Abstract

Since first described in 1991, laparoscopy has become highly approved in renal surgery, particularly in laparoscopic radical nephrectomy (Clayman et al., N Engl J Med 324:1370–1371, 1991). In addition to the steep learning curve, one major point of criticism in laparoscopic partial nephrectomy is the prolonged warm ischemia time (Gill et al., J Urol 170:64–68, 2003). Hence, several techniques like early unclamping of the renal hilum were established to reduce ischemic injury to the kidney. Also the use of the enhanced instruments and improved vision in robotic surgery has an influence in reducing warm ischemia time. However, those above-mentioned laparoscopic techniques continued to require disruption of the entire arterial blood flow during tumor resection. An additional point of criticism is the missing haptic feedback. While tumor identification can also be challenging in more endophytic renal tumors in open surgery, the lack of a tactile senor system in laparoscopy and robotic surgery may lead to an even more difficult definition of the exact tumor boundaries.

References

  1. 1.
    Clayman RV, Kavoussi LR, Soper NJ, Dierks SM, Merety KS, Darcy MD, et al. Laparoscopic nephrectomy. N Engl J Med. 1991;324:1370–1.  https://doi.org/10.1056/NEJM199105093241917.CrossRefPubMedGoogle Scholar
  2. 2.
    Gill IS, Matin SF, Desai MM, Kaouk JH, Steinberg A, Mascha E, et al. Comparative analysis of laparoscopic versus open partial nephrectomy for renal tumors in 200 patients. J Urol. 2003;170:64–8.  https://doi.org/10.1097/01.ju.0000072272.02322.ff.CrossRefPubMedGoogle Scholar
  3. 3.
    Kaczmarek BF, Sukumar S, Kumar RK, Desa N, Jost K, Diaz M, et al. Comparison of robotic and laparoscopic ultrasound probes for robotic partial nephrectomy. J Endourol. 2013;27:1137–40.  https://doi.org/10.1089/end.2012.0528.CrossRefPubMedGoogle Scholar
  4. 4.
    Fox IJ, Brooker LG, Heseltine DW, Essex HE, Wood EH. A tricarbocyanine dye for continuous recording of dilution curves in whole blood independent of variations in blood oxygen saturation. Proc Staff Meet Mayo Clin. 1957;32:478–84.PubMedGoogle Scholar
  5. 5.
    Kogure K, David NJ, Yamanouchi U, Choromokos E. Infrared absorption angiography of the fundus circulation. Arch Ophthalmol. 1970;83:209–14.CrossRefPubMedGoogle Scholar
  6. 6.
    Tanaka E, Chen FY, Flaumenhaft R, Graham GJ, Laurence RG, Frangioni JV. Real-time assessment of cardiac perfusion, coronary angiography, and acute intravascular thrombi using dual-channel near-infrared fluorescence imaging. J Thorac Cardiovasc Surg. 2009;138:133–40.  https://doi.org/10.1016/j.jtcvs.2008.09.082.CrossRefPubMedPubMedCentralGoogle Scholar
  7. 7.
    van der Poel HG, Buckle T, Brouwer OR, Valdés Olmos RA, van Leeuwen FWB. Intraoperative laparoscopic fluorescence guidance to the sentinel lymph node in prostate cancer patients: clinical proof of concept of an integrated functional imaging approach using a multimodal tracer. Eur Urol. 2011;60:826–33.  https://doi.org/10.1016/j.eururo.2011.03.024.CrossRefPubMedGoogle Scholar
  8. 8.
    Obana A, Miki T, Hayashi K, Takeda M, Kawamura A, Mutoh T, et al. Survey of complications of indocyanine green angiography in Japan. Am J Ophthalmol. 1994;118:749–53.CrossRefPubMedGoogle Scholar
  9. 9.
