Advertisement

Invasive Medical Device for Cardiovascular Surgery

  • Alexandra EneEmail author
  • Carmen Mihai
Conference paper
Part of the Advances in Intelligent Systems and Computing book series (AISC, volume 957)

Abstract

The identification of the biological requirements of the most complicated mechanism as the human body, correlated with the possibilities of the current technique, has enabled the successful achievement of an advanced material destined to be used as invasive medical device in cardiovascular surgery. In order to accomplish this type of medical device there is an increasing need for synthetic yarns characterized through: adequate ration resistance/weight, elasticity, flexibility, biocompatibility, chemical inertia etc. To design the fabrics destined for the vascular prostheses, there have been taken into account the minimal requirements for the bio functional characteristics, imposed by clinical usage field, from which there resulted the following: the product geometry imposes the use of the tubular or branched structure; impermeability imposes main parameters of fabric designing (achievement of a structure for which there are used untwisted yarns, the densities of the two systems and the product mass, etc.

The level of biomedical and bio functional performances demonstrate that the advanced product developed is suitable to be used in surgical intervention for replacement portion of vascular system with different geometry, in case of thrombosis, occlusion, aneurysm.

Keywords

Biomaterials Blood flow Cardiovascular surgery 

Notes

Acknowledgment

This scientific paper is funded by the Ministry of Research and Innovation within Program 1 - Development of the national RD system, Subprogram 1.2 - Institutional Performance - RDI excellence funding projects, Contract no. 6PFE/2018.

References

  1. 1.
    Izaguirre, J.A., Chaturvedi, R., Huang, C., Cickovski, T., Thomas, G., Forgac, G., Alber, M., Hentschel, G., Newman, S.A., Glazier, J.A.: COMPU-CELL, a multi-model framework for simulation of morphogenesis. Bioinformatics 20(7), 1129–1137 (2004)CrossRefGoogle Scholar
  2. 2.
    Murea, C.M., Hentschel, G.: Finite element methods for investigating the moving boundary problem in biological development. Prog. Nonlinear Differ. Eqn. Appl. 64, 357–371 (2005)MathSciNetzbMATHGoogle Scholar
  3. 3.
    Leier, A., Marquez-Lago, T.: Correction factors for boundary diffusion in reaction-diffusion master equations. J. Chem. Phys. 135(13), 1–10 (2011)CrossRefGoogle Scholar

Copyright information

© Springer Nature Switzerland AG 2020

Authors and Affiliations

  1. 1.The National Research and Development Institute for Textiles and LeatherBucharestRomania

Personalised recommendations