Advertisement

Pseudohypoglycemia

  • Fadi Aboona
  • Sulmaz Zahedi
  • S. Sethu K. Reddy
Chapter

Abstract

Pseudohypoglycemia is defined as a patient having apparent hypoglycemia. We describe these syndromes as pseudohypoglycemia type 1 (PHG-1) and pseudohypoglycemia type 2 (PHG-2), respectively. PHG-1 usually refers to when the individual may be displaying symptoms suggestive of hypoglycemia, but the plasma sugar levels are greater than 70 mg/dL. Patients with diabetes and chronic hyperglycemia can present with primarily adrenergic symptoms of hypoglycemia at relatively higher serum glucose levels during periods of aggressive glucose control, sometimes labeled as relative hypoglycemia. However, we can extend the definition to also include a variety of patients presenting with sugar values below 70 mg/dL but no symptoms of hypoglycemia. This scenario could be labeled as pseudohypoglycemia type 2 (PHG-2), with minimal symptoms. For PHG-2, one must always rule out technical/methodological errors first. Increased glucose utilization or extraction peripherally via erythrocytes or leucocytes must also be considered. A careful history and understanding glucose measurement and glucose metabolism will greatly help the clinician manage these phenomena.

Keywords

Pseudohypoglycemia Relative hypoglycemia Falsely low glucose values 

References

  1. 1.
    Macleod JJR. The control of carbohydrate metabolism. Bull Johns Hopkins Hosp. 1934;54:79–139.Google Scholar
  2. 2.
    Cannon WB, Mclver MA, Bliss SW. Studies on the conditions of activity in endocrine glands. XIII. A sympathetic and adrenal mechanism for mobilizing sugar in hypoglycemia. Am J Physiol. 1924;69:46–66.CrossRefGoogle Scholar
  3. 3.
    Himwich HE. A review of hypoglycemia, its physiology and pathology, symptomatology, and treatment. Am J Dig Dis. 1944;11(1):1.CrossRefGoogle Scholar
  4. 4.
    Dalal BI, Brigden ML. Factitious biochemical measurements resulting from hematologic conditions. Am J Clin Pathol. 2009;131(2):195–204.CrossRefGoogle Scholar
  5. 5.
    Theofilogiannakos EK, Giannakoulas G, Ziakas A, Karvounis HI, Styliadis IH. Pseudohypoglycemia in a patient with the Eisenmenger syndrome. Ann Intern Med. 2010;152(6):407.CrossRefGoogle Scholar
  6. 6.
    Wang EY, Patrick L, Connor DM. Blind obedience and an unnecessary workup for hypoglycemia: a teachable moment. JAMA Intern Med. 2018;178(2):279–80.CrossRefGoogle Scholar
  7. 7.
    Klonoff DC, Alexander Fleming G, Muchmore DB, Frier BM. Hypoglycemia evaluation and reporting in diabetes: importance for the development of new therapies. Diabetes Metab Res Rev. 2017;33(5):e2883.CrossRefGoogle Scholar
  8. 8.
    Shaefer C, Hinnen D, Sadler C. Hypoglycemia and diabetes: increased need for awareness. Curr Med Res Opin. 2016;32(9):1479–86.CrossRefGoogle Scholar
  9. 9.
    Rushakoff RJ, Lewis SB. Case of pseudohypoglycemia. Diabetes Care. 2001;24(12):2157–8.CrossRefGoogle Scholar
  10. 10.
    Khoury M, Yousuf F, Martin V, Cohen R. Pseudohypoglycemia: a cause for unreliable finger-stick glucose measurements. Endocr Pract. 2008;14(3):337–9.CrossRefGoogle Scholar
  11. 11.
    Fanelli CG, Lucidi P, Bolli GB, Porcellati F. Hypoglycemia. In: Diabetes complications, comorbidities, and related disorders. Cham: Springer; 2018. p. 617–54.CrossRefGoogle Scholar
