Simon R. Total occlusion trial with angioplasty by using laser guidewire. The TOTAL trial. Eur Heart J. 2000;21(21):1797–805.CrossRefGoogle Scholar
  3. 3.
    Camenzind E, Kint PP, Di Mario C, Ligthart J, van der Giessen W, Boersma E, Serruys PW. Intracoronary heparin delivery in humans. Acute feasibility and long-term results. Circulation. 1995;92(9):2463–72.CrossRefGoogle Scholar
  4. 4.
    Camenzind E, Bakker WH, Reijs A, van Geijlswijk IM, Boersma E, Kutryk MJ, Krenning EP, Roelandt JR, Serruys PW. Site-specific intracoronary heparin delivery in humans after balloon angioplasty. A radioisotopic assessment of regional pharmacokinetics. Circulation. 1997;96(1):154–65.CrossRefGoogle Scholar
  5. 5.
    Tanabe K, Serruys PW, Degertekin M, Guagliumi G, Grube E, Chan C, Munzel T, Belardi J, Ruzyllo W, Bilodeau L, Kelbaek H, Ormiston J, Dawkins K, Roy L, Strauss BH, Disco C, Koglin J, Russell ME, Colombo A, TAXUS II Study Group. Chronic arterial responses to polymer-controlled paclitaxel-eluting stents: comparison with bare metal stents by serial intravascular ultrasound analyses: data from the randomized TAXUS-II trial. Circulation. 2004;109(2):196–200.CrossRefGoogle Scholar
  6. 6.
    Serruys PW, Degertekin M, Tanabe K, Russell ME, Guagliumi G, Webb J, Hamburger J, Rutsch W, Kaiser C, Whitbourn R, Camenzind E, Meredith I, Reeves F, Nienaber C, Benit E, Disco C, Koglin J, Colombo A, TAXUS II Study Group. Vascular responses at proximal and distal edges of paclitaxel-eluting stents: serial intravascular ultrasound analysis from the TAXUS II trial. Circulation. 2004;109(5):627–33.CrossRefGoogle Scholar
  7. 7.
    Tanabe K, Serruys PW, Degertekin M, Grube E, Guagliumi G, Urbaszek W, Bonnier J, Lablanche JM, Siminiak T, Nordrehaug J, Figulla H, Drzewiecki J, Banning A, Hauptmann K, Dudek D, Bruining N, Hamers R, Hoye A, Ligthart JM, Disco C, Koglin J, Russell ME, Colombo A, TAXUS II Study Group. Incomplete stent apposition after implantation of paclitaxel-eluting stents or bare metal stents: insights from the randomized TAXUS II trial. Circulation. 2005;111(7):900–5.CrossRefGoogle Scholar
  8. 8.
    Tanabe K, Serruys PW, Grube E, Smits PC, Selbach G, van der Giessen WJ, Staberock M, de Feyter P, Muller R, Regar E, Degertekin M, Ligthart JM, Disco C, Backx B, Russell ME. TAXUS III trial: in-stent restenosis treated with stent-based delivery of paclitaxel incorporated in a slow-release polymer formulation. Circulation. 2003;107(4):559–64.CrossRefGoogle Scholar
  9. 9.
    Scheller B, Hehrlein C, Bocksch W, Rutsch W, Haghi D, Dietz U, Bohm M, Speck U. Treatment of coronary in-stent restenosis with a paclitaxel-coated balloon catheter. N Engl J Med. 2006;355(20):2113–24.CrossRefGoogle Scholar
  10. 10.
    Katsanos K, Spiliopoulos S, Kitrou P, Krokidis M, Karnabatidis D. Risk of death following application of paclitaxel-coated balloons and stents in the femoropopliteal artery of the leg: a systematic review and meta-analysis of randomized controlled trials. J Am Heart Assoc. 2018;7(24):e011245.CrossRefGoogle Scholar
  11. 11.
    Lemos PA, Farooq V, Takimura CK, Gutierrez PS, Virmani R, Kolodgie F, Christians U, Kharlamov A, Doshi M, Sojitra P, van Beusekom HM, Serruys PW. Emerging technologies: polymer-free phospholipid encapsulated sirolimus nanocarriers for the controlled release of drug from a stent-plus-balloon or a stand-alone balloon catheter. EuroIntervention. 2013;9(1):148–56.CrossRefGoogle Scholar
  12. 12.
    Sabatine MS, Giugliano RP, Keech AC, Honarpour N, Wiviott SD, Murphy SA, Kuder JF, Wang H, Liu T, Wasserman SM, Sever PS, Pedersen TR. FOURIER Steering Committee and Investigators. Evolocumab and clinical outcomes in patients with cardiovascular disease. N Engl J Med. 2017;376(18):1713–22.CrossRefGoogle Scholar
  13. 13.
    Dotter CT, Buschmann RW, McKinney MK, Rosch J. Transluminal expandable nitinol coil stent grafting: preliminary report. Radiology. 1983;147(1):259–60.CrossRefGoogle Scholar
  14. 14.
    Dotter CT. Transluminally-placed coilspring endarterial tube grafts. Long-term patency in canine popliteal artery. Invest Radiol. 1969;4(5):329–32.CrossRefGoogle Scholar
  15. 15.
    Serruys PW, Garcia-Garcia HM, Onuma Y. From metallic cages to transient bioresorbable scaffolds: change in paradigm of coronary revascularization in the upcoming decade? Eur Heart J. 2012;33(1):16–25b.CrossRefGoogle Scholar