Handling Liquid Hydrogen on a Pilot-Plant Scale

  • H. L. Laquer
Conference paper
Part of the Advances in Cryogenic Engineering book series (ACRE, volume 5)

Abstract

The following discussion summarizes experience obtained during the last 3 years while handling liquid hydrogen in 5500-liter batches. The work was not an-objective in itself, nor is it complete or exhaustive, but was done only coincidentally while developing and operating a liquid-hydrogen-cooled electromagnet [1, 2]. The quantities of liquid handled are small by missile standards, but the problems encountered on this pilot-plant scale are much nearer to those of large-scale usage than those of normal laboratory usage. The scaling of volumes would be from 1 gal in the laboratory to 1000 gal in our magnet to perhaps 100,000 gal for missile testing.

Keywords

Check Valve Liquid Hydrogen Heat Leak Carbon Resistor Teflon Gasket 
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. 1.
    H. L. Laquer, “The Los Alamos high field magnet,” 1956 Cryogenic Engineering Conference Proceedings.Google Scholar
  2. 2.
    H. L. Laquer and E.F.Hammel, “Cryogenic electromagnets, I. Feasibility study,”Rev, Sci. Instr., Vol. 28, p. 875 (1957).CrossRefGoogle Scholar
  3. 3.
    V. E. Isakson, C. D. Holben, and C. V. Fogelberg, “Beech Aircraft 6000 liter liquid hydrogen dewar,” 1957 Cryogenic Engineering Conference Proceedings.Google Scholar
  4. 4.
    J. E. Harlow, E. L. Murley, and H. L. Laquer, present volume, p. 580.Google Scholar

Copyright information

© Springer Science+Business Media New York 1960

Authors and Affiliations

  • H. L. Laquer
    • 1
  1. 1.Los Alamos Scientific LaboratoryLos AlamosUSA