Cardiac CT Platforms: State of the Art

  • Bernhard SchmidtEmail author
  • Katharine Grant
  • Thomas G. Flohr
  • Thomas Allmendinger
Chapter
Part of the Contemporary Medical Imaging book series (CMI)

Abstract

Shorter scan times and the desire for higher resolution were the driving forces behind the development of spiral scanning in 1990 and the first multi-detector row computed tomography (CT) systems in 1998. With the introduction of ECG-gated scanning on four-slice CT scanners in 1999, the first step toward cardiac imaging with multi-detector row computed tomography (MDCT) had been made.

Available since 2004, 64-slice CT systems are currently considered prerequisite for routine cardiac imaging in clinical scenarios, and with its introduction, the task of imaging coronary arteries and calcium scoring replaced EBCT (electron beam CT) completely. 64-slice CT systems allowed for comprehensive diagnosis of morphology and cardiac function within one integrated CT examination, including high-resolution imaging of the coronary arteries. Improved temporal resolution (< 200 ms) was enabled by faster gantry rotation times down to 0.33 s and leading to an increased clinical robustness of ECG-gated scanning techniques at higher heart rates (Leber et al. J Am Coll Cardiol 46:147–154, 2005; Raff et al. J Am Coll Cardiol 46:552, 2005). ECG-gated 64-slice CT also started being used for rapid triage of patients with acute chest pain in the emergency room and for diagnosis of pulmonary embolism, aortic dissection or aneurysm, or significant coronary artery disease in one scan.

Keywords

Cardiac CT platforms 64-slice CT systems ECG-gated scanning Dual-source CT (DSCT) system Multi-detector row CT setup ECG-synchronized CT volume imaging of the heart 

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. 1.
    Kalender WA, Seissler W, Klotz E, Vock P. Spiral volumetric CT with single-breath-hold technique, continuous transport, and continuous scanner rotation. Radiology. 1990;176(1):181–3.PubMedGoogle Scholar
  2. 2.
    Achenbach S, Ulzheimer S, Baum U, et al. Noninvasive coronary angiography by retrospectively ECG-gated multi-slice spiral CT. Circulation. 2000;102:2823–8.PubMedGoogle Scholar
  3. 3.
    Becker C, Knez A, Ohnesorge B, Schöpf U, Reiser M. Imaging of non calcified coronary plaques using helical CT with retrospective EKG gating. AJR. 2000;175:423–4.PubMedGoogle Scholar
  4. 4.
    Knez A, Becker C, Leber A, Ohnesorge B, Reiser M, Haberl R. Non-invasive assessment of coronary artery stenoses with multidetector helical computed tomography. Circulation. 2000;101:e221–2.PubMedGoogle Scholar
  5. 5.
    Ohnesorge B, Flohr T, Becker C, Kopp A, Schoepf U, Baum U, Knez A, Klingenbeck Regn K, Reiser M. Cardiac imaging by means of electro- cardiographically gated multisection spiral CT – initial experience. Radiology. 2000;217:564–71.PubMedGoogle Scholar
  6. 6.
    Nieman K, Oudkerk M, Rensing B, van Oijen P, Munne A, van Geuns R, de Feyter P. Coronary angiography with multi-slice computed tomography. Lancet. 2001;357:599–603.PubMedGoogle Scholar
  7. 7.
    Hoffmann MHK, Shi H, Schmitz BL, Schmid FT, Lieberknecht M, Schulze R, Ludwig B, Kroschel U, Jahnke N, Haerer W, Brambs H-J, Aschoff AJ. Noninvasive coronary angiography with multislice computed tomography. JAMA. 2005;293:2471–8.PubMedGoogle Scholar
  8. 8.
    Leschka S, Wildermuth S, Boehm T, Desbiolles L, Husmann L, Plass A, Koepfli P, Schepis T, Marincek B, Kaufmann PA, Alkadhi H. Noninvasive coronary angiography with 64-section CT: effect of average heart rate and heart rate variability on image quality. Radiology. 2006;241(2):378–85.PubMedGoogle Scholar
  9. 9.
