Arterial pressure is one of the most widely measured cardiovascular variables, but the ideal technique has yet to be developed. A number of methods have been described, all of which have their own advantages and disadvantages. Central to any consideration of these is an appreciation of the enormous variability of blood pressure: a single measurement of pressure made at a discrete point in time may have very little meaning. This is particularly relevant to behaviorally oriented studies, where the emphasis is commonly on the transient changes of pressure occurring in response to a behavioral challenge. Therefore, methods capable of taking multiple measurements over a relatively short space of time are desirable. Currently available methods are reviewed below.

Keywords

Pulse Wave Velocity Brachial Artery Diastolic Pressure Cuff Pressure Pulse Transit Time 
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Aaslid, R., & Brubakk, A. O. (1981). Accuracy of an ultrasound Doppler servo method for noninvasive determination of instantaneous and mean arterial blood pressure. Circulation, 64, 753–759.PubMedCrossRefGoogle Scholar
  2. Ayman, P., & Goldshine, A. D. (1940). Blood pressure determinations by patients with essential hypertension. I. The difference between clinic and home readings before treatment. American Journal of Medical Science, 200, 465–474.CrossRefGoogle Scholar
  3. Blank, S. G., West, J. E., Mueller, F. B., Cody, R. J., Harshfield, G. A., Pecker, M. S., Laragh, J. H., & Pickering, T. G. (1988). Wideband external pulse recording during cuff deflation: A new technique for evaluation of the arterial pressure pulse and measurement of blood pressure. Circulation, 77, 1297–1305.PubMedCrossRefGoogle Scholar
  4. Burke, M. J., Towers, H. M., O’Malley, K., Fitzgerald, D. J., & O’Brien, E. T. (1982). Sphygmomanometers in hospital and family practice: Problems and recommendations. British Medical Journal, 285, 469–471.PubMedCrossRefGoogle Scholar
  5. Carey, R. M., Reid, R. A., Ayers, C. R., Lynch, S. S., McLain, W. L., & Vaughan, E. D. (1976). The Charlottesville Blood Pressure Survey: Value of repeated blood pressure measurements. Journal of the American Medical Association, 236, 847–851.PubMedCrossRefGoogle Scholar
  6. Clement, D. L., Jordaens, L. J., & Heyndrickx, G. R. (1984). Influence of vagai nervous activity on blood pressure variability. Journal of Hypertension, 2 (Suppl. 3), 391–393.Google Scholar
  7. Comstock, G. W. (1957). An epidemiologic study of blood pressure levels in a biracial community in the southern United States. American Journal of Hygiene, 65, 271–315.PubMedGoogle Scholar
  8. Dock, W. (1980). Occasional notes—Korotkoff sounds. New England Journal of Medicine, 302, 1264–1267.PubMedCrossRefGoogle Scholar
  9. Dornhorst, A. C., Howard, P., & Leathart, G. L. (1952). Respiratory variations in blood pressure. Circulation, 6, 553–558.PubMedCrossRefGoogle Scholar
  10. Elseed, A. M., Shinebourne, E. A., & Joseph, M. C. (1973). Assessment of techniques for measurement of blood pressure in infants and children. Archives of Disease in Childhood, 48, 932–936.PubMedCrossRefGoogle Scholar
  11. Frohlich, E. D., Tarazi, R. C., Ulrych, M., Dustan, H. P., & Page, I. H. (1967). Tilt test for investigating a neural component in hypertension: Its correlation with clinical characteristics. Circulation, 36, 387–393.PubMedCrossRefGoogle Scholar
  12. Geddes, L. A. (1984). Cardiovascular devices and their applications. New York: Wiley.Google Scholar
