Advertisement

High Quality of Calibration Accuracy for Smart Building Energy-Efficiency Opportunities

  • G. Mustafaraj
Conference paper

Abstract

A well-calibrated model is crucial to accurately represent a building’s energy profile. This chapter deals with a building where an underfloor heating system supplied by a geothermal water-to-water heat pump and natural ventilation are the main systems used to maintain comfort conditions. Existing methodologies to establish calibration accuracy are mainly based on whole-building energy consumption comparisons. This research considers whole-building energy consumption with a breakdown of end-use energy consumption. The objective of this work is to develop a two-level calibration methodology which starts with calibration and then continues with the necessary actions for improving building energy efficiency. Finally, the model was simulated to estimate the potential of energy-efficiency improvements. The results of the analysis show that electricity consumption savings and heat released from the heat pump can vary between 20 and 27 % on a monthly basis.

Keywords

Calibration Smart buildings Energy efficiency Natural ventilation Underfloor heating Water-to-water heat pump Natural ventilation 

References

  1. 1.
    Perez-Lombard L, Ortiz J, Pout C (2008) A review on buildings energy consumption information. Energy Build 40:394–398CrossRefGoogle Scholar
  2. 2.
    Directive 2010/31/EU of the European Parliament and of the Council. On the energy performance of buildings. Articles 14–16, 19 May 2010Google Scholar
  3. 3.
    Raftery P, Keane M, Costa A (2011) Calibrating whole building energy models: detailed case study using hourly measured data. Energy Build 43:3666–3679CrossRefGoogle Scholar
  4. 4.
    Bertagnolio S (2012) Evidence based model calibration for efficient building energy services. Ph.D. Thesis, University of LiègeGoogle Scholar
  5. 5.
    Menezes AC, Cripps A, Bouchlaghem D, Buswell R (2012) Predicted vs. actual energy performance of non-domestic buildings: using post-occupancy evaluation data to reduce the performance gap. Appl Energy 97:355–364CrossRefGoogle Scholar
  6. 6.
    Liu G, Liu M (2012) A rapid calibration procedure and case study for simplified simulation models of commonly used HVAC systems. Build Environ 46:409–420CrossRefGoogle Scholar
  7. 7.
    CarbonBuzz-website. http://www.carbonbuzz.org
  8. 8.
    Hamilton I, Steadman P, Bruhns H (2011) CarbonBuzz—energy data audit, UCL Energy Institute, July 2011Google Scholar
  9. 9.
    EnergyPlus Version 8.2 (2014) U.S. Department of Energy, Energy Efficiency and Renewable Energy, Office of Building Technologies. http://www.energyplus.gov
  10. 10.
    ASHRAE guideline 14 (2002) Measurement of energy and demand savings. American Society of Heating, Refrigerating, and Air-Conditioning Engineers, Atlanta, GAGoogle Scholar
  11. 11.
    Mustafaraj G, Marini D, Costa A, Keane M (2014) Model calibration for building energy efficiency simulation. Appl Energy 130:72–85CrossRefGoogle Scholar
  12. 12.
    Azar E, Menassa C (2012) A comprehensive analysis of the impact of occupancy parameters in energy simulation of office buildings. Energy Build 55:841–853CrossRefGoogle Scholar
  13. 13.
    Morris M (1991) Factorial sampling plans for preliminary computational experiments. Technometrics 33:161–174CrossRefGoogle Scholar
  14. 14.
    De Wit S, Augenbroe G (2002) Analysis of uncertainty in building design evaluations and its implications. Energy Build 34:951–958CrossRefGoogle Scholar
  15. 15.
    Heiselberg P, Brohus PH (2007) Application of sensitivity analysis in design of sustainable buildings. Proceedings of the international conference on sustainable development in building and environment, Chongqing, ChinaGoogle Scholar
  16. 16.
  17. 17.
    CIBSE Guide (2006) A environmental design. The Chartered Institution of Building Services Engineers, LondonGoogle Scholar
  18. 18.
    ASHRAE Fundamentals Handbook (2005) Atlanta: American Society of Heating, Refrigerating and Air-Conditioning Engineers, IncGoogle Scholar
  19. 19.
    ASHRAE Standard 62.2 (2013) Ventilation and acceptable indoor air quality in low-rise residential buildingsGoogle Scholar

Copyright information

© Springer International Publishing Switzerland 2017

<SimplePara><Emphasis Type="Bold">Open Access</Emphasis> This chapter is licensed under the terms of the Creative Commons Attribution-NonCommercial 2.5 International License (http://creativecommons.org/licenses/by-nc/2.5/), which permits any noncommercial use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license and indicate if changes were made. </SimplePara> <SimplePara>The images or other third party material in this chapter are included in the chapter's Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the chapter's Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder.</SimplePara>

Authors and Affiliations

  1. 1.International Energy Research Centre IERCTyndall Institute, University College of CorkCorkIreland

Personalised recommendations