    Leber AW, Knez A, Ziegler F, Becker A, Nikolaou K, Paul S, Wintersperger B, Reiser MF, Becker CR, Steinbeck G, Boekstegers P. Quantification of obstructive and nonobstructive coronary lesions by 64-slice computed tomography – a comparative study with quantitative coronary angiography and intravascular ultrasound. J Am Coll Cardiol. 2005;46(1):147–54.PubMedGoogle Scholar
  10. 10.
    Raff GL, Gallagher MJ, O’Neill WW, Goldstein JA. Diagnostic accuracy of non-invasive coronary angiography using 64-slice spiral computed tomography. J Am Coll Cardiol. 2005;46(3):552.PubMedGoogle Scholar
  11. 11.
    Salem R, Remy-Jardin M, Delhaye D, Khalil C, Teisseire A, Delannoy-Deken V, Duhamel A, Remy J. Integrated cardio-thoracic imaging with ECG-gated 64-slice multidetector-row CT: initial findings in 133 patients. Eur Radiol. 2006;16(9):1973–81.PubMedGoogle Scholar
  12. 12.
    Bruzzi JF, Rémy-Jardin M, Delhaye D, Teisseire A, Khalil C, Rémy J. When, why, and how to examine the heart during thoracic CT: part 1, basic principles. AJR Am J Roentgenol. 2006;186(2):324–32.PubMedGoogle Scholar
  13. 13.
    Bruzzi JF, Rémy-Jardin M, Delhaye D, Teisseire A, Khalil C, Rémy J. When, why, and how to examine the heart during thoracic CT: part 2, clinical applications. AJR Am J Roentgenol. 2006;186(2):333–41.PubMedGoogle Scholar
  14. 14.
    Delhaye D, Remy-Jardin M, Salem R, Teisseire A, Khalil C, Delannoy-Deken V, Duhamel A, Remy J. Coronary imaging quality in routine ECG-gated multidetector CT examinations of the entire thorax: preliminary experience with a 64-slice CT system in 133 patients. Eur Radiol. 2007;17(4):902–10.PubMedGoogle Scholar
  15. 15.
    Flohr T, Ohnesorge B. Heart rate adaptive optimization of spatial and temporal resolution for electrocardiogram-gated multislice spiral CT of the heart. J Comput Assist Tomogr. 2001;25(6):907–23.PubMedGoogle Scholar
  16. 16.
    Hausleiter J, Martinoff S, Hadamitzky M, et al. Image quality and radiation exposure with a low tube voltage protocol for coronary CT angiography: results of the PROTECTION II trial. JACC Cardiovasc Imaging. 2010;3(11):1113–23.PubMedGoogle Scholar
  17. 17.
    Flohr TG, McCollough CH, Bruder H, Petersilka M, Gruber K, Süß C, Grasruck M, Stierstorfer K, Krauss B, Raupach R, Primak AN, Küttner A, Achenbach S, Becker C, Kopp A, Ohnesorge BM. First performance evaluation of a dual-source CT (DSCT) system. Eur Radiol. 2006;16(2):256–68.PubMedGoogle Scholar
  18. 18.
    Johnson TR, Nikolaou K, Busch S, Leber AW, Becker A, Wintersperger BJ, Rist C, Knez A, Reiser MF, Becker CR. Diagnostic accuracy of dual-source computed tomography in the diagnosis of coronary artery disease. Investig Radiol. 2007;42(10):684–91.Google Scholar
  19. 19.
    Pontana F, Faivre JB, Remy-Jardin M, Flohr T, Schmidt B, Tacelli N, Pansini V, Remy J. Lung perfusion with dual-energy multidetector-row CT (MDCT): feasibility for the evaluation of acute pulmonary embolism in 117 consecutive patients. Acad Radiol. 2008;15(12):1494–504.PubMedGoogle Scholar
  20. 20.
    Thieme SF, Becker CR, Hacker M, Nikolaou K, Reiser MF, Johnson TR. Dual energy CT for the assessment of lung perfusion--correlation to scintigraphy. Eur J Radiol. 2008;68(3):369–74.PubMedGoogle Scholar
  21. 21.
    Achenbach S, Marwan M, Ropers D, et al. Coronary computed tomography angiography with a consistent dose below 1 mSv using prospectively electrocardiogram-triggered high-pitch spiral acquisition. Eur Heart J. 2010;31(3):340–6.PubMedGoogle Scholar
  22. 22.
