Abstract
Intermittent heating is commonly applied and considered as energy efficient in public buildings in cold areas considering their occupation schedules. Rational preheating time is of significance to guarantee indoor thermal comfort, facility safety and energy conservation in intermittent operation strategy. In this paper, indoor temperature and energy consumption under continuous and intermittent heating conditions of a typical office building in Shijiazhuang City, China, are, respectively, studied using DeST-C software. The influence of building thermal parameters and outdoor temperature on preheating time is also studied. The results show that indoor temperature fluctuates periodically within a larger margin in a day under intermittent heating while it is relatively stable under continuous heating. The lowest indoor temperature of energy-efficient buildings and ordinary ones is as low as 11 and 9 °C, respectively, under intermittent heating during the coldest days in winter. The preheating time for energy-efficient buildings is 2, 2 and 1 h; for non-energy-efficient buildings, it is 3, 3 and 1 h during the early, peak and final heating period. The energy-saving rate of intermittent heating compared with the continuous heating mode is above 20% for both energy-efficient buildings and ordinary ones in cold area.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Wang, E.: Research on energy consumption and operation strategy of different heating system in intermittent operating condition. Master Degree’s Thesis of Harbin Institute of Technology (in Chinese) (2016)
Xu, B., et al.: An intermittent heating strategy by predicting warm-up time for office buildings in Beijing. Energy Build. 155, 35–42 (2017)
Wang, Z., et al.: A model to compare convective and radiant heating systems for intermittent space heating. Appl. Energy 215, 211–226 (2018)
Badran, A.A., et al.: Comparative study of continuous versus intermittent heating for local residential building: case studies in Jordan. Energy Convers. Manag. 65, 709–714 (2013)
Cardinale, N., Stefanizzi, P.: Heating-energy consumption in different plant operating conditions. Energy Build. 24(3), 231–235 (1996)
Wang, Z., et al.: Modeling and measurement study on an intermittent heating system of a residence in Cambridgeshire. Build. Environ. 92, 380–386 (2015)
Pupeikis, D., et al.: Required additional heating power of building during intermitted heating. J. Civ. Eng. Manag. 16(1), 141–148 (2010)
Chen, F., Deng, Y.: Building Environment Design Simulation Toolkit DeST. J. HVAC 29(4), 58–63 (1999)
Lu, Y.: Practical HV & AC Design Handbook. China Architecture & Building Press, Beijing (2008)
Acknowledgements
This project is supported by National 13th Five-Year Science and Technology Support Program (2016YFC0700707) and Natural Science Foundation of Hebei Province, China (E2015202063).
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2020 Springer Nature Singapore Pte Ltd.
About this paper
Cite this paper
Sun, C., Chen, J., Liang, Y., Cao, S. (2020). Preheating Strategy of Intermittent Heating for Public Buildings in Cold Areas of China. In: Wang, Z., Zhu, Y., Wang, F., Wang, P., Shen, C., Liu, J. (eds) Proceedings of the 11th International Symposium on Heating, Ventilation and Air Conditioning (ISHVAC 2019). ISHVAC 2019. Environmental Science and Engineering(). Springer, Singapore. https://doi.org/10.1007/978-981-13-9524-6_50
Download citation
DOI: https://doi.org/10.1007/978-981-13-9524-6_50
Published:
Publisher Name: Springer, Singapore
Print ISBN: 978-981-13-9523-9
Online ISBN: 978-981-13-9524-6
eBook Packages: Earth and Environmental ScienceEarth and Environmental Science (R0)