  12. 12.
    Spanakis EK, Cryer PE, Davis SN. Hypoglycemia during therapy of diabetes. In: Feingold KR, Anawalt B, Boyce A, et al., editors. Endotext [Internet]. South Dartmouth (MA): MDText.com, Inc; 2018.Google Scholar
  13. 13.
    Fabrykant M. Pseudohypoglycemic reactions in insulin-treated diabetics: etiology, laboratory aids and therapy. J Am Geriatr Soc. 1964;12(3):221–38.CrossRefGoogle Scholar
  14. 14.
    Tonyushkina K, Nichols JH. Glucose meters: a review of technical challenges to obtaining accurate results. J Diabetes Sci Technol. 2009;3(4):971–80. Published 2009.CrossRefGoogle Scholar
  15. 15.
    Kadhem S, Ebrahem R, Ahmed B, Mortada R. Unreliable fingerstick glucose measurement in systemic sclerosis. AACE Clin Case Rep. 2016;2(4):e367–9.CrossRefGoogle Scholar
  16. 16.
    Crevel E, Ardigo S, Perrenoud L, Vischer UM. Acrocyanosis as a cause of pseudohypoglycemia. J Am Geriatr Soc. 2009;57(8):1519–20.CrossRefGoogle Scholar
  17. 17.
    Kagawa D, Ando S, Ueda T, Nakamura T, Domae N, Uchino H. A case of chronic myelogenous leukemia with pseudohypoglycemia: correlation between leukocyte counts and blood glucose levels. [Rinsho ketsueki] Jpn J Clin Hematol. 1987;28(10):1790–4.Google Scholar
  18. 18.
    Wenk RE, Yoho S, Bengzon A. Pseudohypoglycemia with monoclonal immunoglobulin M. Arch Pathol Lab Med. 2005;129(4):454–5.PubMedGoogle Scholar
  19. 19.
    Ginsberg BH. Factors affecting blood glucose monitoring: sources of errors in measurement. J Diabetes Sci Technol. 2009;3(4):903–13. Published 2009.CrossRefGoogle Scholar
  20. 20.
    Liang Y, Rice MJ. Assessing glucose meter accuracy: the details matter! Anesthesiology. 2018;128(5):1044–5.CrossRefGoogle Scholar
  21. 21.
    Thabit H, Hovorka R. Bridging technology and clinical practice: innovating inpatient hyperglycemia management in non-critical care settings. Diabet Med. 2018;35(4):460–71.CrossRefGoogle Scholar
  22. 22.
    Li M, Zhou J, Bao YQ, Lu W, Jia WP. Prediction of nocturnal hypoglycemia with bedtime glucose level during continuous subcutaneous insulin infusion in type 2 diabetics. Zhonghua Yi Xue Za Zhi. 2010;90:2962–6.PubMedGoogle Scholar
  23. 23.
    Ma XJ, Zhou J. Using continuous glucose monitoring for patients with hypoglycemia. In: Continuous glucose monitoring. Singapore: Springer; 2018. p. 121–8.CrossRefGoogle Scholar
  24. 24.
    Peyser TA, Nakamura K, Price D, Bohnett LC, Hirsch IB, Balo A. Hypoglycemic accuracy and improved low glucose alerts of the latest Dexcom G4 Platinum continuous glucose monitoring system. Diabetes Technol Ther. 2015;17:548–54.CrossRefGoogle Scholar
  25. 25.
    Wentholt IM, Maran A, Masurel N, Heine RJ, Hoekstra JB, DeVries JH. Nocturnal hypoglycemia in Type 1 diabetic patients, assessed with continuous glucose monitoring: frequency, duration, and associations. Diabet Med. 2007;24:527–32.CrossRefGoogle Scholar

Copyright information

© Springer Nature Switzerland AG 2019

Authors and Affiliations

  • Fadi Aboona
    • 1
  • Sulmaz Zahedi
    • 1
  • S. Sethu K. Reddy
    • 1
  1. 1.Discipline of Medicine, Central Michigan University College of MedicineMt. PleasantUSA

Personalised recommendations