    Ebert B, Riefke B, Sukowski U, Licha K. Cyanine dyes as contrast agents for near-infrared imaging in vivo: acute tolerance, pharmacokinetics, and fluorescence imaging. J Biomed Opt. 2011;16:066003.  https://doi.org/10.1117/1.3585678.CrossRefPubMedGoogle Scholar
  10. 10.
    Marano A, Priora F, Lenti LM, Ravazzoni F, Quarati R, Spinoglio G. Application of fluorescence in robotic general surgery: review of the literature and state of the art. World J Surg. 2013;37:2800–11.  https://doi.org/10.1007/s00268-013-2066-x.CrossRefPubMedGoogle Scholar
  11. 11.
    Tobis S, Knopf J, Silvers C, Yao J, Rashid H, Wu G, et al. Near infrared fluorescence imaging with robotic assisted laparoscopic partial nephrectomy: initial clinical experience for renal cortical tumors. J Uro. 2011;186:47–52.  https://doi.org/10.1016/j.juro.2011.02.2701.CrossRefGoogle Scholar
  12. 12.
    Manny TB, Krane LS, Hemal AK. Indocyanine green cannot predict malignancy in partial nephrectomy: histopathologic correlation with fluorescence pattern in 100 patients. J Endourol. 2013;27:918–21.  https://doi.org/10.1089/end.2012.0756.CrossRefPubMedPubMedCentralGoogle Scholar
  13. 13.
    Angell JE, Khemees TA, Abaza R. Optimization of near infrared fluorescence tumor localization during robotic partial nephrectomy. J Urol. 2013;190:1668–73.  https://doi.org/10.1016/j.juro.2013.04.072.CrossRefPubMedGoogle Scholar
  14. 14.
    Bjurlin MA, McClintock TR, Stifelman MD. Near-infrared fluorescence imaging with intraoperative administration of indocyanine green for robotic partial nephrectomy. Curr Urol Rep. 2015;16:495–7.  https://doi.org/10.1007/s11934-015-0495-9.CrossRefGoogle Scholar
  15. 15.
    Baumert H, Ballaro A, Shah N, Mansouri D, Zafar N, Molinié V, et al. Reducing warm ischaemia time during laparoscopic partial nephrectomy: a prospective comparison of two renal closure techniques. Eur Urol. 2007;52:1164–9.  https://doi.org/10.1016/j.eururo.2007.03.060.CrossRefPubMedGoogle Scholar
  16. 16.
    Novak R, Mulligan D, Abaza R. Laparoscopy and robotics. Urology. 2012:1–7.  https://doi.org/10.1016/j.urology.2012.01.065.
  17. 17.
    Gill IS, Eisenberg MS, Aron M, Berger A, Ukimura O, Patil MB, et al. “‘Zero ischemia’” partial nephrectomy: novel laparoscopic and robotic technique. Eur Urol. 2011;59:128–34.  https://doi.org/10.1016/j.eururo.2010.10.002.CrossRefPubMedGoogle Scholar
  18. 18.
    Harke N, Schoen G, Schiefelbein F, Heinrich E. Selective clamping under the usage of near-infrared fluorescence imaging with indocyanine green in robot-assisted partial nephrectomy: a single-surgeon matched-pair study. World J Urol. 2014;32:1259–65.  https://doi.org/10.1007/s00345-013-1202-4.CrossRefPubMedGoogle Scholar
  19. 19.
    Komninos C, Shin TY, Tuliao P, Han WK, Chung BH, Choi YD, et al. Renal function is the same regardless of clamp technique 6 months after robot-assisted partial nephrectomy: analysis of off-clamp, selective arterial clamp and main artery clamp with minimum of 1 year follow-up. BJU Int. 2015;115:921–8.  https://doi.org/10.1111/bju.12975.CrossRefPubMedGoogle Scholar

Copyright information

© Springer International Publishing AG 2018

Authors and Affiliations

  1. 1.Department for Urology, Pediatric Urology and Urologic OncologyProstate Center Northwest, Center for Robotic Medicine Germany, St. Antonius-HospitalGronauGermany

Personalised recommendations