    Alkadhi H, Stolzmann P, Desbiolles L, Baumueller S, Goetti R, Plass A, Scheffel H, Feuchtner G, Falk V, Marincek B, Leschka S. Low-dose, 128-slice, dual-source CT coronary angiography: accuracy and radiation dose of the high-pitch and the step-and-shoot mode. Heart. 2010;96(12):933–8.  https://doi.org/10.1136/hrt.2009.189100.PubMedGoogle Scholar
  23. 23.
    Lell M, Hinkmann F, Anders K, Deak P, Kalender WA, Uder M, Achenbach S. High-pitch electrocardiogram-triggered computed tomography of the chest: initial results. Investig Radiol. 2009;44(11):728–33.Google Scholar
  24. 24.
    Tacelli N, Remy-Jardin M, Flohr T, Faivre JB, Delannoy V, Duhamel A, Remy J. Dual-source chest CT angiography with high temporal resolution and high pitch modes: evaluation of image quality in 140 patients. Eur Radiol. 2010;20(5):1188–96.PubMedGoogle Scholar
  25. 25.
    Schulz B, Jacobi V, Beeres M, Bodelle B, Gruber T, Lee C, Bauer R, Kerl M, Vogl T, Zangos S. Quantitative analysis of motion artifacts in high-pitch dual-source computed tomography of the thorax. J Thorac Imaging. 2012;27(6):382–6.PubMedGoogle Scholar
  26. 26.
    Beeres M, Schell B, Mastragelopoulos A, Herrmann E, Kerl JM, Gruber-Rouh T, Lee C, Siebenhandl P, Bodelle B, Zangos S, Vogl TJ, Jacobi V, Bauer RW. High-pitch dual-source CT angiography of the whole aorta without ECG synchronisation: initial experience. Eur Radiol. 2012;22(1):129–37.PubMedGoogle Scholar
  27. 27.
    Wuest W, Anders K, Schuhbaeck A, May MS, Gauss S, Marwan M, Arnold M, Ensminger S, Muschiol G, Daniel WG, Uder M, Achenbach S. Dual source multidetector CT-angiography before Transcatheter Aortic Valve Implantation (TAVI) using a high-pitch spiral acquisition mode. Eur Radiol. 2012;22(1):51–8.PubMedGoogle Scholar
  28. 28.
    Plank F, Friedrich G, Bartel T, Mueller S, Bonaros N, Heinz A, Klauser A, Cartes-Zumelzu F, Grimm M, Feuchtner G. Benefits of high-pitch 128-slice dual-source computed tomography for planning of transcatheter aortic valve implantation. Ann Thorac Surg. 2012;94(6):1961–6.PubMedGoogle Scholar
  29. 29.
    Hsiao EM, Rybicki FJ, Steigner M. CT coronary angiography: 256-slice and 320-detector row scanners. Curr Cardiol Rep. 2010;12(1):68–75.  https://doi.org/10.1007/s11886-009-0075-z.PubMedPubMedCentralGoogle Scholar
  30. 30.
    Ohno Y, Koyama H, Matsumoto K, Onishi Y, Takenaka D, Fujisawa Y, Yoshikawa T, Konishi M, Maniwa Y, Nishimura Y, Ito T, Sugimura K. Differentiation of malignant and benign pulmonary nodules with quantitative first-pass 320-detector row perfusion CT versus FDG PET/CT. Radiology. 2011;258(2):599–609.PubMedGoogle Scholar
  31. 31.
    Willems PW, Taeshineetanakul P, Schenk B, Brouwer PA, Terbrugge KG, Krings T. The use of 4D-CTA in the diagnostic work-up of brain arteriovenous malformations. Neuroradiology. 2012;54(2):123–31.PubMedGoogle Scholar
  32. 32.
    Motosugi U, Ichikawa T, Sou H, Morisaka H, Sano K, Araki T. Multi-organ perfusion CT in the abdomen using a 320-detector row CT scanner: preliminary results of perfusion changes in the liver, spleen, and pancreas of cirrhotic patients. Eur J Radiol. 2012;81(10):2533–7.PubMedGoogle Scholar
  33. 33.
