Nowadays, many industries are using non-conventional energy sources to generate a huge amount of power/electricity, as these are non-pollutant. But connecting wind turbine to the power system or grid may lead to power quality issues such as voltage sag/swell, flicker, and harmonic and inter-harmonics. DVR is one of the CP devices used to mitigate voltage drop/raise (Srivastav and Sharma in Int J Adv Res Electr Electron Instr Eng 6(5), 2017 [1]). Sag is a more critical issue than swell. In this paper, sag and harmonic problems have been addressed. It demonstrates that how DVR injects voltage to compensate sags and reduces harmonics during fault. Here, the performance of DVR with PI controller, fuzzy controller, and hybrid fuzzy logic controller has been compared. The demonstration is done in MATLAB/Simulink.
Keywords
This is a preview of subscription content, log in via an institution.
Buying options
Tax calculation will be finalised at checkout
Purchases are for personal use only
Learn about institutional subscriptionsReferences
M. Srivastav, R. Sharma, Power quality improvement of distribution networks using dynamic voltage restore. Int J Adv Res Electr Electron Instr Eng 6(5), (2017). https://doi.org/10.15662/ijareeie.2017.0605034
M.N. Eskander, S.I. Amer, Mitigation of voltage dips and swells in grid connected wind energy conversion systems. IETE J Res 57(6), 515 (2011)
M. IIyas, Y. Rana, J.S. Khan, Analysis of the grid connected wind energy system using MATLAB/Simulink. Int J Adv Res Electr Electron Instr Eng 4(7), (2015)
D. Francis, T. Thomas, Mitigation of voltage sag and swell using dynamic voltage restorer. in International Conference on Magnetics and Drives (AICERA-2014 iCMMD)
P. Keertana, A. Chandana, Power quality enhancement for DFIG system by using HFLC based UPQC. Int J Adv Res Eng 7(02), (2018)
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2020 Springer Nature Singapore Pte Ltd.
About this paper
Cite this paper
Chandrika, B., Sujatha, B.C. (2020). Voltage Sag Mitigation for PMSG System Using DVR Based Hybrid Fuzzy Logic Controller. In: Saini, H., Srinivas, T., Vinod Kumar, D., Chandragupta Mauryan, K. (eds) Innovations in Electrical and Electronics Engineering. Lecture Notes in Electrical Engineering, vol 626. Springer, Singapore. https://doi.org/10.1007/978-981-15-2256-7_47
Download citation
DOI: https://doi.org/10.1007/978-981-15-2256-7_47
Published:
Publisher Name: Springer, Singapore
Print ISBN: 978-981-15-2255-0
Online ISBN: 978-981-15-2256-7
eBook Packages: EngineeringEngineering (R0)