  13. Gould, B. A., Hornung, R. S., Altaian, D. G., Cashman, P. M. M., & Raftery, E. B. (1985). Indirect measurement of blood pressure during exercise testing can be misleading. British Heart Journal, 53, 611–615.PubMedCrossRefGoogle Scholar
  14. Henschel, A., DeLaVega, F., & Taylor, H. L. (1954). Simultaneous direct and indirect blood pressure measurements in man at rest and work. Journal of Applied Physiology, 5, 506–508.Google Scholar
  15. Heymans, C., & Neil, E. (1958). Reflexogenic areas of the cardiovascular system (pp. 180–181). London: Churchill.Google Scholar
  16. Hochberg, H. M., & Solomon, H. (1971). Accuracy of an automated ultrasound blood pressure monitor. Current Therapeutic Research, 13, 129–138.PubMedGoogle Scholar
  17. Kirkendall, W. M., Burton, A. C., Epstein, F. H., & Fries, E. D. (1967). American Heart Association Recommendations for human blood pressure determinations by sphygmomanometers. Circulation, 36, 980.PubMedCrossRefGoogle Scholar
  18. Kirkendall, W. M., Feinlieb, M., Fries, E. D., & Mark, A. L. (1981). American Heart Association Recommendations for human blood pressure determination by sphygmomanometer. Hypertension, 3, 510a–519a.PubMedGoogle Scholar
  19. Kroeker, E. J., & Wood, E. H. (1956). Beat-to-beat alterations in relationship to simultaneously recorded central and peripheral arterial pressure pulses during Valsalva maneuver and prolonged expiration in man. Journal of Applied Physiology, 8, 483–494.PubMedGoogle Scholar
  20. Labarthe, D. R., Hawkins, C. M., & Remington, R. D. (1973). Evaluation of performance of selected devices for measuring blood pressure. American Journal of Cardiology, 32, 546–553.PubMedCrossRefGoogle Scholar
  21. Lane, J. E., Greenstadt, L., & Shapiro, D. (1983). Pulse transit time and blood pressure: An intensive analysis. Psychophysiology, 20, 45–49.PubMedCrossRefGoogle Scholar
  22. Mancia, G., Bertini, G., Grassi, G., Pomidossi, G., Gregorini, L., Bertinieri, G., Parati, G., Ferrari, A., & Zanchetti, A. (1983). Effects of blood pressure measurement by the doctor on patients’ blood pressure and heart rate. Lancet, 2, 695–697.PubMedCrossRefGoogle Scholar
  23. Marey, E. J. (1876). Pression et vitesse du sang. Physiologie Experimentale, Paris. Pratique des hautes etudes lab de M. Marey.Google Scholar
  24. Mauck, G. B., Smith, C. R., Geddes, L. R., & Bourland, J. D. (1980). The meaning of the point of maximum oscillations in cuff pressure in the indirect measurement of blood pressure II. Journal of Biomechanical Engineering, 102, 28–33.PubMedCrossRefGoogle Scholar
  25. Maxwell, M. H., Waks, A. V., Schroth, P. C., Karam, M., & Dornfeld, L. (1982). Error in blood pressure measurement due to incorrect cuff size in obese patients. Lancet, 2, 33–35.PubMedCrossRefGoogle Scholar
  26. McCutcheon, E. P., & Rushmer, R. F. (1967). Korotkoff sounds: An experimental critique. Circulation Research, 20, 149–161.PubMedCrossRefGoogle Scholar
  27. Molhoek, P. G., Wesseling, K. H., Arntzenius, C., Settels, J. J. M., VanVollenhoven, E., & Weeda, H. W. H. (1983). Initial results of non-invasive measurement of finger blood pressure according to Penaz. Automedica, 4, 241–246.Google Scholar
  28. Nielsen, P. E., & Janniche, H. (1974). The accuracy of auscultatory measurement of arm blood pressure in very obese subjects. Acta Medica Scandinavica, 195, 403–409.PubMedCrossRefGoogle Scholar
  29. O’Rourke, M. (1984). Wave reflection and the arterial pulse. Archives of Internal Medicine, 144, 366.PubMedCrossRefGoogle Scholar
  30. Penaz, J. (1973). Photo-electric measurement of blood pressure, volume and flow in the finger. Digest Tenth International Conference on Medical and Biological Engineering, Dresden, p. 104.Google Scholar