    US Patent X-Ray transmission scanning system and method and electron beam X-ray scan tube for use therewith. US 4352021. 1982.Google Scholar
  34. 34.
    Agatston AS, Janowitz WR, Hildner FJ, et al. Quantification of coronary artery calcium using ultrafast computed tomography. J Am Coll Cardiol. 1990;15(4):827–32.PubMedGoogle Scholar
  35. 35.
    Achenbach S, Ropers D, Regenfus M, Muschiol G, Daniel WG, Moshage W. Contrast enhanced electron beam computed tomography to analyse the coronary arteries in patients after acute myocardial infarction. Heart. 2000;84(5):489–93.PubMedPubMedCentralGoogle Scholar
  36. 36.
    Rumberger JA, Sheedy PF, Breen JF. Use of ultrafast (cine) x-ray computed tomography in cardiac and cardiovascular imaging. In: Giuliani ER, Gersh BJ, McGoon MD, Hayes DL, Schaff HF, editors. Mayo clinic practice of cardiology. 3rd ed. St. Louis: Mosby; 1996. p. 303–24.Google Scholar
  37. 37.
    Bell MR, Lerman LO, Rumberger JA. Validation of minimally invasive measurement of myocardial perfusion using electron beam computed tomography and application in human volunteers. Heart. 1999;81:628–35.PubMedPubMedCentralGoogle Scholar
  38. 38.
    Lu B, Zhuang N, Mao S, Bakhsheshhi H, Liu S, Budoff M. Image quality of three-dimensional electron beam coronary angiography. J Comput Assist Tomogr. 2002;26:202–9.PubMedGoogle Scholar
  39. 39.
    Niemann T, Henry S, Duhamel A, Faivre JB, Deschildre A, Colas L, Santangelo T, Remy J, Remy-Jardin M. Pediatric chest CT at 70 kVp: a feasibility study in 129 children. Pediatr Radiol. 2014;44(11):1347–57.PubMedGoogle Scholar
  40. 40.
    Durand S, Paul JF. Comparison of image quality between 70 kVp and 80 kVp: application to paediatric cardiac CT. Eur Radiol. 2014;24(12):3003–9.PubMedGoogle Scholar
  41. 41.
    LaBounty TM, Leipsic J, Poulter R, et al. Coronary CT angiography of patients with a normal body mass index using 80 kVp versus 100 kVp: a prospective, multicenter, multivendor randomized trial. AJR Am J Roentgenol. 2011;197(5):W860–7.PubMedGoogle Scholar
  42. 42.
    Oda S, Utsunomiya D, Funama Y, et al. A low tube voltage technique reduces the radiation dose at retrospective ECG-gated cardiac computed tomography for anatomical and functional analyses. Acad Radiol. 2011;18(8):991–9.PubMedGoogle Scholar
  43. 43.
    Nakagawa M, Ozawa Y, Sakurai K, Shimohira M, Ohashi K, Asano M, Yamaguchi S, Shibamoto Y. Image quality at low tube voltage (70 kV) and sinogram-affirmed iterative reconstruction for computed tomography in infants with congenital heart disease. Pediatr Radiol. 2015;45(10):1472–9.PubMedPubMedCentralGoogle Scholar
  44. 44.
    Duan X, Wang J, Leng S, Schmidt B, Allmendinger T, Grant K, Flohr T, McCollough CH. Electronic noise in CT detectors: impact on image noise and artifacts. AJR Am J Roentgenol. 2013;201(4):W626–32.PubMedGoogle Scholar
  45. 45.
    Flohr T, Stierstorfer K, Raupach R, Ulzheimer S, Bruder H. Performance evaluation of a 64-slice CT-system with z-flying focal spot. Rofo. 2004;176:1803–10.PubMedGoogle Scholar
  46. 46.
    Flohr TG, Stierstorfer K, Ulzheimer S, Bruder H, Primak AN, McCollough CH. Image reconstruction and image quality evaluation for a 64-slice CT scanner with z-flying focal spot. Med Phys. 2005;32(8):2536–47.PubMedGoogle Scholar
  47. 47.
