Advertisement

Non-anatomical Monopolar Uncemented Radial Head Arthroplasty: Surgical Technique and Expected Outcomes

  • Davide Blonna
  • Marco Lamalfa
Chapter

Abstract

Non-anatomical monopolar uncemented radial head arthroplasty is one of the most commonly performed radial head arthroplasties and is one of the first radial head replacements with a well-documented long-term follow-up. These designs behave as a spacer and are based on the concept that a real anatomical replacement of the radial head is not achievable due to the extreme anatomical variability. With a proper learning curve and precise surgical technique, good medium- to long-term follow-up should be expected. A common complication seems to be the radiolucency around the stem that, however, does not correlate with clinical symptoms.

Keywords

Radial head replacement Elbow instability Monopolar radial head Overstuffing Surgical technique Radial head fracture 

References

  1. 1.
    Grewal R, MacDermid JC, Faber KJ, Drosdowech DS, King GJ. Comminuted radial head fractures treated with a modular metallic radial head arthroplasty. Study of outcomes. J Bone Joint Surg Am. 2006;88(10):2192–200.PubMedGoogle Scholar
  2. 2.
    Harrington IJ, Sekyi-Otu A, Barrington TW, Evans DC, Tuli V. The functional outcome with metallic radial head implants in the treatment of unstable elbow fractures: a long-term review. J Trauma. 2001;50(1):46–52.CrossRefPubMedGoogle Scholar
  3. 3.
    Marsh JP, Grewal R, Faber KJ, Drosdowech DS, Athwal GS, King GJ. Radial head fractures treated with modular metallic radial head replacement: outcomes at a mean follow-up of eight years. J Bone Joint Surg Am. 2016;98(7):527–35.CrossRefPubMedGoogle Scholar
  4. 4.
    Moghaddam A, Raven TF, Dremel E, Studier-Fischer S, Grutzner PA, Biglari B. Outcome of radial head arthroplasty in comminuted radial head fractures: short and midterm results. Trauma Mon. 2016;21(1):e20201.CrossRefPubMedPubMedCentralGoogle Scholar
  5. 5.
    Chen AC, Chou YC, Weng CJ, Cheng CY. Long-term outcomes of modular metal prosthesis replacement in patients with irreparable radial head fractures. J Orthop Surg Res. 2018;13(1):134.CrossRefPubMedPubMedCentralGoogle Scholar
  6. 6.
    Rodriguez-Quintana D, Comulada DB, Rodriguez-Quintana N, Lopez-Gonzalez F. Radial head ingrowth anatomic implant versus smooth stem monoblock implant in acute terrible triad injury: a prospective comparative study. J Orthop Trauma. 2017;31(9):503–9.CrossRefPubMedGoogle Scholar

Copyright information

© Springer Nature Switzerland AG 2020

Authors and Affiliations

  • Davide Blonna
    • 1
  • Marco Lamalfa
    • 1
  1. 1.Ospedale Mauriziano di TorinoTorinoItaly

Personalised recommendations