Abstract
This paper takes one electronics industry washing board room as the research object and designs a push–pull ventilation system as the protection measures of the washing board room. Using the simulation method, this paper studies the influence of the ratio of supply and discharge air volume (k) on the push–pull ventilation system and the protective effect of toluene. It is found that the protective effect is best when the k value was 2.5. The ventilation system after on-site reform, of which test results of wind speed and poison concentration are consistent with the simulation results, can effectively protect the health of workers.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Chen J, Yang B, Liang S et al (2018) Study on the performances of supply air for uniform air supply square hood by numerical simulation. Man Mach Environ Syst Eng 456:449–455 (2017)
Zhou Y, Liu X, Wang Y (2014) Influences of obstacles on aerodynamic characteristics of push–pull ventilation system. Ind Saf Environ Prot 40(7):40–42
Chen J, Zhang G, Li J et al (2014) Analysis and evaluation on occupational disease prevention facilities of the paint mixing room in pre evaluation of occupational hazards. J Saf Sci Technol 10(2):147–150
Marzal F, Gonzalez E, Minana A et al (2003) Methodologies for determining capture efficiencies in surface treatment tanks. AIHA J 64(5):604–608
Hughes RT (1990) An overview of push–pull ventilation characteristics. Appl Occup Env Hyg 5(3):156–161
Betta V, Cascetta F, Palombo A (2007) Push–pull ventilation system: a CFD approach for the performance analysis. Int J Ambient Energy 28(3):123–134
Huang RF, Chen JK, Hung WL (2013) Flow and containment characteristics of a sash-less, variable-height inclined air-curtain fume hood. Annu Occup hyg 57(7):934–952
Cao Y, Wang Y, Li C (2016) A field measurement study of a parallel-flow push–pull system for industrial ventilation applications. Int J Vent 15(2):167–181
Chen J, Jiang Z, Yang B et al (2012) Numerical simulation of spatial dust concentration distribution regularities in crushing chamber. J China Coal Soc 37(11):1865–1870
Suyan HE, Yingmin WANG, Yunfei LI (2002) Flow field test and simulation of a three-dimensional Aaberg exhaust hood. J Shang Hai Jiao Tong Univ 36(10):1492–1495
Jianwu Chen, Bin Yang, Shasha Liang, Menglu Lin, Lindong Liu (2016) Research on push–pull ventilation in electronics industry washing board room. Saf Health Inner 2:33–36
Hughes RT (1995) An overview of push–pull ventilation characteristics. Appl Occup Environ Hyg 5(3):156–161
Huebener David J, Hughes Robert T (1985) Development of push–pull ventilation. Am Ind Hyg Assoc J 46(5):262–267
Acknowledgements
This work was supported by the National key R&D Program of China (2016YFC0801700), and the basic research funding of China Academy of Safety Science and Technology (2019JBKY11, 2019JBKY04 and 2018JBKY01).
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2020 Springer Nature Singapore Pte Ltd.
About this paper
Cite this paper
Yang, B., Chen, J., Liang, S., Zhou, S., Sun, Y., Li, Y. (2020). Design and Application of a Ventilation System in a Washing Board Room Based on Numerical Simulation. In: Long, S., Dhillon, B. (eds) Man–Machine–Environment System Engineering . MMESE 2019. Lecture Notes in Electrical Engineering, vol 576. Springer, Singapore. https://doi.org/10.1007/978-981-13-8779-1_54
Download citation
DOI: https://doi.org/10.1007/978-981-13-8779-1_54
Published:
Publisher Name: Springer, Singapore
Print ISBN: 978-981-13-8778-4
Online ISBN: 978-981-13-8779-1
eBook Packages: Intelligent Technologies and RoboticsIntelligent Technologies and Robotics (R0)