    Lee AM, Beaudoin J, Engel LC, Sidhu MS, Abbara S, Brady TJ, Hoffmann U, Ghoshhajra BB. Assessment of image quality and radiation dose of prospectively ECG-triggered adaptive dual-source coronary computed tomography angiography (cCTA) with arrhythmia rejection algorithm in systole versus diastole: a retrospective cohort study. Int J Cardiovasc Imaging. 2013;29(6):1361–70.PubMedGoogle Scholar
  48. 48.
    Flohr TG, Schoepf UJ, Ohnesorge BM. Chasing the heart: new developments for cardiac CT. J Thorac Imaging. 2007;22(1):4–16.PubMedGoogle Scholar
  49. 49.
    Muenzel D, Noel PB, Dorn F, Dobritz M, Rummeny EJ, Huber A. Coronary CT angiography in step-and-shoot technique with 256-slice CT: impact of the field of view on image quality, craniocaudal coverage, and radiation exposure. Eur J Radiol. 2012;81(7):1562–8.PubMedGoogle Scholar
  50. 50.
    Klass O, Walker M, Siebach A, Stuber T, Feuerlein S, Juchems M, Hoffmann MH. Prospectively gated axial CT coronary angiography: comparison of image quality and effective radiation dose between 64- and 256-slice CT. Eur Radiol. 2010;20(5):1124–31.PubMedGoogle Scholar
  51. 51.
    Rybicki FJ, Otero HJ, Steigner ML, Vorobiof G, Nallamshetty L, Mitsouras D, Ersoy H, Mather RT, Judy PF, Cai T, Coyner K, Schultz K, Whitmore AG, Di Carli MF. Initial evaluation of coronary images from 320-detector row computed tomography. Int J Cardiovasc Imaging. 2008;24(5):535–46.PubMedGoogle Scholar
  52. 52.
    Tomizawa N, Maeda E, Akahane M, Torigoe R, Kiryu S, Ohtomo K. Coronary CT angiography using the second-generation 320-detector row CT: assessment of image quality and radiation dose in various heart rates compared with the first-generation scanner. Int J Cardiovasc Imaging. 2013;29(7):1613–8.PubMedGoogle Scholar
  53. 53.
    Engel KJ, Herrmann C, Zeitler G. X-ray scattering in single- and dual-source CT. Med Phys. 2008;35(1):318–32.PubMedGoogle Scholar
  54. 54.
    Vogtmeier G, Dorscheida R, Engela KR, Luhtab K, Mattsonb R, Harwoodb B, Applebyc M, Randolphc B, KlingerVogtmeier J, et al. Two-dimensional anti-scatter grids for computed tomography detectors. Medical imaging. International Society for Optics and Photonics. 2008.Google Scholar
  55. 55.
    Li B, Toth TL, Hsieh J, et al. Simulation and analysis of image quality impacts from single source, ultra-wide coverage CT scanner. J Xray Sci Technol. 2012;20(4):395–404.PubMedGoogle Scholar
  56. 56.
    Chen MY, Shanbhag SM, Arai AE. Submillisievert median radiation dose for coronary angiography with a second-generation 320-detector row CT scanner in 107 consecutive patients. Radiology. 2013;267(1):76–85.PubMedPubMedCentralGoogle Scholar
  57. 57.
    Nasis A, Leung MC, Antonis PR, Cameron JD, Lehman SJ, Hope SA, Crossett MP, Troupis JM, Meredith IT, Seneviratne SK. Diagnostic accuracy of noninvasive coronary angiography with 320-detector row computed tomography. Am J Cardiol. 2010;106(10):1429–35.PubMedGoogle Scholar
  58. 58.
    Kondo T, Kumamaru KK, Fujimoto S, Matsutani H, Sano T, Takase S, Rybicki FJ. Prospective ECG-gated coronary 320-MDCT angiography with absolute acquisition delay strategy for patients with persistent atrial fibrillation. AJR Am J Roentgenol. 2013;201(6):1197–203.PubMedGoogle Scholar
  59. 59.
    George RT, Mehra VC, Chen MY, Kitagawa K, Arbab-Zadeh A, Miller JM, Matheson MB, Vavere AL, Kofoed KF, Rochitte CE, Dewey M, Yaw TS, Niinuma H, Brenner W, Cox C, Clouse ME, Lima JA, Di Carli M. Myocardial CT perfusion imaging and SPECT for the diagnosis of coronary artery disease: a head-to-head comparison from the CORE320 multicenter diagnostic performance study. Radiology. 2015;274(2):626.PubMedPubMedCentralGoogle Scholar
  60. 60.
