Advertisement

Issues and Solutions for Compartments with Exposed Structural Mass Timber Elements

  • David BarberEmail author
  • Robert Dixon
  • Susan Deeny
  • Pascal Steenbakkers
Conference paper
  • 28 Downloads

Abstract

High-rise mass timber buildings with CLT and glulam are being planned and constructed within the globally. As timber buildings are constructed taller, architects and building owners are requesting more timber be exposed. High-rise buildings are required to have fire resistance ratings for the structural elements that can withstand the design fire in the highly unlikely event of a fully developed fire. Addressing how exposed timber and in particular CLT, influences a fully developed fire through to fire extinguishment is a current fire safety issue. The fire heat release rate and fire duration will be increased due to the added combustible fuel available from the exposed timber, when compared to a compartment without any exposed timber, once all the fixtures and furnishings have been consumed. Existing fire test data shows that large areas of exposed timber has a significant impact on heat release rate, but limited areas of exposed timber can be accommodated within a fire safe design. To design a compartment with exposed timber requires an understanding of the susceptibility of the CLT to char fall off and the expected fire duration due to the area and location of the exposed timber.

Keywords

Mass timber Cross laminated timber Compartment fires High-rise buildings Performance-based design 

References

  1. 1.
  2. 2.
  3. 3.
  4. 4.
    Su J, LaFrance P, Hoehler M, Bundy M (2018) Fire safety challenges of tall wood buildings – phase 2: task 2 & 3 cross laminated timber compartment fire tests. Fire Protection Research Foundation, Report No. FPRF-2018-01Google Scholar
  5. 5.
    Frangi A, et al (2008) Fire behaviour of cross-laminated solid timber panels. Institute of Structural Engineering, ETH Zurich, Zurich, SwitzerlandGoogle Scholar
  6. 6.
    Klippel M (2014) Fire safety of bonded structural timber elements. ETH Zurich, Institute of Structural Engineering, thesis number 359Google Scholar
  7. 7.
    Crielaard R (2015) Self-extinguishment of cross-laminated timber, thesis, Delft University of Technology, NetherlandsGoogle Scholar
  8. 8.
    Barber D, Crielaard R, Li X (2016) Towards fire safe design of exposed timber in tall timber buildings. In: Proceedings of the world conference of timber engineering, 22–25 August 2016, ViennaGoogle Scholar
  9. 9.
    Brandon D, Dagenais C (2018) Fire safety challenges of tall wood buildings – phase 2: task 5 - experimental study of delamination of cross laminated timber (CLT) in fire. Fire Protection Research Foundation, report no. FPRF-2018–05Google Scholar
  10. 10.
    Karacabeyli E, Douglas B (2013) CLT handbook, US edition FPInnovations SP529-EGoogle Scholar
  11. 11.
    ANSI/APA (2018) PRG-320 standard for performance-rated cross-laminated timberGoogle Scholar
  12. 12.
    American Society for Testing and Materials (2016) ASTM E119: standard test methods for fire tests of building construction and materialsGoogle Scholar
  13. 13.
    Frangi A, Fontana M (2005) Fire performance of timber structures under natural fire conditions. In: Fire safety science – proceedings of the eighth international symposium, pp 279–290Google Scholar
  14. 14.
    Hakkarainen T (2002) Post-flashover fires in light and heavy timber construction compartments. J Fire Sci 20:133–175.  https://doi.org/10.1177/0734904102020002074CrossRefGoogle Scholar
  15. 15.
    McGregor C (2013) Contribution of cross laminated timber panels to room fires, thesis. Carleton University, Ottawa, CanadaGoogle Scholar
  16. 16.
    Medina A (2014) Fire resistance of partially protected CLT rooms, thesis. Carleton University, Ottawa, CanadaGoogle Scholar
  17. 17.
    Hadden R, Bartlett A, Hidalgo J, Santamaria S, Wiesner F, Bisby L, Deeny S, Lane B (2017) Effects of exposed engineered timber on compartment fire dynamics. In: Proceedings of the 12th international association of fire safety science symposium, Lund, 10 June to 16 2017Google Scholar
  18. 18.
    Hox K (2015) Branntest av massivtre SP fire research, report A15101 (in Norwegian, translated by Arup)Google Scholar
  19. 19.
    Emberley R, Gorska C, Bolanosa A, Lucherinia A, Solartea A, Soriguera D, Gutierrez M, Humphreys K, Hidalgoa J, Maluka C, Law A, Torero J (2017) Description of small and large-scale cross laminated timber fire tests. Fire Saf J 91:327–335Google Scholar
  20. 20.
    Zelinka S, Hasburgh L, Bourne K, Tucholski D, Ouellette J (2018) Compartment fire testing of a two-story mass timber building. General technical report FPL–GTR–247, May 2018Google Scholar
  21. 21.
    Just A, Brandon D, Nele Mäger K, Pukk R, Sjöström J, Kahl F (2018) CLT compartment fire test. In: Proceedings of world conference on timber engineering, 20–22 August 2018, SeoulGoogle Scholar
  22. 22.
    Su J, Leroux P, Lafrance P, Berzins R, Gratton K, Gibbs E, Weinfurter M (2018) Fire testing of rooms with exposed wood surfaces in encapsulated mass timber construction. National Research Council, Canada report no. A1-012710.1Google Scholar
  23. 23.
    Buchanan A (2001) Structural design for fire safety. Wiley, HobokenGoogle Scholar

Copyright information

© Springer Nature Switzerland AG 2020

Authors and Affiliations

  • David Barber
    • 1
    Email author
  • Robert Dixon
    • 2
  • Susan Deeny
    • 3
  • Pascal Steenbakkers
    • 4
  1. 1.ArupWashington, DCUSA
  2. 2.ArupDocklandsAustralia
  3. 3.Arup, Scotstoun HouseEdinburghUK
  4. 4.ArupAmsterdamThe Netherlands

Personalised recommendations