  31. Pickering, G. W. (1968). High blood pressure. London: Churchill.Google Scholar
  32. Pickering, T. G., Harshfield, G. A., Devereux, R. B., & Laragh, J. H. (1985). What is the role of ambulatory blood pressure monitoring in the management of hypertensive patients?. Hypertension, 7, 171–177.PubMedCrossRefGoogle Scholar
  33. Pickering, T. G., Cvetkovski, B., & James, G. D. (1986). An evaluation of electronic recorders for self monitoring of blood pressure. Journal of Hypertension, 4 (Suppl.), S329–S330.Google Scholar
  34. Pollack, M. H., & Obrist, P. A. (1983). Aortic-radial pulse transit time and ECG Q-wave to radial pulse wave interval as indices of beat-to-beat blood pressure change. Psychophysiology, 20, 21–28.CrossRefGoogle Scholar
  35. Ramsey, M. (1979). Noninvasive automatic determination of mean arterial pressure. Medical and Biological Engineering and Computing, 17, 11–18.PubMedCrossRefGoogle Scholar
  36. Reder, R. F., Dimich, I., Cohen, M. L., & Steinfeld, L. (1978). Evaluating indirect blood pressure measurement techniques: A comparison of three systems in infants and children. Pediatrics, 62, 326–330.PubMedGoogle Scholar
  37. Shapiro, D., Schwartz, G. E., & Tursky, B. (1972). Control of diastolic blood pressure in man by feedback and reinforcement. Psychophysiology, 9, 296–304.PubMedCrossRefGoogle Scholar
  38. Short, D. (1976). The diastolic dilemma. British Medical Journal, 2, 685–686.PubMedCrossRefGoogle Scholar
  39. Spence, J. D., Sibbald, W. J., & Cape, R. D. (1978). Pseudohypertension in the elderly. Clinical Science and Molecular Medicine, 55, 399s-402s.Google Scholar
  40. Steinfeld, L., Dimich, I., Reder, R., Cohen, M., & Alexander, H. (1978). Sphygmomanometry in the pediatric patients. Journal of Pediatrics, 92, 934–938.PubMedCrossRefGoogle Scholar
  41. Steptoe, A., Smulyan, H., & Gribbin, B. (1976). Pulse wave velocity and blood pressure change: Calibration and applications. Psychophysiology, 13, 488–493.PubMedCrossRefGoogle Scholar
  42. Streeten, D. H. P., Auchincloss, J. H., Anderson, G. H., Richardson, R. L., Thomas, F. D., & Miller, J. W. (1985). Orthostatic hypertension: Pathogenetic studies. Hypertension, 7, 196–203.PubMedCrossRefGoogle Scholar
  43. Ware, R. W., & Laenger, C. J. (1967). Indirect blood pressure measurement by Doppler ultrasonic kinetoarteriography. Proceedings of the 20th Annual Conference on Engineering in Medicine and Biology, 9, 27–30.Google Scholar
  44. Webster, J., Newnham, D., Petrie, J. C., & Lovell, H. G. (1984). Influence of arm position on measurement of blood pressure. British Medical Journal, 228, 1574–1575.CrossRefGoogle Scholar
  45. Wesseling, K. H., deWit, B., Settels, J. J., & Klawer, W. H. (1982). On the indirect registration of finger blood pressure after Penaz. Funktionale Biologie und Medizin, 245, 245–250.Google Scholar
  46. West, J. E., Busch-Vishniac, I. J., Harshfield, G. A., & Pickering, T. G. (1983). Foil electret transducer for blood pressure monitoring. Journal of the Acoustical Society of America, 74, 680–686.PubMedCrossRefGoogle Scholar
  47. Wright, B. M., & Dore, C. F. (1970). A random-zero sphyg-momanometer. Lancet, 1, 337–338.PubMedGoogle Scholar
  48. Yelderman, M., & Ream, A. K. (1979). Indirect measurement of mean blood pressure in the anesthetized patient. Anesthesiology, 50, 253–256.PubMedCrossRefGoogle Scholar

Copyright information

© Springer Science+Business Media New York 1989

Authors and Affiliations

  • Thomas G. Pickering
    • 1
  • Seymour G. Blank
    • 1
  1. 1.Department of Medicine, Cardiovascular CenterNew York Hospital-Cornell Medical CenterNew YorkUSA