    Sharma RK, Arbab-Zadeh A, Kishi S, Chen MY, Magalhães TA, George RT, Dewey M, Rybicki FJ, Kofoed KF, de Roos A, Tan SY, Matheson M, Vavere A, Cox C, Clouse ME, Miller JM, Brinker JA, Arai AE, Di Carli MF, Rochitte CE, Lima JA. Incremental diagnostic accuracy of computed tomography myocardial perfusion imaging over coronary angiography stratified by pre-test probability of coronary artery disease and severity of coronary artery calcification: the CORE320 study. Int J Cardiol. 2015;201:570–7.PubMedGoogle Scholar
  61. 61.
    So A, Imai Y, Nett B, Jackson J, Nett L, Hsieh J, Wisenberg G, Teefy P, Yadegari A, Islam A, Lee TY. Technical Note: Evaluation of a 160-mm/256-row CT scanner for whole-heart quantitative myocardial perfusion imaging. Med Phys. 2016;43(8):4821.  https://doi.org/10.1118/1.4957389.PubMedGoogle Scholar
  62. 62.
  63. 63.
    Sun ML, Lu B, Wu RZ, Johnson L, Han L, Liu G, Yu FF, Hou ZH, Gao Y, Wang HY, Jiang S, Yang YJ, Qiao SB. Diagnostic accuracy of dual-source CT coronary angiography with prospective ECG-triggering on different heart rate patients. Eur Radiol. 2011;21(8):1635–42.PubMedGoogle Scholar
  64. 64.
    Lee AM, Engel LC, Shah B, Liew G, Sidhu MS, Kalra M, Abbara S, Brady TJ, Hoffmann U, Ghoshhajra BB. Coronary computed tomography angiography during arrhythmia: radiation dose reduction with prospectively ECG-triggered axial and retrospectively ECG-gated helical 128-slice dual-source CT. J Cardiovasc Comput Tomogr. 2012;6(3):172–183.e2.PubMedGoogle Scholar
  65. 65.
    Paul JF, Amato A, Rohnean A. Low-dose coronary-CT angiography using step and shoot at any heart rate: comparison of image quality at systole for high heart rate and diastole for low heart rate with a 128-slice dual-source machine. Int J Cardiovasc Imaging. 2013;29(3):651–7.PubMedGoogle Scholar
  66. 66.
    Westwood ME, Raatz HD, Misso K, Burgers L, Redekop K, Lhachimi SK, Armstrong N, Kleijnen J. Systematic review of the accuracy of dual-source cardiac CT for detection of arterial stenosis in difficult to image patient groups. Radiology. 2013;267(2):387–95.PubMedGoogle Scholar
  67. 67.
    Sidhu MS, Venkatesh V, Hoffmann U, et al. Advanced adaptive axial-sequential prospectively electrocardiogram-triggered dual-source coronary computed tomographic angiography in a patient with atrial fibrillation. J Comput Assist Tomogr. 2011;35(6):747–8.PubMedGoogle Scholar
  68. 68.
    Hutt A, Tacelli N, Faivre JB, Flohr T, Duhamel A, Remy J, Remy-Jardin M. Is bronchial wall imaging affected by temporal resolution? Comparative evaluation at 140 and 75 ms in 90 patients. Eur Radiol. 2016;26(2):469–77.PubMedGoogle Scholar
  69. 69.
    Petersilka M, Stierstorfer K, Bruder H, Flohr T. Strategies for scatter correction in dual source CT. Med Phys. 2010;37(11):5971–92.PubMedGoogle Scholar
  70. 70.
    T G F, Leng S, Yu L, Allmendinger T, Bruder H, Petersilka M, Eusemann CD, Stierstorfer K, Schmidt B, McCollough C. Dual-source spiral CT with pitch up to 3.2 and 75 ms temporal resolution: image reconstruction and assessment of image quality. Med Phys. 2009;36(12):5641–53.Google Scholar
  71. 71.
