Evaluation of Separation Gap between Multi-storey Buildings Subjected to Dynamic Seismic Load

  • Conference paper
  • First Online:
Advances in Structural Engineering and Rehabilitation

Abstract

During the earthquake, the structures are subjected to earthquake forces and the adjacent structure may collide with each other due to different dynamic characteristics. When building vibrates out of phase and separated gap between buildings are not sufficient to accommodate their relative motions, this can cause severe damage to the structures, and it is known as seismic pounding. Many times maintaining sufficient pounding gap between adjacent buildings becomes difficult due to site constraints. The present work evaluates the minimum separation gap required between high-rise buildings. Two high-rise building of 10 storeys and 15 storeys are modelled and analysed for dynamic time history analysis for the EI Centro ground motions, and minimum pounding gap between buildings has been discussed.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 129.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 169.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 169.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Abdel Raheem Shehata E (2014) Mitigation measures for earthquake induced pounding effects on seismic performance of adjacent buildings. Bull Earthq Eng 12(4):1705–1724

    Article  Google Scholar 

  2. Dogan M, Gunaydin A (2009) Pounding of adjacent RC buildings during seismic loads. J Eng Archit XXII(1)

    Google Scholar 

  3. Kawade AB Mr. Sahane Abhijeet A Seismic pounding effect in building. Amrutvahini college of engineering, Sangamner

    Google Scholar 

  4. Lin J-H, Weng C-C (2002) A study on seismic pounding probability of buildings in Taipei metropolitan area. J Chin Inst Eng 25(2):123–135

    Article  Google Scholar 

  5. Goltabar AM, Kami RS, Ebadi A (2008) Analyzing the effective parameters in pounding phenomenon between adjacent structure due to earthquake. The 14th world conference on earthquake engineering, pp. 12–17, Beijing, China

    Google Scholar 

  6. Raheem SEA (2006) Seismic pounding between adjacent building structures. Electron J Struct Eng 6:66–74

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Umesh Biradar .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2020 Springer Nature Singapore Pte Ltd.

About this paper

Check for updates. Verify currency and authenticity via CrossMark

Cite this paper

Sridevi, G., Biradar, U., Sudarshan, G., Shivaraj, A. (2020). Evaluation of Separation Gap between Multi-storey Buildings Subjected to Dynamic Seismic Load. In: Adhikari, S., Bhattacharjee, B., Bhattacharjee, J. (eds) Advances in Structural Engineering and Rehabilitation. Lecture Notes in Civil Engineering , vol 38. Springer, Singapore. https://doi.org/10.1007/978-981-13-7615-3_19

Download citation

  • DOI: https://doi.org/10.1007/978-981-13-7615-3_19

  • Published:

  • Publisher Name: Springer, Singapore

  • Print ISBN: 978-981-13-7614-6

  • Online ISBN: 978-981-13-7615-3

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics