Advertisement

Design Features of Surface Plasmon Resonance Sensors

  • Leiva Casemiro OliveiraEmail author
  • Antonio Marcus Nogueira Lima
  • Carsten Thirstrup
  • Helmut Franz Neff
Chapter
Part of the Springer Series in Surface Sciences book series (SSSUR, volume 70)

Abstract

The two sensing modes under consideration, the angular (AIM) and spectral (WIM) modes, exhibit advantages and disadvantages in terms of technical complexity, data processing and operating conditions. Schematics of the AIM and WIM optical set-up are shown in Fig. 3.1a, b, respectively. Each setup comprises a flat dove type prism chip. The design route allows the construction of compact instruments and avoids implementation of a bulky optical prism. The optical function of SPR prism chip is similar to a waveguide. In the AIM, incident radiation is a spectrally narrow band, while the angle range is wide and the resonance angle is recorded. In the WIM, the incident radiation is spectrally broadband, the incident angle range is narrow, comprising a collimated light beam, and a spectrometer tracks the resonance wavelength. A third-less popular-hybrid sensor configuration is the Intensity Mode (IM), as shown in Fig. 3.1c, where a collimated beam at a fixed (resonance) angle and wavelength is employed. The temperature coefficient of the refractive index of water at ambient T, with \(-1.2\times 10^{-4}\) RIU/\({^\circ }\)C, is quite high and exceeds those of the optical components, typically used in the optics design. Hence, it should be recalled that SPR sensors are particularly sensitive to temperature fluctuations. They are also sensitive to mechanical vibrations or thermal distortions in the optical path, down to the micrometer or even sub-micrometer levels. A rigid mechanical design is therefore beneficial. Surface conditions, preparation and functionalization, as well as long term temporal stability and signal drift effects are further important issues, since recordings may last for several hours.

References

  1. 1.
    Thirstrup, C., Zong, W., Borre, M., Neff, H., Pedersen, H.C., Holzhueter, G.: Diffractive optical coupling element for surface plasmon resonance sensors. Sens.S Actuators B: Chem. 100, 298–308 (2004)CrossRefGoogle Scholar
  2. 2.
    Oliveira. L.C., Moreira, C.S., Thirstrup, C., Melcher, E.U.K., Lima, A.M.N., Neff, F.H.: A surface plasmon resonance biochip that operates both in the angular and wavelength interrogation modes. IEEE TIM 62, 1223–1232 (2013)Google Scholar
  3. 3.
    Willets, K.A., Van Duyne, R.P.: Localized surface plasmon resonance spectroscopy and sensing. Ann. Rev. Phys. Chem. 58, 267–297 (2007)Google Scholar
  4. 4.
    Liao, W.S., Chen, X., Yang, T., Castellana, E.T., Chen, J., Cremer, P.S., Transmission localized surface plasmon resonance platforms: Benchtop chemistry for the rapid prototyping of label-free biosensors. Biointerphases 4, 80–85 (2009)CrossRefGoogle Scholar
  5. 5.
    Estevez, M.-C., Otte, M.A., Sepulveda, B., Lechuga, L.M.: Trends and challenges of refractometric nanoplasmonic biosensors: A review. Anal. Chim. Acta 806, 55–73 (2014)Google Scholar
  6. 6.
    Kim, D.K., Kerman, K., Saito, M., Sathuluri, R.R., Endo, T., Yamamura, S., Kwon, Y.S., Tamiya, E.: Label-free DNA biosensor based on localized surface plasmon resonance coupled with interferometry. Anal. Chem. 79, 1855–1864 (2007)CrossRefGoogle Scholar
  7. 7.
    Sherry, L.J., Jin, R.C., Mirkin, C.A., Mirkin, G.C., Scharz, G.C., Van Duyne, R.P.: Localized surface plasmon resonance spectroscopy of single silver triangular nanoprisms. Nano Lett. 6(9), 2060–2065 (2006)ADSCrossRefGoogle Scholar
  8. 8.
    Henry, A.I., Bingham, J.M., Ringe, E., Marks, L.D., Schatz, G.C., Van Duyne, R.P.: Correlated structure and optical property studies of plasmonic nanoparticles. J. Phys. Chem. C 115, 9291–9305 (2011)CrossRefGoogle Scholar
  9. 9.
    Hutter, E., Fendler, J.H.: Exploitation of localized surface plasmon resonance. Adv. Mater. 16, 1685–1706 (2004)CrossRefGoogle Scholar
  10. 10.
    Kerker, M.: The Scattering of Light and Other Electromagnetic Radiation. Academic Press, New York (1969)Google Scholar
  11. 11.
    Zalyubovskiy, S.J., Bogdanova, M., Deinega, A., Lozovik, Y., Pris, A.D., Hyup An, K., Hall, W.P., Potyrailo, R.A.: Theoretical limit of localized surface plasmon resonance sensitivity to local refractive index change and its comparison to conventional surface plasmon resonance sensor. J. Opt. Soc. Am. A 29, 904–1001 (2012)Google Scholar
  12. 12.
    Rao, C.N.R., Kulkarni, G.U., Thomasa, P.J., Edwards, P.P.: Metal nano-particles and their assemblies. Chem. Soc. Rev. 29, 27–35 (2000)Google Scholar

Copyright information

© Springer Nature Switzerland AG 2019

Authors and Affiliations

  • Leiva Casemiro Oliveira
    • 1
    Email author
  • Antonio Marcus Nogueira Lima
    • 2
  • Carsten Thirstrup
    • 3
  • Helmut Franz Neff
    • 2
  1. 1.Department of Computer Science (DC)Federal University of the Semi-Arid Region (UFERSA)MossoróBrazil
  2. 2.Department of Electrical Engineering (DEE)Federal University of Campina Grande (UFCG)Campina GrandeBrazil
  3. 3.Danish National Metrology InstituteKongens LyngbyDenmark

Personalised recommendations