Monitoring During Expiration

  • Jean-Michel Arnal
Chapter

Abstract

Expiration is usually passive in patients mechanically ventilated. Expiration monitoring relies mainly on the flow curve which depends on the expiratory time constant. Hence monitoring of expiratory flow informs about the patient’s respiratory mechanics. If the expiratory flow does not reach baseline at the end of expiratory time, dynamic hyperinflation is suspected. An end-expiratory occlusion maneuver is used to measure intrinsic PEEP.

Supplementary material

Video 3.1

Flow limitation (AVI 458531 kb)

Video 3.2

Secretions (AVI 400925 kb)

Video 3.3

End-expiratory occlusion in VC (AVI 175117 kb)

Video 3.4

End-expiratory occlusion in PC (AVI 105999 kb)

Video 3.5

AutoPEEP without dynamic hyperinflation (AVI 324888 kb)

Suggested Readings

  1. Bigatello LM, Davignon KR, et al. Respiratory mechanics and ventilator waveforms in the patient with acute lung injury. Respir Care. 2005;50:235–45.PubMedGoogle Scholar
  2. Blanch L, Bernabé F, et al. Measurement of air trapping, intrinsic positive end-expiratory pressure, and dynamic hyperinflation in mechanically ventilated patients. Respir Care. 2005;50:110–23.PubMedGoogle Scholar
  3. Brochard L. Intrinsic (or auto-) PEEP during controlled mechanical ventilation. Intensive Care Med. 2002a;28:1376–8.CrossRefPubMedGoogle Scholar
  4. Brochard L. Intrinsic (or auto-) positive end-expiratory pressure during spontaneous or assisted ventilation. Intensive Care Med. 2002b;28:1552–4.CrossRefPubMedGoogle Scholar
  5. Brunner JX, Laubsher T, et al. Simple method to measure total expiratory time constant based on passive expiratory flow-volume curve. Crit Care Med. 1995;23:1117–22.CrossRefPubMedGoogle Scholar
  6. Dhand R. Ventilator graphics and respiratory mechanics in the patient with obstructive lung disease. Respir Care. 2005;50:246–61.PubMedGoogle Scholar
  7. Georgopoulos D, Prinianakis G, et al. Bedside waveforms interpretation as a tool to identify patient-ventilator asynchronies. Intensive Care Med. 2006;32:34–47.CrossRefPubMedGoogle Scholar
  8. Iotti G, Braschi A. Measurement of respiratory mechanics during mechanical ventilation. Rhäzüns, Switzerland: Hamilton Medical Scientific Library; 1999.Google Scholar
  9. Kondili E, Alexopoulou C, et al. Pattern of lung emptying and expiratory resistance in mechanically ventilated patients with chronic obstructive pulmonary disease. Intensive Care Med. 2004;30:1311–8.CrossRefPubMedGoogle Scholar
  10. Lourens MS, Van Den Berg B, et al. Expiratory time constants in mechanically ventilated patients with and without COPD. Intensive Care Med. 2000;26:1612–8.CrossRefPubMedGoogle Scholar
  11. Maltais F, Reissmann H, et al. Comparison of static and dynamic measurements of intrinsic PEEP in mechanically ventilated patients. Am J Respir Crit Care Med. 1994;150:1318–24.CrossRefPubMedGoogle Scholar
  12. Marini JJ. Dynamic hyperinflation and auto-positive end-expiratory pressure: lessons learned over 30 years. Am J Respir Crit Care Med. 2011;184:756–62.CrossRefPubMedGoogle Scholar
  13. Mauri T, Bellani G, et al. Regional distribution of air trapping in chronic obstructive pulmonary disease. Am J Respir Crit Care Med. 2013;188:1466–7.CrossRefPubMedGoogle Scholar
  14. Ranieri VM, Grasso S, et al. Auto-positive end-expiratory pressure and dynamic hyperinflation. Clin Chest Med. 1996;17:379–94.CrossRefPubMedGoogle Scholar
  15. Volta CA, Marangoni E, et al. Respiratory mechanics by least squares fitting in mechanically ventilated patients: application on flow-limited COPD patients. Intensive Care Med. 2002;28:48–52.CrossRefPubMedGoogle Scholar

Copyright information

© Springer International Publishing AG 2018

Authors and Affiliations

  • Jean-Michel Arnal
    • 1
    • 2
  1. 1.Service de Réanimation PolyvalenteHopital Sainte MusseToulonFrance
  2. 2.Applied Research and New TechnologyHamilton Medical AGBonaduzSwitzerland

Personalised recommendations