Hemodynamic Model for Determination of Asymmetric Flow

  • W. J. DorsonJr.
  • J. Marks
  • D. Hunkar
Conference paper

Abstract

The application of engineering principles and in vitro (outside the body) research with biological fluids is becoming increasingly important in the design of prosthetic and diagnostic devices. One area of medicine where both theoretical and experimental studies are needed is the flow of blood in the human body. Blood is a suspension of red cells in an ionic solution containing proteins and organic compounds. The flowing blood carries nutrients to the organs and removes waste material. The red cells are distensible, and the flow of blood is non-Newtonian and has a yield stress at zero flow. Measurement of the flow rate and vascular volumes in specific areas of the human body are important for several reasons. Flow deficiency through major arteries is symptomatic of a diseased state, including major stroke, heart failure, arteriosclerosis, and senility syndromes. The exact mechanism of nutrient transfer in the capillary beds is unknown in terms of the relative contribution of mass and electrochemical transport. Such studies require an accurate measurement of regional blood flow and composition changes.

Keywords

Carotid Artery Shear Rate Entrance Length Asymmetric Flow Flow Difference 
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. 1.
    Hollenberg, N. K., “Development of Modern Methods of Blood Flow Measurement,” Paper No. 69, MEDAC 1966, AAMI.Google Scholar
  2. 2.
    Jackson, B., “The Use of the Electromagnetic Flowmeter in Clinical and Physiological Studies,” Paper No. 70, MEDAC 1966, AAMI.Google Scholar
  3. 3.
    Dexter, L., “Indicator-Dilution Method of Measuring Cardiac Output,” Paper No. 71, MEDAC 1966, AAMI.Google Scholar
  4. 4.
    Morgan, C. L., Rushmer, R. F., and Baker, D. W., “The Transcutaneous Doppler Flow Detector,” Paper No. 72, MEDAC 1966, AAMI.Google Scholar
  5. 5.
    Herd, J. A., “Intrarenal Distribution of Blood Flow in the Unanaesthetized Dog Measured Using Kr-85,” Paper No. 73, MEDAC 1966, AAMI.Google Scholar
  6. 6.
    Dorson, W. J., Hunkar, D. B., and Marks, J. M., “A Medical Computer System Applied to Asymmetric Blood Flow Determination,” Paper No. 75, MEDAC 1966, AAMI.Google Scholar
  7. 7.
    Stewart, G. N., “Researches on the Circulation Time in Organs and on the Influences Which Affect It,” J. Physiol., 15, 1893, p. 1.Google Scholar
  8. 8.
    Hamilton, W. F., Kinsnian, J. M. and Moore, J. W., “Studies on the Circulation,” Am. J. Physiol., 89, 1929, p. 322.Google Scholar
  9. 9.
    Rossi, H. H., Powers, S. H., and Dwork, B., “Measurement of Flow in Straight Tubes by Means of the Dilution Technique,” Am. J. Physiol., 173, 1953, p. 103.Google Scholar
  10. 10.
    Fox, I. J., “History and Development Aspects of the Indicator-Dilution Technic,” Circulation Res., 16, 1962, p. 381.CrossRefGoogle Scholar
  11. 11.
    Kety, S. S., “Theory of Blood-Tissue Exchange and Its Application to Measurement of Blood Flow,” In: Methods In Medical Research by H. D. Bruner, Year Book Publishers, Inc., Chicago, 8, 1960, p. 223Google Scholar
  12. 12.
    Zierler, K. L., “Equations for Measuring Blood Flow by External Monitoring of Radioisotopes,” Circulation Res., 16, 1965, p. 309.CrossRefGoogle Scholar
  13. 13.
    Oldendorf, W. H., Kitano, M., Shimizu, S., ”Evaluation of a Simple Technique for Abrupt Intravenous Injection of Radioisotopes,” J. Nuclear Med., 63; pp. 205–209; 1965Google Scholar
  14. 14.
    Copley, A. L. and Stainsby, G., Flow Properties of Blood and Other Biological Systems, London, Pergamon Press, 1960Google Scholar
  15. 15.
    Dorson, W. J., “Factors Affecting the Flow of Blood and Newtonian Liquids in Small Bore Capillary Tubing,” Ph.D. Thesis, University of Cincinnati, Cincinnati, Ohio, 1966.Google Scholar
  16. 16.
    Merrill, E. W., et. al., “Pressure Flow Relations of Human Blood in Hollow Fibers at Low Flow Rates,” J. Appl. Physiol., 20: 954; 1965.Google Scholar
  17. 17.
    Hardesty, W. H., et. al., “Studies of Carotid Artery Blood Flow in Man,” N.E.J.M., 263, 944; 1960.CrossRefGoogle Scholar
  18. 18.
    Merrill, E. W. and Wells, R. E., “Flow Properties of Biological Fluids,” Appl. Mech. Rev., 14: 663; 1961Google Scholar
  19. 19.
    Strumia, M. M. and Phillips, M., “Effects of Red Cell Factors on the Relative Viscosity of Whole Blood,” Am. J. Clin. Path., 36: 464; 1963.Google Scholar
  20. 20.
    Dreizen, P., “Rheology of Human Blood, Studies on the Flow of Fresh Venous Blood and of Citrated Blood Through Tubing of Diameters between 0.09 and 0.20 cm.”, J. Clin. Invest., 41: 2036; 1962.CrossRefGoogle Scholar
  21. 21.
    Langhaar, H. L., “Steady Flow in the Transition Length of a Straight Tube,” J. Appl. Mech., p. A-55; June, 1942.Google Scholar
  22. 22.
    Oldendorf, W. H., “Monitoring Certain Aspects of the Cranial Blood Pool,” Proceedings of the San Diego Symposium for Bio-medical Engineering, p. 65; 1963.Google Scholar

Copyright information

© Springer Science+Business Media New York 1967

Authors and Affiliations

  • W. J. DorsonJr.
    • 1
  • J. Marks
    • 2
  • D. Hunkar
    • 3
  1. 1.Arizona State UniversityTempeUSA
  2. 2.Grant HospitalColumbusUSA
  3. 3.University of CincinnatiCincinnatiUSA

Personalised recommendations