Skip to main content

Smart Wearable SpO2 Monitor for Newborns

  • Conference paper
  • First Online:

Part of the book series: IFMBE Proceedings ((IFMBE,volume 71))

Abstract

Monitoring vital signs is a must in Neonatal Intensive Care Units. The objective of this work is to design and implement a neonatal pulse oximeter in an innovative form, easy to use in NICU (Neonatal Intensive Care Unit) or by parents at home, at an affordable price. Pulse oximetry is a method to measure oxygen saturation of blood (SaO2) and heart rate (HR); these parameters indicate the assessment of acid-base balance, if breathing is performed in an efficient manner, and if cellular metabolism is effective. For premature newborns or newborns on term the oxygen saturation decreases in case of intracranial hemorrhage, which is the major complication of a newborn, respiratory insufficiency due to insufficient development of the lungs, associated with respiratory pathology and heart failure. This is the reason why we designed an innovative pulse oximeter- that we called P-SOCK.

This is a preview of subscription content, log in via an institution.

Buying options

Chapter
USD   29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD   129.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD   169.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Learn about institutional subscriptions

References

  1. Ahrens, T.S., Ott, K.: Comparison of three new generation pulse oximeters in a medical intensive care unit. Crit. Care Med. 34(12), A85 (2006)

    Article  Google Scholar 

  2. Tin, Win, Lal, Mithilesh: Principles of pulse oximetry and its clinical application in neonatal medicine. Semin. Fetal Neonatal Med. 20, 192–197 (2015)

    Article  Google Scholar 

  3. Costin, H., Rotariu, C.: Electronică medicală—o abordare practică, p. 95. Editura U.M.F. Gr. T. Popa, Iaşi (2007)

    Google Scholar 

  4. Dănăilă, C.: Angela Dăscălescu și Ion Antohe. Hematologie clinică. Editura U.M.F. Gr. T. Popa, Iaşi (2017)

    Google Scholar 

  5. https://datasheets.maximintegrated.com/en/ds/MAX30100.pdf. Accessed in March 2018

  6. http://donis.ro/content/html/detalii_produs.php?a=0&id_produs=1451&id_categorie=29. Accessed in May 2018

  7. https://www.teachmemicro.com/arduino-bluetooth/. Accessed June 2018

  8. HC-05 Bluetooth Module User’s Manual V1.0

    Google Scholar 

Download references

Conflict of Interest

The authors declare that they have no conflict of interest.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to M. Datcu .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2019 Springer Nature Singapore Pte Ltd.

About this paper

Check for updates. Verify currency and authenticity via CrossMark

Cite this paper

Datcu, M., Luca, C., Corciova, C. (2019). Smart Wearable SpO2 Monitor for Newborns. In: Vlad, S., Roman, N. (eds) 6th International Conference on Advancements of Medicine and Health Care through Technology; 17–20 October 2018, Cluj-Napoca, Romania. IFMBE Proceedings, vol 71. Springer, Singapore. https://doi.org/10.1007/978-981-13-6207-1_7

Download citation

  • DOI: https://doi.org/10.1007/978-981-13-6207-1_7

  • Published:

  • Publisher Name: Springer, Singapore

  • Print ISBN: 978-981-13-6206-4

  • Online ISBN: 978-981-13-6207-1

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics