Advertisement

A High-Performance and High-Reliability RAIS5 Storage Architecture with Adaptive Stripe

  • Linjun Mei
  • Dan Feng
  • Lingfang Zeng
  • Jianxi Chen
  • Jingning Liu
Conference paper
Part of the Lecture Notes in Computer Science book series (LNCS, volume 11334)

Abstract

In the era of big data, the traditional RAID storage system has been incapable of meeting the requirements of performance and reliability for the large amount of data storage and computing. In view of the situation, Solid State Disks (SSDs), which can provide better performance than Hard Disk Drives (HDDs), are widely used to construct storage arrays in enterprise environments. Today many studies on Redundant Array of Independent SSDs (RAIS) storage systems concentrate more on improving write performance, and show less attention on the reconstruction performance of RAIS storage systems. In this paper, we proposed RAIS5AS, a novel RAIS5 storage architecture with adaptive stripe for improving the performance and reliability of RAIS5. RAIS5AS distinguishes between logical stripe and physical stripe. Logical stripe is a traditional RAID stripe. Physical stripe consists of the blocks (in a logical stripe) which have been written data. When handling write requests, RAIS5AS uses physical stripe as the basic processing unit to choose which blocks are read to compute the new parity block. When recovering data, RAIS5AS skips the unused failed blocks. In addition, RAIS5AS simplifies the synchronization process of RAIS5 storage system. We have implemented the proposed scheme and carried out a series of experiments. RAIS5AS on average improves write performance and reconstruction performance of the basic RAIS5 by up to 7.92% and 95.65% respectively, and those of JOR by 9.16% and 14.57% respectively.

Keywords

Physical stripe Performance Reconstruction time RAIS5 

Notes

Acknowledgements

This work was supported by the National High Technology Research and Development Program (863 Program) No. 2015AA016701, No. 2015AA015301; NSFC No. 61772222, No. U1705261, No. 61472153, No. 61402189, No. 61303046; State Key Laboratory of Computer Architecture, No. CARCH201505; Wuhan Applied Basic Research Project (No. 2015010101010004).