    Hou DJ, Tso DK, Davison C, Inacio J, Louis LJ, Nicolaou S, Reimann AJ, Hou DJ, Tso DK, Davison C, Inacio J, Louis LJ, Nicolaou S, Reimann AJ. Clinical utility of ultra high pitch dual source thoracic CT imaging of acute pulmonary embolism in the emergency department: are we one step closer towards a non-gated triple rule out? Eur J Radiol. 2013;82(10):1793–8.Google Scholar
  72. 72.
    Apfaltrer P, Hanna EL, Schoepf UJ, Spears JR, Schoenberg SO, Fink C, Vliegenthart R. Radiation dose and image quality at high-pitch CT angiography of the aorta: intraindividual and interindividual comparisons with conventional CT angiography. AJR Am J Roentgenol. 2012;199(6):1402–9.PubMedGoogle Scholar
  73. 73.
    Han BK, Overman DM, Grant K, et al. Non-sedated, free breathing cardiac CT for evaluation of complex congenital heart disease in neonates. J Cardiovasc Comput Tomogr. 2013;7(6):354–60.PubMedGoogle Scholar
  74. 74.
    Lee JH, Han D, Danad I, et al. Multimodality imaging in coronary artery disease: focus on computed tomography. J Cardiovasc Ultrasound. 2016;24(1):7–17.PubMedPubMedCentralGoogle Scholar
  75. 75.
    Lell MM, May M, Deak P, Alibek S, Kuefner M, Kuettner A, Köhler H, Achenbach S, Uder M, Radkow T. High-pitch spiral computed tomography: effect on image quality and radiation dose in pediatric chest computed tomography. Investig Radiol. 2011;46(2):116–23.Google Scholar
  76. 76.
    Bridoux A, Hutt A, Faivre JB, Flohr T, Duhamel A, Pagniez J, Remy J, Remy-Jardin M. Coronary artery visibility in free-breathing young children on non-gated chest CT: impact of temporal resolution. Pediatr Radiol. 2015;45(12):1761–70.PubMedGoogle Scholar
  77. 77.
    Achenbach S, Marwan M, Schepis T, Pflederer T, Bruder H, Allmendinger T, Petersilka M, Anders K, Lell M, Kuettner A, Ropers D, Daniel WG, Flohr T. High-pitch spiral acquisition: a new scan mode for coronary CT angiography. J Cardiovasc Comput Tomogr. 2009;3:117–21.PubMedGoogle Scholar
  78. 78.
    Leschka S, Stolzmann P, Desbiolles L, Baumueller S, Goetti R, Schertler T, Scheffel H, Plass A, Falk V, Feuchtner G, Marincek B, Alkadhi H. Diagnostic accuracy of high-pitch dual-source CT for the assessment of coronary stenoses: first experience. Eur Radiol. 2009;19(12):2896–903.PubMedGoogle Scholar
  79. 79.
    Gordic S, Husarik DB, Desbiolles L, Leschka S, Frauenfelder T, Alkadhi H. High-pitch coronary CT angiography with third generation dual-source CT: limits of heart rate. Int J Cardiovasc Imaging. 2014;30(6):1173–9.PubMedGoogle Scholar
  80. 80.
    Morsbach F, Gordic S, Desbiolles L, Husarik D, Frauenfelder T, Schmidt B, Allmendinger T, Wildermuth S, Alkadhi H, Leschka S. Performance of turbo high-pitch dual-source CT for coronary CT angiography: first ex vivo and patient experience. Eur Radiol. 2014;24(8):1889–95.PubMedGoogle Scholar
  81. 81.
    Azzalini L, Abbara S, Ghoshhajra BB. Ultra-low contrast computed tomographic angiography (CTA) with 20-mL total dose for transcatheter aortic valve implantation (TAVI) planning. J Comput Assist Tomogr. 2014;38(1):105–9.PubMedGoogle Scholar

Copyright information

© Humana Press 2019

Authors and Affiliations

  • Bernhard Schmidt
    • 1
    Email author
  • Katharine Grant
    • 2
  • Thomas G. Flohr
    • 1
  • Thomas Allmendinger
    • 1
  1. 1.Department of Computed TomographySiemens Healthcare GmbHForchheimGermany
  2. 2.Siemens Medical Solutions USA, Inc.MalvernUSA

Personalised recommendations