References

  1. 1.
    Mei, L., Feng, D., Zeng, L., Chen, J., Liu, J.: A write-through cache method to improve small write performance of SSD-based RAID. In: Proceedings of the 12th International Conference on Networking, Architecture, and Storage, Shenzhen, China, pp. 1–6, August 2017Google Scholar
  2. 2.
    Kim, T., Lee, S., Park, J., Kim, J.: Efficient lifetime management of SSD-based RAIDs using dedup-assisted partial stripe writes. In: Proceedings of the 5th Non Volatile Memory Systems and Applications Symposium, Daegu, South Korea, pp. 1–6, August 2016Google Scholar
  3. 3.
    Wan, J., Wu, W., Zhan, L., Yang, Q., Qu, X., Xie, C.: DEFT-cache: a cost effective and highly reliable SSD cache for RAID storage. In: Proceedings of the 2017 IEEE International Parallel and Distributed Processing Symposium, Orlando, FL, pp. 102–111, May 2017Google Scholar
  4. 4.
    Lee, E., Oh, Y., Lee, D.: SSD caching to overcome small write problem of disk-based RAID in enterprise environments. In: Proceedings of the 30th Annual ACM Symposium on Applied Computing Software Verification and Testing Track, Salamanca, Spain, pp. 2047–2053, April 2015Google Scholar
  5. 5.
    Pan, Y., Li, Y., Xu, Y., Shen, B.: DCS: diagonal coding scheme for enhancing the endurance of SSD-based RAID arrays. IEEE Trans. Comput.-Aided Des. Integr. Circ. Syst. 35(8), 1372–1385 (2016)CrossRefGoogle Scholar
  6. 6.
    Wu, S., Mao, B., Chen, X., Jiang, H.: LDM: log disk mirroring with improved performance and reliability for SSD-based disk arrays. ACM Trans. Storage (TOS) 12(4), 22 (2016)Google Scholar
  7. 7.
    Tian, L., et al.: PRO: a popularity-based multi-threaded reconstruction optimization for RAID-structured storage systems. In: Proceedings of the 2007 USENIX Conference on File and Storage Technologies, San Jose, CA, pp. 277–290, February 2007Google Scholar
  8. 8.
    Sivathanu, M., Prabhakaran, V., Arpaci-Dusseau, A., Arpaci-Dusseau, R.: Improving storage system availability with D-GRAID. ACM Trans. Storage (TOS) 1(2), 133–170 (2005)CrossRefGoogle Scholar
  9. 9.
    Wu, S., Feng, D., Jiang, H., Mao, B., Zeng, L., Chen, J.: JOR: a journal-guided reconstruction optimization for RAID-structured storage systems. In: Proceedings of the 15th IEEE International Conference on Parallel and Distributed Systems, Shenzhen, China, , pp. 609–616, December 2009Google Scholar
  10. 10.
    Jin, C., Feng, D., Jiang, H., Tian, L.: RAID6L: a log-assisted RAID6 storage architecture with improved write performance. In: Proceedings of the IEEE 27th Symposium on Mass Storage Systems and Technologies, Denver, Colorado, pp. 1-6, May 2011Google Scholar
  11. 11.
    UMass Trace Repository: Two I/O traces from OLTP applications running at two large financial institutions (2007). http://traces.cs.umass.edu/index.php/Storage/Storage
  12. 12.
    Microsoft Enterprise Traces (2009). http://iotta.snia.org/traces/list/BlockIO
  13. 13.
    Agrawal, N., Prabhakaran, V., Wobber, T., Davis, J., Manasse, M., Panigrahy, R.: Design tradeoffs for SSD performance. In: Proceedings of the 2008 USENIX Annual Technical Conference, Boston, MA, pp. 57–70, June 2008Google Scholar
  14. 14.
    Wu, S., Jiang, H., Feng, D., Tian, L., Mao, B.: WorkOut: I/O workload outsourcing for boosting RAID reconstruction performance. In: Proceedings of the USENIX Conference on File and Storage Technologies, San Francisco, CA, pp. 239–252, February 2009Google Scholar
  15. 15.
    Holland, M., Gibson, G., Siewiorek, D.: Architectures and algorithms for on-line failure recovery in redundant disk arrays. J. Distrib. Parallel Databases 2(3), 295–335 (1994)CrossRefGoogle Scholar
  16. 16.
    Holland, M., Gibson, G., Siewiorek, D.: Fast, on-line failure recovery in redundant disk arrays. In: Proceedings of the 23 Annual International Symposium on Fault-Tolerant Computing, Toulouse, France, pp. 422–431, June 1993Google Scholar
  17. 17.
    Lee, J., Lui, J.: Automatic recovery from disk failure in continuous-media servers. IEEE Trans. Parallel Distrib. Syst. 13(5), 499–515 (2002)CrossRefGoogle Scholar
  18. 18.
    Mao, B., et al.: a hybrid parity-based disk array for enhanced perfromance and reliability. ACM Trans. Storage 8(1), 1C20 (2012)CrossRefGoogle Scholar
  19. 19.
    Zeng, L., Feng, D., Chen, J., Wei, Q.: HRAID6ML: a hybrid RAID6 storage architecture with mirrored logging. In: Proceedings of the IEEE 28th Symposium on Mass Storage Systems and Technologies, Pacific Grove, CA, pp. 1–6, April 2012Google Scholar

Copyright information

© Springer Nature Switzerland AG 2018

Authors and Affiliations

  • Linjun Mei
    • 1
  • Dan Feng
    • 1
  • Lingfang Zeng
    • 1
  • Jianxi Chen
    • 1
  • Jingning Liu
    • 1
  1. 1.School of Computer Science and Technology, Wuhan National Laboratory for Optoelectronics, Key Laboratory of Information Storage System Ministry of Education of ChinaHuazhong University of Science and TechnologyWuhanChina

Personalised recommendations